Tensile strength of the cement-bone interface depends on the amount of bone interdigitated with PMMA cement.

K A Mann1, D C Ayers, F W Werner, R J Nicoletta, M D Fortino.   

Abstract

An experimental investigation was performed to (1) determine the general mechanical behavior and in particular, the post-yield behavior of the cement-bone interface under tensile loading, (2) determine where interface failure occurs, and (3) determine if the mechanical properties of the interface could be related to the density of bone at the interface and/or the amount of cement-bone interdigitation. Seventy-one cement-bone test specimens were machined from human proximal femurs that had been broached and cemented using contemporary cementing techniques. The amount of cement-bone interdigitation was documented and the quantitative computed tomography equivalent mineral density (QCT density) of the bone with cement was measured. Specimens were loaded to failure in tension under displacement control and exhibited linear elastic behavior with some reduction in stiffness until the peak tensile stress was reached (1.28 +/- 0.79 MPa). A substantial amount of strain softening (negative tangent stiffness) with an exponential-type decay was found after the peak stress and continued until there was complete debonding of the specimens (at 0.93 +/- 0.44 mm displacement). Interfacial failure most often occurred at the extent of cement penetration into the bone (56% of specimens) or with small spicules of cement left in the bone (38% of specimens). The results showed that the post-yield tensile behavior contributes substantially to the energy required to cause failure of the cement-bone interface, but the post-yield behavior was not well correlated with the amount of interdigitation or density of bone. Linear regression analysis revealed a moderate (r2 = 0.499, p < 0.0001) positive relationship between the tensile strength of the cement-bone interface and the quantity of bone interdigitated with the cement.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9075001     DOI: 10.1016/s0021-9290(96)00164-9

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  31 in total

1.  Coordinating retrieval and register studies improves postmarket surveillance.

Authors:  Peter Ellison; Geir Hallan; Paul Johan Høl; Nils Roar Gjerdet; Leif I Havelin
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

2.  Pulsed lavage improves fixation strength of cemented tibial components.

Authors:  Ulf J Schlegel; Jan Siewe; Karl S Delank; Peer Eysel; Klaus Püschel; Michael M Morlock; Anne Gebert de Uhlenbrock
Journal:  Int Orthop       Date:  2010-10-16       Impact factor: 3.075

3.  The influence of surface topography on wear debris generation at the cement/bone interface under cyclic loading.

Authors:  Kirk A Stoffel; Dongliang T Yang; Dwayne Arola
Journal:  J Mater Sci Mater Med       Date:  2007-10-13       Impact factor: 3.896

4.  Static shear strength between polished stem and seven commercial acrylic bone cements.

Authors:  Hongyu Zhang; Leigh Brown; Liam Blunt
Journal:  J Mater Sci Mater Med       Date:  2007-07-10       Impact factor: 3.896

5.  Experimental micromechanics of the cement-bone interface.

Authors:  Kenneth A Mann; Mark A Miller; Richard J Cleary; Dennis Janssen; Nico Verdonschot
Journal:  J Orthop Res       Date:  2008-06       Impact factor: 3.494

6.  Pulsed lavage reduces the incidence of radiolucent lines under the tibial tray of Oxford unicompartmental knee arthroplasty: pulsed lavage versus syringe lavage.

Authors:  Michael Clarius; Christian Hauck; Joern B Seeger; Andrew James; David W Murray; Peter R Aldinger
Journal:  Int Orthop       Date:  2009-02-14       Impact factor: 3.075

7.  Subject-specific planning of femoroplasty: a combined evolutionary optimization and particle diffusion model approach.

Authors:  Ehsan Basafa; Mehran Armand
Journal:  J Biomech       Date:  2014-05-14       Impact factor: 2.712

8.  Effect of hand packing versus cement gun pressurization on cement mantle in total knee arthroplasty.

Authors:  Michael Kopec; Joseph C Milbrandt; Todd Duellman; Doug Mangan; D Gordon Allan
Journal:  Can J Surg       Date:  2009-12       Impact factor: 2.089

9.  In vivo loss of cement-bone interlock reduces fixation strength in total knee arthroplasties.

Authors:  Jacklyn R Goodheart; Mark A Miller; Kenneth A Mann
Journal:  J Orthop Res       Date:  2014-04-29       Impact factor: 3.494

10.  Polymethylmethacrylate bone cements and additives: A review of the literature.

Authors:  Manit Arora; Edward Ks Chan; Sunil Gupta; Ashish D Diwan
Journal:  World J Orthop       Date:  2013-04-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.