Literature DB >> 9194320

A comparison of the components of the multifocal and full-field ERGs.

D C Hood1, W Seiple, K Holopigian, V Greenstein.   

Abstract

The multi-input technique of Sutter and Tran (1992) yields multiple focal ERGs. The purpose here was to compare the components of this multifocal ERG to the components of the standard, full-field ERG. To record multifocal ERGs, an array of 103 hexagons was displayed on a monitor. Full-field (Ganzfeld) ERGs were elicited by flashes presented upon steady background fields. The latencies of two prominent subcomponents of the full-field ERG were altered by varying the intensity of the incremental flash or the intensity of the background field. By showing that similar manipulations of the multi-input parameters produce similar changes in latency, we were able to relate the components of the multifocal ERG to the components of the full-field ERG. The biphasic responses of the multifocal ERG appear to be generated by the same cells generating the a-wave and positive peaks of the full-field cone ERG.

Entities:  

Mesh:

Year:  1997        PMID: 9194320     DOI: 10.1017/s0952523800012190

Source DB:  PubMed          Journal:  Vis Neurosci        ISSN: 0952-5238            Impact factor:   3.241


  57 in total

1.  Impact of notch filter use on waveforms of First- and Second-Order-Kernel responses from multifocal ERGs.

Authors:  M Bock; C Gerth; B Lorenz
Journal:  Doc Ophthalmol       Date:  2000-11       Impact factor: 2.379

2.  Continuous monitoring of the stimulated area in multifocal ERG.

Authors: 
Journal:  Doc Ophthalmol       Date:  2000       Impact factor: 2.379

3.  Multifocal ERG and VEP responses and visual fields: comparing disease-related changes.

Authors:  D C Hood; X Zhang
Journal:  Doc Ophthalmol       Date:  2000       Impact factor: 2.379

4.  Distribution of oscillatory components in the central retina.

Authors:  M A Bearse; Y Shimada; E E Sutter
Journal:  Doc Ophthalmol       Date:  2000       Impact factor: 2.379

5.  The interpretation of multifocal binary kernels.

Authors:  E Sutter
Journal:  Doc Ophthalmol       Date:  2000       Impact factor: 2.379

6.  Clinical applications of multifocal electroretinography.

Authors:  U Kretschmann; M Bock; R Gockeln; E Zrenner
Journal:  Doc Ophthalmol       Date:  2000       Impact factor: 2.379

7.  Assessment of local cone on- and off-pathway function using multifocal ERG technique.

Authors:  M Kondo; Y Miyake
Journal:  Doc Ophthalmol       Date:  2000       Impact factor: 2.379

8.  Multifocal electroretinogram: age-related changes for different luminance levels.

Authors:  Christina Gerth; Susan M Garcia; Lei Ma; John L Keltner; John S Werner
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2002-02-19       Impact factor: 3.117

9.  Topography of the multifocal electroretinogram.

Authors:  W A Verdon; G Haegerstrom-Portnoy
Journal:  Doc Ophthalmol       Date:  1998       Impact factor: 2.379

10.  Effects of APB, PDA, and TTX on ERG responses recorded using both multifocal and conventional methods in monkey. Effects of APB, PDA, and TTX on monkey ERG responses.

Authors:  William A Hare; Hau Ton
Journal:  Doc Ophthalmol       Date:  2002-09       Impact factor: 2.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.