Molecular leakage at implant-abutment connection--in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetration.

Sönke Harder1, Birka Dimaczek, Yaha Açil, Hendrik Terheyden, Sandra Freitag-Wolf, Matthias Kern.   

Abstract

Microleakage has been discussed as a major contributing factor for inflammatory reactions at the implant-abutment connection. In previous studies, the tightness against corpuscular bodies (viable bacteria) has been successfully investigated under static and dynamic conditions. The aim of this study was to investigate the tightness against endotoxins of two implant systems (AstraTech and Ankylos) with conical internal connections under static conditions. The inner parts of eight implants of each system were inoculated with endotoxin. Implants were screwed together with the respective abutments and stored under isostatic conditions in a supernatant of pyrogen-free water for 168 h. Supernatant samples were taken after 5 min, 24 h, 72 h, and 168 h, and endotoxin contamination was determined by the amebocyte-lysate test. Only one implant in the AstraTech group showed no sign of endotoxin contamination after 168 h, while the other implants showed contamination after varying storage times, respectively. The implants in the Ankylos group showed endotoxin contamination after only 5 min of storage in the supernatant solution. The tested internal conical implant-abutment connections appear to be unable to prevent endotoxin leakage. In average, Astra implants showed a higher tightness than Ankylos implants.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19629543     DOI: 10.1007/s00784-009-0317-x

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  20 in total

1.  Design features that may influence bacterial plaque retention: a retrospective analysis of failed implants.

Authors:  A O'Mahony; S R MacNeill; C M Cobb
Journal:  Quintessence Int       Date:  2000-04       Impact factor: 1.677

2.  Persistent acute inflammation at the implant-abutment interface.

Authors:  N Broggini; L M McManus; J S Hermann; R U Medina; T W Oates; R K Schenk; D Buser; J T Mellonig; D L Cochran
Journal:  J Dent Res       Date:  2003-03       Impact factor: 6.116

3.  Microbial penetration along the implant components of the Brånemark system. An in vitro study.

Authors:  M Quirynen; C M Bollen; H Eyssen; D van Steenberghe
Journal:  Clin Oral Implants Res       Date:  1994-12       Impact factor: 5.977

4.  Microbial leakage and marginal fit of the implant-abutment interface.

Authors:  V K Jansen; G Conrads; E J Richter
Journal:  Int J Oral Maxillofac Implants       Date:  1997 Jul-Aug       Impact factor: 2.804

5.  Clottable protein in Limulus; its localization and kinetics of its coagulation by endotoxin.

Authors:  J Levin; F B Bang
Journal:  Thromb Diath Haemorrh       Date:  1968-03-31

6.  Bacterial colonization of the internal part of two-stage implants. An in vivo study.

Authors:  M Quirynen; D van Steenberghe
Journal:  Clin Oral Implants Res       Date:  1993-09       Impact factor: 5.977

7.  Evaluation of a chromogenic method for endotoxin measurement.

Authors:  M F Scully; Y M Newman; S E Clark; V V Kakkar
Journal:  Thromb Res       Date:  1980-10-15       Impact factor: 3.944

8.  An invertebrate coagulation system activated by endotoxin: evidence for enzymatic mediation.

Authors:  N S Young; J Levin; R A Prendergast
Journal:  J Clin Invest       Date:  1972-07       Impact factor: 14.808

9.  In vitro evaluation of the implant abutment connection sealing capability of different implant systems.

Authors:  P G Coelho; P Sudack; M Suzuki; K S Kurtz; G E Romanos; N R F A Silva
Journal:  J Oral Rehabil       Date:  2008-10-29       Impact factor: 3.837

Review 10.  Endotoxemia: methods of detection and clinical correlates.

Authors:  J C Hurley
Journal:  Clin Microbiol Rev       Date:  1995-04       Impact factor: 26.132

View more
  28 in total

1.  Implant adaptation of stock abutments versus CAD/CAM abutments: a radiographic and Scanning Electron Microscopy study.

Authors:  Davide Apicella; Mario Veltri; Nicoletta Chieffi; Antonella Polimeni; Agostino Giovannetti; Marco Ferrari
Journal:  Ann Stomatol (Roma)       Date:  2011-02-13

2.  Assessment of lipopolysaccharide microleakage at conical implant-abutment connections.

Authors:  Sönke Harder; Elgar Susanne Quabius; Lars Ossenkop; Matthias Kern
Journal:  Clin Oral Investig       Date:  2011-12-02       Impact factor: 3.573

3.  Evaluation of impression accuracy for a four-implant mandibular model--a digital approach.

Authors:  Michael Stimmelmayr; Kurt Erdelt; Jan-Frederik Güth; Arndt Happe; Florian Beuer
Journal:  Clin Oral Investig       Date:  2011-10-19       Impact factor: 3.573

4.  In vitro synchrotron-based radiography of micro-gap formation at the implant-abutment interface of two-piece dental implants.

Authors:  A Rack; T Rack; M Stiller; H Riesemeier; S Zabler; K Nelson
Journal:  J Synchrotron Radiat       Date:  2010-02-03       Impact factor: 2.616

5.  Peri-implantitis. Part 2: Prevention and maintenance of peri-implant health.

Authors:  A Alani; K Bishop
Journal:  Br Dent J       Date:  2014-09       Impact factor: 1.626

6.  Cumulative survival rate of Astra Tech implants: a retrospective analysis.

Authors:  Jung-Soo Kim; Joo-Yeon Sohn; Jung-Chul Park; Ui-Won Jung; Chang-Sung Kim; Jae-Hoon Lee; June-Sung Shim; Keun-Woo Lee; Seong-Ho Choi
Journal:  J Periodontal Implant Sci       Date:  2011-04-29       Impact factor: 2.614

7.  Clinical study evaluating the discrepancy of two different impression techniques of four implants in an edentulous jaw.

Authors:  Michael Stimmelmayr; Jan-Frederik Güth; Kurt Erdelt; Arndt Happe; Markus Schlee; Florian Beuer
Journal:  Clin Oral Investig       Date:  2012-12-06       Impact factor: 3.573

8.  Analysis of the intraimplant microflora of two-piece dental implants.

Authors:  Sönke Harder; Rainer Podschun; Livia Grancicova; Christian Mehl; Matthias Kern
Journal:  Clin Oral Investig       Date:  2012-09-08       Impact factor: 3.573

9.  Oral bacterial colonization on dental implants restored with titanium or zirconia abutments: 6-month follow-up.

Authors:  Alice Ramos de Freitas; Thalisson Saymo de Oliveira Silva; Ricardo Faria Ribeiro; Rubens Ferreira de Albuquerque Junior; Vinícius Pedrazzi; Cássio do Nascimento
Journal:  Clin Oral Investig       Date:  2018-01-18       Impact factor: 3.573

10.  Micro-leakage at the implant-abutment interface with different tightening torques in vitro.

Authors:  João Paulo da Silva-Neto; Marcel Santana Prudente; Thiago de Almeida Prado Naves Carneiro; Mauro Antônio de Arruda Nóbilo; Mario Paulo Amante Penatti; Flávio Domingues das Neves
Journal:  J Appl Oral Sci       Date:  2012 Sep-Oct       Impact factor: 2.698

View more