Literature DB >> 9291611

Visual signal detectability with two noise components: anomalous masking effects.

A E Burgess1, X Li, C K Abbey.   

Abstract

We measured human observers' detectability of aperiodic signals in noise with two components (white and low-pass Gaussian). The white-noise component ensured that the signal detection task was always noise limited rather than contrast limited (i.e., image noise was always much larger than observer internal noise). The low-pass component can be considered to be a statistically defined background. Contrast threshold elevation was not linearly related to the rms background contrast. Our results gave power-law exponents near 0.6, similar to that found for deterministic masking. The Fisher-Hotelling linear discriminant model assessed by Rolland and Barrett [J. Opt. Soc. Am. A 9, 649 (1992)] and the modified nonprewhitening matched filter model suggested by Burgess [J. Opt. Soc. Am. A 11, 1237 (1994)] for describing signal detection in statistically defined backgrounds did not fit our more precise data. We show that it is not possible to find any nonprewhitening model that can fit our data. We investigated modified Fisher-Hotelling models by using spatial-frequency channels, as suggested by Myers and Barrett [J. Opt. Soc. Am. A 4, 2447 (1987)]. Two of these models did give good fits to our data, which suggests that we may be able to do partial prewhitening of image noise.

Entities:  

Mesh:

Year:  1997        PMID: 9291611     DOI: 10.1364/josaa.14.002420

Source DB:  PubMed          Journal:  J Opt Soc Am A Opt Image Sci Vis        ISSN: 1084-7529            Impact factor:   2.129


  38 in total

1.  Task-based modeling and optimization of a cone-beam CT scanner for musculoskeletal imaging.

Authors:  P Prakash; W Zbijewski; G J Gang; Y Ding; J W Stayman; J Yorkston; J A Carrino; J H Siewerdsen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  Anthropomorphic model observer performance in three-dimensional detection task for low-contrast computed tomography.

Authors:  Alexandre Ba; Miguel P Eckstein; Damien Racine; Julien G Ott; Francis Verdun; Sabine Kobbe-Schmidt; François O Bochud
Journal:  J Med Imaging (Bellingham)       Date:  2015-12-29

3.  Adaptation and visual search in mammographic images.

Authors:  Elysse Kompaniez-Dunigan; Craig K Abbey; John M Boone; Michael A Webster
Journal:  Atten Percept Psychophys       Date:  2015-05       Impact factor: 2.199

4.  Comparison of model and human observer performance for detection and discrimination tasks using dual-energy x-ray images.

Authors:  Samuel Richard; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

5.  Cascaded systems analysis of noise and detectability in dual-energy cone-beam CT.

Authors:  Grace J Gang; Wojciech Zbijewski; J Webster Stayman; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

6.  Image covariance and lesion detectability in direct fan-beam x-ray computed tomography.

Authors:  Adam Wunderlich; Frédéric Noo
Journal:  Phys Med Biol       Date:  2008-04-18       Impact factor: 3.609

7.  Correlation between human detection accuracy and observer model-based image quality metrics in computed tomography.

Authors:  Justin Solomon; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2016-09-22

8.  Pattern recognition in correlated and uncorrelated noise.

Authors:  Brianna Conrey; Jason M Gold
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2009-11       Impact factor: 2.129

9.  Characterization of statistical prior image constrained compressed sensing. I. Applications to time-resolved contrast-enhanced CT.

Authors:  Pascal Theriault Lauzier; Guang-Hong Chen
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.071

Review 10.  Breast cancer imaging: a perspective for the next decade.

Authors:  Andrew Karellas; Srinivasan Vedantham
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.