Literature DB >> 26174348

Determination of fluid leakages in the different screw-retained implant-abutment connections in a mechanical artificial mouth.

D Martin-Gili1, M Molmeneu, M Fernandez, M Punset, Ll Giner, J Armengou, F Javier Gil.   

Abstract

This study shows the potential risk of microfiltration between two different types of implant-abutment connections screwed at 45 Ncm: external and internal. For the first time the use of a mechanical artificial mouth is used with the values (compression and torsion loads with a frequency of 2 Hz) of the human chewing. The mechanical tests were performed with an artificial saliva at 37°C. The microgap in the connection was measured by an Image Analysis software incorporated in a high resolution scanning electron microscopy. Implant connections were filled with methylene blue by using self-adjustable precision pipettes and the quantity of leakage was determined by high sensitivity spectometry. We showed that the internal connection has lower microgaps compared to the external ones and these microgaps increased with the number of mechanical cycles. The leakage of methylene blue was higher when the external connection was performed. Microgaps and the influence of the mechanical loads are very important for the long-term behavior avoiding the bacteria colonization in the dental implants. These aspects should be known by the implantologists.

Entities:  

Mesh:

Year:  2015        PMID: 26174348     DOI: 10.1007/s10856-015-5544-x

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  25 in total

1.  Persistent acute inflammation at the implant-abutment interface.

Authors:  N Broggini; L M McManus; J S Hermann; R U Medina; T W Oates; R K Schenk; D Buser; J T Mellonig; D L Cochran
Journal:  J Dent Res       Date:  2003-03       Impact factor: 6.116

2.  Leakage of saliva through the implant-abutment interface: in vitro evaluation of three different implant connections under unloaded and loaded conditions.

Authors:  Cássio do Nascimento; Paola Kirsten Miani; Vinícius Pedrazzi; Reginaldo Bruno Gonçalves; Ricardo Faria Ribeiro; Adriana Cláudia Lapria Faria; Ana Paula Macedo; Rubens Ferreira de Albuquerque
Journal:  Int J Oral Maxillofac Implants       Date:  2012 May-Jun       Impact factor: 2.804

Review 3.  Marginal bone level changes at dental implants after 5 years in function: a meta-analysis.

Authors:  Lars Laurell; Dan Lundgren
Journal:  Clin Implant Dent Relat Res       Date:  2011-03       Impact factor: 3.932

4.  Analysis of the bacterial seal at the implant-abutment interface in external-hexagon and Morse taper-connection implants: an in vitro study using a new methodology.

Authors:  Mario Eduardo Jaworski; Ana Cláudia Moreira Melo; Cyntia Maria Telles Picheth; Ivete Aparecida de Mattias Sartori
Journal:  Int J Oral Maxillofac Implants       Date:  2012 Sep-Oct       Impact factor: 2.804

5.  Bacterial colonization of the internal part of two-stage implants. An in vivo study.

Authors:  M Quirynen; D van Steenberghe
Journal:  Clin Oral Implants Res       Date:  1993-09       Impact factor: 5.977

6.  Bone reactions to longstanding functional load at implants: an experimental study in dogs.

Authors:  T Berglundh; I Abrahamsson; J Lindhe
Journal:  J Clin Periodontol       Date:  2005-09       Impact factor: 8.728

7.  Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man.

Authors:  T Albrektsson; P I Brånemark; H A Hansson; J Lindström
Journal:  Acta Orthop Scand       Date:  1981

8.  Bacterial colonization of the dental implant fixture-abutment interface: an in vitro study.

Authors:  Michael Tesmer; Shannon Wallet; Theofilos Koutouzis; Tord Lundgren
Journal:  J Periodontol       Date:  2009-12       Impact factor: 6.993

9.  In vitro evaluation of the implant abutment connection sealing capability of different implant systems.

Authors:  P G Coelho; P Sudack; M Suzuki; K S Kurtz; G E Romanos; N R F A Silva
Journal:  J Oral Rehabil       Date:  2008-10-29       Impact factor: 3.837

10.  Different types of inflammatory reactions in peri-implant soft tissues.

Authors:  I Ericsson; L G Persson; T Berglundh; C P Marinello; J Lindhe; B Klinge
Journal:  J Clin Periodontol       Date:  1995-03       Impact factor: 8.728

View more
  2 in total

1.  Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit.

Authors:  Jorge Vélez; Jesús Peláez; Carlos López-Suárez; Rubén Agustín-Panadero; Celia Tobar; María J Suárez
Journal:  J Clin Med       Date:  2020-07-24       Impact factor: 4.241

2.  Microleakage assessment of CAD-CAM Cobalt-Chrome and Zirconia abutments on a conical connection dental implant: A comparative in vitro study.

Authors:  Pedro Molinero-Mourelle; Andrea Roccuzzo; Burak Yilmaz; Walter Yu Hang Lam; Edmond H N Pow; Jaime Del Río Highsmith; Miguel Gómez-Polo
Journal:  Clin Oral Implants Res       Date:  2022-07-21       Impact factor: 5.021

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.