Literature DB >> 22238709

Implant adaptation of stock abutments versus CAD/CAM abutments: a radiographic and Scanning Electron Microscopy study.

Davide Apicella1, Mario Veltri, Nicoletta Chieffi, Antonella Polimeni, Agostino Giovannetti, Marco Ferrari.   

Abstract

INTRODUCTION: The study evaluated a null-hypothesis of no differences of fit between stock abutments and CAD/CAM titanium, gold sputtered and zirconia abutments when examined for radiographic adaptation and Scanning Electron Microcopy (SEM) at their inner aspect. The agreement between microscopic and radiographic fit was also assessed.
METHODS: Implants (Osseospeed, Astra Tech, Mölndal, Sweden) were connected to titanium abutments (Ti-design, Astra Tech, Mölndal, Sweden) (control group n=12), to stock zirconia abutments (Zir-design, Astra Tech) (group 1 n=12) and to third party zirconia abutments (Aadva Zr abutment, GC, Tokyo, Japan) as observed under SEM (JEOL JSM-6060LV, Tokyo, Japan). Two independent operators blindly evaluated the images, according to a three-score scale: perfect adaptation, no complete adaptation, and clear evidence of no adaptation. A Kruskal-Wallis test was applied to assess significant differences in adaptation scores between the groups.
RESULTS: All specimens showed precise SEM adaptation at all tested interfaces and no radiographically apparent gaps. No significant differences were found and therefore the null-hypothesis tested was accepted. Radiographic and SEM scores were in agreement. DISCUSSION: CAD/CAM titanium, gold sputtered and zirconia abutments and third-part CAD/CAM zirconia abutments show an adaptation to Astra Tech implants that is comparable to that of stock titanium and zirconia abutments. Clinicians might be able to verify such adaptation with an x-ray. In-vivo studies would be needed to evaluate the clinical outcome of CAD/CAM abutments.

Entities:  

Keywords:  abutment; interface; titanium; zirconia

Year:  2011        PMID: 22238709      PMCID: PMC3254378     

Source DB:  PubMed          Journal:  Ann Stomatol (Roma)        ISSN: 1824-0852


  19 in total

Review 1.  Implants and components: entering the new millennium.

Authors:  P P Binon
Journal:  Int J Oral Maxillofac Implants       Date:  2000 Jan-Feb       Impact factor: 2.804

2.  Peri-implant inflammation defined by the implant-abutment interface.

Authors:  N Broggini; L M McManus; J S Hermann; R Medina; R K Schenk; D Buser; D L Cochran
Journal:  J Dent Res       Date:  2006-05       Impact factor: 6.116

Review 3.  Current ceramic materials and systems with clinical recommendations: a systematic review.

Authors:  Heather J Conrad; Wook-Jin Seong; Igor J Pesun
Journal:  J Prosthet Dent       Date:  2007-11       Impact factor: 3.426

4.  The implant-abutment interface of alumina and zirconia abutments.

Authors:  Bulem Yüzügüllü; Mehmet Avci
Journal:  Clin Implant Dent Relat Res       Date:  2008-01-24       Impact factor: 3.932

5.  The effect of implant/abutment hexagonal misfit on screw joint stability.

Authors:  P P Binon
Journal:  Int J Prosthodont       Date:  1996 Mar-Apr       Impact factor: 1.681

6.  Radiographic verification of implant abutment seating.

Authors:  S M Cameron; A Joyce; J S Brousseau; M H Parker
Journal:  J Prosthet Dent       Date:  1998-03       Impact factor: 3.426

7.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

8.  Bacterial colonization of the internal part of two-stage implants. An in vivo study.

Authors:  M Quirynen; D van Steenberghe
Journal:  Clin Oral Implants Res       Date:  1993-09       Impact factor: 5.977

Review 9.  An overview of zirconia ceramics: basic properties and clinical applications.

Authors:  Paolo Francesco Manicone; Pierfrancesco Rossi Iommetti; Luca Raffaelli
Journal:  J Dent       Date:  2007-09-06       Impact factor: 4.379

10.  Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions: 4-year results of a prospective clinical study.

Authors:  Roland Glauser; Irena Sailer; Arnold Wohlwend; Stephan Studer; Monica Schibli; Peter Schärer
Journal:  Int J Prosthodont       Date:  2004 May-Jun       Impact factor: 1.681

View more
  2 in total

1.  Comparative evaluation of the wear resistance of two different implant abutment materials after cyclic loading - An in vitro study.

Authors:  Maniamuthu Ragupathi; Vallabh Mahadevan; N S Azhagarasan; Hariharan Ramakrishnan; S Jayakrishnakumar
Journal:  Contemp Clin Dent       Date:  2020-11-26

2.  Stock Versus CAD/CAM Customized Zirconia Implant Abutments - Clinical and Patient-Based Outcomes in a Randomized Controlled Clinical Trial.

Authors:  Ulf Schepke; Henny J A Meijer; Wouter Kerdijk; Gerry M Raghoebar; Marco Cune
Journal:  Clin Implant Dent Relat Res       Date:  2016-07-31       Impact factor: 3.932

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.