Literature DB >> 9243381

Flow-independent angiography for peripheral vascular disease: initial in-vivo results.

R Gronas1, P G Kalman, D S Kucey, G A Wright.   

Abstract

Flow-independent angiography (FIA), an approach that isolates arterial blood using MR relaxation characteristics rather than flow effects, was evaluated for application in peripheral vascular disease (PVD). First, pilot studies were conducted in which FIA coronal projection images were obtained from controls and symptomatic patients with PVD to assess clinical utility. All control images corresponded to the expected leg arterial anatomy with little interference from deep veins (one of five) and muscle (zero of five). Superficial venous signal was less well suppressed in comparison to deep veins (four of five). Images of symptomatic patients were less consistent with difficulty suppressing muscle and deep venous signal in some cases and edema when present. We then compared T2 values for muscle (T2m, tibialis anterior), arterial blood (femoral and popliteal arteries), and venous blood (femoral, popliteal, and saphenous veins) in controls (n = 8) and symptomatic patients with intermittent claudication (n = 5) or ischemic rest pain (n = 7). Changes in T2 measurements of various tissues accounted for poorer contrast in symptomatic patients. Patients with ischemic rest pain had significantly higher T2m compared with controls (T2m = 39.3 +/- 2.1 (1 standard error of the mean [SEM]) versus 30.9 +/- .4, P < .01). For all measurements, other than saphenous vein, variances were greater in symptomatic patients. To realize the inherent advantages of FIA for this clinical application, additional work on suppression of signals from muscle, veins, and edema is required. One promising approach involves shifting from projection images to three-dimensional acquisitions for improved tissue suppression.

Entities:  

Mesh:

Year:  1997        PMID: 9243381     DOI: 10.1002/jmri.1880070405

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  7 in total

Review 1.  Coronary Artery Plaque Imaging.

Authors:  Yibin Xie; Hang Jin; Mengsu Zeng; Debiao Li
Journal:  Curr Atheroscler Rep       Date:  2017-09       Impact factor: 5.113

2.  Three-dimensional fluid-suppressed T2-prep flow-independent peripheral angiography using balanced SSFP.

Authors:  Neal K Bangerter; Tolga Cukur; Brian A Hargreaves; Bob S Hu; Jean H Brittain; Danny Park; Garry E Gold; Dwight G Nishimura
Journal:  Magn Reson Imaging       Date:  2011-06-25       Impact factor: 2.546

3.  Simultaneous fat suppression and band reduction with large-angle multiple-acquisition balanced steady-state free precession.

Authors:  Brady Quist; Brian A Hargreaves; Tolga Cukur; Glen R Morrell; Garry E Gold; Neal K Bangerter
Journal:  Magn Reson Med       Date:  2011-10-28       Impact factor: 4.668

4.  Improving non-contrast-enhanced steady-state free precession angiography with compressed sensing.

Authors:  Tolga Cukur; Michael Lustig; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

5.  3D noncontrast MR angiography of the distal lower extremities using flow-sensitive dephasing (FSD)-prepared balanced SSFP.

Authors:  Zhaoyang Fan; John Sheehan; Xiaoming Bi; Xin Liu; James Carr; Debiao Li
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

6.  Non-contrast-enhanced flow-independent peripheral MR angiography with balanced SSFP.

Authors:  Tolga Cukur; Jin H Lee; Neal K Bangerter; Brian A Hargreaves; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2009-06       Impact factor: 4.668

7.  Non-contrast-enhanced peripheral angiography using a sliding interleaved cylinder acquisition.

Authors:  Kie Tae Kwon; Adam B Kerr; Holden H Wu; Bob S Hu; Jean H Brittain; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2014-09-09       Impact factor: 4.668

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.