Normal echocardiographic characteristics of the Sorin Bicarbon bileaflet prosthetic heart valve in the mitral and aortic positions.

L Badano1, R Mocchegiani, D Bertoli, G DeGaetano, L Carratino, L Pasetti, M Caudullo, A Budini, B Mannello, G Passerone.   

Abstract

Doppler echocardiographic characteristics of normally functioning Sorin Bicarbon prostheses were prospectively assessed in 226 consecutive patients (135 male and 91 female patients, mean age 61 +/- 10 years) with 233 valves in the mitral (n = 67) and aortic (n = 166) positions whose function was considered normal by clinical and echocardiographic evaluation. Patterns of "normal" transprosthetic leakage were assessed with transthoracic echocardiography in all valves and with transesophageal echocardiography in six selected mitral valve prostheses. For the mitral valve prostheses, we found that peak and mean gradient, as well as pressure half-time, were not significantly different in either the 25 or the 31 mm valves (median values from 15 to 10 mm Hg, from 4 to 4 mm Hg, and from 70 to 83 ms; p = Not significant for all). On transthoracic study, 12 patients (17%) with a Sorin Bicarbon valve in the mitral position showed minimal transprosthetic leakage. On transesophageal study, all patients showed a transprosthetic leakage whose spatial distribution had a complex pattern: in planes orthogonal to the leaflet axis, two to four jets arising from the hinge points and converging toward the center of the valve plane could be visualized; in planes parallel to the leaflet axis, there were three jets, the two lateral ones diverging and the central one perpendicular to the valve plane. For the aortic valve prostheses, there was a significant decrease in transprosthetic gradients and an increase in effective orifice areas as prosthesis size increased. Peak and mean gradients decreased from a median value of 25 and 13 mm Hg in the 19 mm valves to 9 and 5 mm Hg in the 29 mm valves, respectively. Effective prosthetic valve area calculated with the continuity equation increased from a median value of 0.97 cm2 for the 19 mm size valves to 3.45 cm2 for the 29 mm size. With analysis of variance, effective prosthetic aortic valve area differentiated various valve sizes (F = 40.9, p < 0.0001) better than peak (F = 10.3, p < 0.0001) or mean (F = 8.04, p < 0.0001) gradients alone did. Furthermore, effective prosthetic aortic valve area correlated better than peak and mean gradients with prosthetic size (r = 0.76, r = -0.45, and r = -0.39, respectively). On transthoracic study, 109 patients (66%) showed minimal transprosthetic leakage. These normal values, obtained in a large number of patients with normofunctioning mitral and aortic Sorin Bicarbon valves, may help to identify Sorin Bicarbon prosthesis dysfunction.

Entities:  

Mesh:

Year:  1997        PMID: 9282353     DOI: 10.1016/s0894-7317(97)70026-9

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  6 in total

1.  Clinical experience with the Bicarbon heart valve prosthesis.

Authors:  Yoshio Misawa; Tsutomu Saito; Hiroaki Konishi; Shin-Ichi Oki; Yuichiro Kaminishi; Yasuhito Sakano; Hideki Morita; Kei Aizawa
Journal:  J Cardiothorac Surg       Date:  2007-01-25       Impact factor: 1.637

2.  Stentless bioprostheses have ideal haemodynamics, even in the small aortic root.

Authors:  L H Baur; Y Houdas; K H Peels; J Braun; B van Straten; A Prat; A P Kappetein; M Wolters-Geldoff; E E van der Wall; A V Bruschke; H A Huysmans
Journal:  Int J Card Imaging       Date:  2000-10

Review 3.  Diagnostic evaluation of left-sided prosthetic heart valve dysfunction.

Authors:  Jesse Habets; Ricardo P Budde; Petr Symersky; Renee B van den Brink; Bas A de Mol; Willem P Mali; Lex A van Herwerden; Steven A Chamuleau
Journal:  Nat Rev Cardiol       Date:  2011-05-17       Impact factor: 32.419

4.  Early results of Bentall-type operations during the last 10 years: comparison of mechanical valves and stentless bioprostheses.

Authors:  Koki Nakamura; Tomohiro Asai; Mikiko Murakami; Yosuke Saitoh; Hiroki Yamaguchi
Journal:  Gen Thorac Cardiovasc Surg       Date:  2007-01

5.  Long-term experience with the Sorin Bicarbon and Edwards Mira mechanical valve prostheses in the mitral position.

Authors:  Toshihiro Fukui; Toshihiko Shibata; Yasuyuki Sasaki; Hidekazu Hirai; Manabu Motoki; Yosuke Takahashi; Shigefumi Suehiro
Journal:  Gen Thorac Cardiovasc Surg       Date:  2007-03

6.  Validation of methods for effective orifice area measurement of prosthetic valves by two-dimensional and Doppler echocardiography following transcatheter self-expanding aortic valve implantation.

Authors:  Ming-Hu Xiao; Yong-Jian Wu; Jing-Jin Wang; Guang-Yuan Song; Jian-De Wang; Zhen-Hui Zhu; Xu Wang; Zhen-Yan Zhao; Hao Wang
Journal:  J Geriatr Cardiol       Date:  2020-12-28       Impact factor: 3.327

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.