Literature DB >> 9029302

Effects of cement creep on stem subsidence and stresses in the cement mantle of a total hip replacement.

Z Lu1, H McKellop.   

Abstract

In cemented total hip prostheses, the role of creep of the acrylic cement (polymethyl methacrylate, [PMMA]) in increasing or decreasing the chance of failure of the cement mantle is a subject of ongoing controversy. In the present study we used a three-dimensional finite-element model of a cemented stem to assess the influence of cement creep on subsidence of the stem, and on the stress and strain in the cement under cyclic load, both in the short and long term. The cement layer was assigned the shear and bulk creep moduli of Zimmer regular PMMA cement, which were obtained experimentally. The stem-cement interface was modeled either as (1) completely bonded, (2) completely debonded with friction, or (3) completely debonded and frictionless. Under the cyclic load some cement creep occurred with all three bonding conditions, allowing additional subsidence of the stem and a decrease in the stress components within the cement. During the unloaded period the full recovery of the preload conditions could be reached with the completely bonded and with the frictionless interfaces. With the frictional interface there was residual cement creep, residual stresses within the cement, and residual subsidence of the stem during the unloaded period; however, the reduction of the stress was at most 13% and the subsidence was about 0.46 mm. The much larger subsidence of debonded stems that is often observed clinically might be attributed to the factors which were not included in the present model, such as circumferential bone remodeling.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9029302     DOI: 10.1002/(sici)1097-4636(199702)34:2<221::aid-jbm11>3.0.co;2-l

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  6 in total

1.  Creep behavior comparison of CMW1 and palacos R-40 clinical bone cements.

Authors:  C Liu; S M Green; N D Watkins; P J Gregg; A W McCaskie
Journal:  J Mater Sci Mater Med       Date:  2002-11       Impact factor: 3.896

2.  Factors affecting the mechanical and viscoelastic properties of acrylic bone cement.

Authors:  A J C Lee; R S M Ling; Sabina Gheduzzi; Jean-Pierre Simon; R J Renfro
Journal:  J Mater Sci Mater Med       Date:  2002-08       Impact factor: 3.896

3.  Dynamic creep and mechanical characteristics of SmartSet GHV bone cement.

Authors:  C Z Liu; S M Green; N D Watkins; D Baker; A W McCaskie
Journal:  J Mater Sci Mater Med       Date:  2005-02       Impact factor: 3.896

4.  The relationship between stem subsidence and improvement in the radiolucency in polished tapered stems.

Authors:  Ayumi Kaneuji; Tanzo Sugimori; Toru Ichiseki; Kiyokazu Fukui; Kengo Yamada; Tadami Matsumoto
Journal:  Int Orthop       Date:  2006-04-14       Impact factor: 3.075

5.  The effect of cement creep and cement fatigue damage on the micromechanics of the cement-bone interface.

Authors:  Daan Waanders; Dennis Janssen; Kenneth A Mann; Nico Verdonschot
Journal:  J Biomech       Date:  2010-08-07       Impact factor: 2.712

6.  Stem subsidence of polished and rough double-taper stems: in vitro mechanical effects on the cement-bone interface.

Authors:  Ayumi Kaneuji; Kengo Yamada; Kenichi Hirosaki; Masahiro Takano; Tadami Matsumoto
Journal:  Acta Orthop       Date:  2009-06       Impact factor: 3.717

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.