Bacterial contamination along implant-abutment interface in external and internal-hex dental implants.

Greison Rabelo de Oliveira1, Sergio Olate2, Leandro Pozzer3, Lucas Cavalieri-Pereira3, Jaime G Rodrigues-Chessa4, José Ricardo Albergaría-Barbosa3.   

Abstract

The aim of this research was to evaluate bacterial contamination along the implant-abutment interface in relation to the size of the interface. 80 brand name implants were used, 40 internal-hex and 40 external-hex. The implants were handled in a sterile atmosphere inside a box, where they were inoculated with 0.3 μl of the Streptococcus sanguis ATCC10556 bacterium in the interior and the abutment was immediately installed with a torque of 30 Ncm for the external-hex and 20 Ncm for the internal-hex; the system was included in an Eppendorf control for 30 seconds and then placed in an Eppendorf control for 30 days. The implants were removed and assessed under a scanning electron microscope while the Eppendorf controls were bred in blood agar to analyze the colonies formed. The data were analyzed using the Chi-squared, Kruskal-Wallis and Mann-Whitney tests, considering a value of p<0.05 to obtain statistical significance. Five implants were excluded due to probable external contamination. Microspaces of up to 86.8 μm were observed in the external-hex implants and up to 53.9 μm in the internal-hex implants with no significant differences between the different systems being observed (p>0.05). The contamination observed was produced mainly in the external-hex implants and statistically significant differences were observed between the different hex systems from the same company. No significant differences were observed between interface size and bacterial contamination. Within our limitations, there was no relation between the size of the implant-abutment interface and bacterial contamination with Streptococcus sanguis ATCC10556.

Entities:  

Keywords:  Implant interface; bacterial contamination; dental implant

Year:  2014        PMID: 24753751      PMCID: PMC3992396     

Source DB:  PubMed          Journal:  Int J Clin Exp Med        ISSN: 1940-5901


  26 in total

1.  Loss of crestal bone around dental implants: a retrospective study.

Authors:  D P Callan; A O'Mahony; C M Cobb
Journal:  Implant Dent       Date:  1998       Impact factor: 2.454

2.  Preload loss and bacterial penetration on different implant-abutment connection systems.

Authors:  Antônio Pedro Ricomini Filho; Frederico Silva de Freitas Fernandes; Fabiana Gouveia Straioto; Wander José da Silva; Altair Antoninha Del Bel Cury
Journal:  Braz Dent J       Date:  2010

Review 3.  Treatment of peri-implantitis: surgical therapeutic approaches based on peri-implantitis defects.

Authors:  Stefano Parma-Benfenati; Marisa Roncati; Carlo Tinti
Journal:  Int J Periodontics Restorative Dent       Date:  2013 Sep-Oct       Impact factor: 1.840

4.  Evaluation of the implant-connection interface using scanning electron microscopy.

Authors:  G M Vidigal; A B Novaes; O Chevitarese; R R de Avillez; M Groisman
Journal:  Braz Dent J       Date:  1995

5.  Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys.

Authors:  F Isidor
Journal:  Clin Oral Implants Res       Date:  1996-06       Impact factor: 5.977

6.  Analysis of the bacterial seal at the implant-abutment interface in external-hexagon and Morse taper-connection implants: an in vitro study using a new methodology.

Authors:  Mario Eduardo Jaworski; Ana Cláudia Moreira Melo; Cyntia Maria Telles Picheth; Ivete Aparecida de Mattias Sartori
Journal:  Int J Oral Maxillofac Implants       Date:  2012 Sep-Oct       Impact factor: 2.804

7.  Bacterial colonization of the internal part of two-stage implants. An in vivo study.

Authors:  M Quirynen; D van Steenberghe
Journal:  Clin Oral Implants Res       Date:  1993-09       Impact factor: 5.977

8.  Microbiological features of stable osseointegrated implants used as abutments for overdentures.

Authors:  A Mombelli; R Mericske-Stern
Journal:  Clin Oral Implants Res       Date:  1990-12       Impact factor: 5.977

9.  Evaluation of bacterial adhesion on machined titanium, Osseotite® and Nanotite® discs.

Authors:  Ruggero Rodriguez y Baena; Carla Renata Arciola; Laura Selan; Rosalia Battaglia; Marcello Imbriani; Silvana Rizzo; Livia Visai
Journal:  Int J Artif Organs       Date:  2012-10       Impact factor: 1.595

10.  Failing factors associated with osseointegrated dental implant loss.

Authors:  Claudia Cristina Montes; Fabiano Alvim Pereira; Geninho Thomé; Edson Durval Menezes Alves; Rogéria Vieira Acedo; José Renato de Souza; Ana Cláudia Moreira Melo; Paula Cristina Trevilatto
Journal:  Implant Dent       Date:  2007-12       Impact factor: 2.454

View more
  2 in total

1.  The effect of dynamic loading on bacterial microleakage of the dental implant fixture-abutment interface: An in vitro study.

Authors:  Mehrak Amjadi; Azadeh Khajavi; Navid Youssefi; Negar Barjini; Zahra Kazemi
Journal:  J Indian Prosthodont Soc       Date:  2021 Oct-Dec

2.  In Vitro Bacterial Leakage at the Implant-Abutment Connection of Two Dental Implant Systems with Internal Connection.

Authors:  Azadeh Khajavi; Shabnam Mohseni; Amir Peymani; Mehrak Amjadi
Journal:  Front Dent       Date:  2020-12-08
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.