Literature DB >> 22854112

Comparison of lateral thermal damage of the human peritoneum using monopolar diathermy, Harmonic scalpel and LigaSure.

Nikica Družijanić1, Zenon Pogorelić, Zdravko Perko, Ivana Mrklić, Snježana Tomić.   

Abstract

BACKGROUND: New hemostatic technologies are often employed in open and laparoscopic surgery to reduce duration of surgery and complications. Monopolar diathermy, Harmonic scalpel and LigaSure are routinely used in open and laparoscopic surgery for tissue cutting and hemostasis. We compared lateral thermal damage following in vivo application of 3 commonly used instruments.
METHODS: We used monopolar diathermy, Harmonic scalpel and LigaSure to coagulate and divide the peritoneum of patients who underwent median laparotomy. After anesthesia, median supraumbilical laparotomy was performed, and the peritoneum of each patient was coagulated using different devices. Using light microscopy and morphometric imaging analysis, the width of tissue lateral thermal damage was measured from the point of the peritoneal incision.
RESULTS: We included 100 patients in our study. After a peritoneal incision, the mean lateral thermal damage of monopolar diathermy, Harmonic scalpel (output power 3), Harmonic scalpel (output power 5) and LigaSure were 215.79 μm, 90.42 μm, 127.48 μm and 144.18 μm, respectively.
CONCLUSION: The degree of lateral thermal spread varied by instrument type, power setting and application time. LigaSure and Harmonic scalpel were the safest and most efficient methods of tissue coagulation. Monopolar diathermy resulted in the greatest degree of thermal damage in tissues.

Entities:  

Mesh:

Year:  2012        PMID: 22854112      PMCID: PMC3468644          DOI: 10.1503/cjs.000711

Source DB:  PubMed          Journal:  Can J Surg        ISSN: 0008-428X            Impact factor:   2.089


  18 in total

1.  Comparison of tissue injury between laparosonic coagulating shears and electrosurgical scissors in the sheep model.

Authors:  A Kwok; D Nevell; A Ferrier; N Graf; A Lam; R Ford
Journal:  J Am Assoc Gynecol Laparosc       Date:  2001-08

2.  Comparison of monopolar electrocoagulation, bipolar electrocoagulation, Ultracision, and Ligasure.

Authors:  Theodore Diamantis; Michael Kontos; Antonios Arvelakis; Spiridon Syroukis; Dimitris Koronarchis; Apostolos Papalois; Emmanuel Agapitos; Elias Bastounis; Andreas C Lazaris
Journal:  Surg Today       Date:  2006       Impact factor: 2.549

Review 3.  Principles and initial experience of a new device for dissection and hemostasis.

Authors:  A S Gözen; D Teber; J J Rassweiler
Journal:  Minim Invasive Ther Allied Technol       Date:  2007       Impact factor: 2.442

4.  Exploring new technologies to facilitate laparoscopic surgery: creating intestinal anastomoses without sutures or staples, using a radio-frequency-energy-driven bipolar fusion device.

Authors:  J F Smulders; I H J T de Hingh; J Stavast; J J Jackimowicz
Journal:  Surg Endosc       Date:  2007-05-19       Impact factor: 4.584

5.  Laparosonic coagulating shears: alternative method of hemostatic control of unsupported tissue.

Authors:  D M Hoenig; C A Chrostek; J F Amaral
Journal:  J Endourol       Date:  1996-10       Impact factor: 2.942

6.  Proximity injury by the ultrasonically activated scalpel during dissection.

Authors:  K M Kadesky; B Schopf; J F Magee; G K Blair
Journal:  J Pediatr Surg       Date:  1997-06       Impact factor: 2.545

7.  High-burst-strength, feedback-controlled bipolar vessel sealing.

Authors:  J S Kennedy; P L Stranahan; K D Taylor; J G Chandler
Journal:  Surg Endosc       Date:  1998-06       Impact factor: 4.584

8.  LigaSure compared with ligatures and endoclips in experimental appendectomy: how safe is it?

Authors:  Levent Elemen; Yusufhan Yazir; Melih Tugay; Alper Akay; Seval Aydin; Karolin Yanar; Süreyya Ceylan
Journal:  Pediatr Surg Int       Date:  2010-02-07       Impact factor: 1.827

9.  Lateral thermal damage to rat abdominal wall after harmonic scalpel application.

Authors:  Z Perko; Z Pogorelić; K Bilan; S Tomić; K Vilović; D Krnić; N Druzijanić; D Kraljević; J Juricić
Journal:  Surg Endosc       Date:  2005-12-05       Impact factor: 4.584

10.  Comparison of coagulation modalities in surgery.

Authors:  I I Lantis JC; F M Durville; R Connolly; S D Schwaitzberg
Journal:  J Laparoendosc Adv Surg Tech A       Date:  1998-12       Impact factor: 1.878

View more
  18 in total

Review 1.  Surgical Efficacy Among Laparoscopic Ultrasonic Dissectors: Are We Advancing Safely? A Review of Literature.

Authors:  Rajesh Devassy; Sreelatha Gopalakrishnan; Rudy Leon De Wilde
Journal:  J Obstet Gynaecol India       Date:  2015-09-14

2.  Safety and efficacy of LigaSure usage in pancreaticoduodenectomy.

Authors:  Oliver S Eng; Julie Goswami; Dirk Moore; Chunxia Chen; Jennifer Brumbaugh; Christopher J Gannon; David A August; Darren R Carpizo
Journal:  HPB (Oxford)       Date:  2013-06-19       Impact factor: 3.647

3.  Lateral thermal spread induced by energy devices: a porcine model to evaluate the influence on the recurrent laryngeal nerve.

Authors:  Masaru Hayami; Masayuki Watanabe; Shinji Mine; Yu Imamura; Akihiko Okamura; Masami Yuda; Kotaro Yamashita; Tasuku Toihata; Yoshiaki Shoji; Naoki Ishizuka
Journal:  Surg Endosc       Date:  2019-03-07       Impact factor: 4.584

Review 4.  Laparoscopic pancreaticoduodenectomy: a systematic literature review.

Authors:  Ugo Boggi; Gabriella Amorese; Fabio Vistoli; Fabio Caniglia; Nelide De Lio; Vittorio Perrone; Linda Barbarello; Mario Belluomini; Stefano Signori; Franco Mosca
Journal:  Surg Endosc       Date:  2014-08-15       Impact factor: 4.584

5.  Ultrasonic versus monopolar energy-based surgical devices in terms of surgical smoke and lateral thermal damage (ULMOST): a randomized controlled trial.

Authors:  Chahien Choi; In-Gu Do; Taejong Song
Journal:  Surg Endosc       Date:  2018-04-09       Impact factor: 4.584

6.  Effect of energy-based devices on voice quality after total thyroidectomy.

Authors:  Server Sezgin Uludag; Serkan Teksoz; Akif Enes Arikan; Ozge Tarhan; Haydar Murat Yener; Murat Ozcan; Whitney Liddy; Gregory William Randolph
Journal:  Eur Arch Otorhinolaryngol       Date:  2017-02-25       Impact factor: 2.503

7.  A new approach to laparoscopic appendectomy in children-clipless/sutureless Harmonic scalpel laparoscopic appendectomy.

Authors:  Zenon Pogorelić; Vedran Beara; Miro Jukić; Hayssam Rashwan; Tomislav Šušnjar
Journal:  Langenbecks Arch Surg       Date:  2021-11-29       Impact factor: 3.445

8.  Tissue effects in vessel sealing and transection from an ultrasonic device with more intelligent control of energy delivery.

Authors:  Duan Broughton; Alissa L Welling; Emily H Monroe; Kristen Pirozzi; John B Schulte; Jeffrey W Clymer
Journal:  Med Devices (Auckl)       Date:  2013-09-16

Review 9.  Performance of Harmonic devices in surgical oncology: an umbrella review of the evidence.

Authors:  Hang Cheng; Jeffrey W Clymer; Behnam Sadeghirad; Nicole C Ferko; Chris G Cameron; Joseph F Amaral
Journal:  World J Surg Oncol       Date:  2018-01-04       Impact factor: 2.754

10.  A Model to Study Thermal Energy Delivery to the Choroid: A Comparison of Surgical Devices.

Authors:  Stephen A LoBue; Prashant Tailor; Jarel K Gandhi; Paul Loftness; Timothy W Olsen
Journal:  Transl Vis Sci Technol       Date:  2018-12-28       Impact factor: 3.283

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.