Literature DB >> 16614823

The relationship between stem subsidence and improvement in the radiolucency in polished tapered stems.

Ayumi Kaneuji1, Tanzo Sugimori, Toru Ichiseki, Kiyokazu Fukui, Kengo Yamada, Tadami Matsumoto.   

Abstract

We studied the relationship between stem subsidence and improvement in the initial radiolucency at the bone-cement interface in polished- and rough-surface stems. Stem subsidence was seen in 34 of 42 hips (81.0%), and improvement in the initial radiolucency was seen in 15 hips (35.7%) in collarless polished tapered stems at 1 year after operation. In polished stems, stem subsidence in cases with improvement in the initial radiolucency was significantly greater than in those with no change (average 1.12 mm and 0.48 mm, P<0.005). In rough-surface stems partially coated with polymethylmethacrylate (VerSys Cemented Plus), no stem subsidence and no improvement in the initial radiolucency was seen. In polished stems, stem subsidence leads to cement creep and compressive force on the bone-cement interface and can improve the initial radiolucency.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16614823      PMCID: PMC3172779          DOI: 10.1007/s00264-006-0112-0

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  16 in total

1.  Long-term survival of the T-28 versus the TR-28 cemented total hip arthroplasties.

Authors:  J B Meding; J M Nassif; M A Ritter
Journal:  J Arthroplasty       Date:  2000-10       Impact factor: 4.757

2.  The effect of retention of the femoral neck and of cement upon the stability of a proximal femoral prosthesis.

Authors:  P Braud; M A Freeman
Journal:  J Arthroplasty       Date:  1990       Impact factor: 4.757

3.  Surface roughness of debonded straight-tapered stems in cemented THA reduces subsidence but not cement damage.

Authors:  N Verdonschot; R Huiskes
Journal:  Biomaterials       Date:  1998-10       Impact factor: 12.479

4.  Collarless polished tapered stem: clinical and radiological follow-up over 5 years.

Authors:  Piers Yates; Dietmar Gobel; Gordon Bannister
Journal:  J Arthroplasty       Date:  2002-02       Impact factor: 4.757

5.  Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic review.

Authors:  R L Barrack; R D Mulroy; W H Harris
Journal:  J Bone Joint Surg Br       Date:  1992-05

6.  Experience with the Exeter total hip replacement since 1970.

Authors:  J L Fowler; G A Gie; A J Lee; R S Ling
Journal:  Orthop Clin North Am       Date:  1988-07       Impact factor: 2.472

7.  Triple taper polished cemented stem in total hip arthroplasty: rationale for the design, surgical technique, and 7 years of clinical experience.

Authors:  B M Wroblewski; P D Siney; P A Fleming
Journal:  J Arthroplasty       Date:  2001-12       Impact factor: 4.757

8.  Stress relaxation and creep behaviour of normal and carbon fibre reinforced acrylic bone cement.

Authors:  S Pal; S Saha
Journal:  Biomaterials       Date:  1982-04       Impact factor: 12.479

9.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

10.  Comparison of clinical outcomes in total hip arthroplasty using rough and polished cemented stems with essentially the same geometry.

Authors:  Dennis K Collis; Craig G Mohler
Journal:  J Bone Joint Surg Am       Date:  2002-04       Impact factor: 5.284

View more
  2 in total

1.  Stem subsidence of polished and rough double-taper stems: in vitro mechanical effects on the cement-bone interface.

Authors:  Ayumi Kaneuji; Kengo Yamada; Kenichi Hirosaki; Masahiro Takano; Tadami Matsumoto
Journal:  Acta Orthop       Date:  2009-06       Impact factor: 3.717

Review 2.  Temporal subsidence patterns of cemented polished taper-slip stems: a systematic review.

Authors:  Kwaku Baryeh; Jeewaka Mendis; David H Sochart
Journal:  EFORT Open Rev       Date:  2021-05-04
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.