Literature DB >> 15744604

Dynamic creep and mechanical characteristics of SmartSet GHV bone cement.

C Z Liu1, S M Green, N D Watkins, D Baker, A W McCaskie.   

Abstract

The restrained dynamic creep behaviour and mechanical properties of SmartSet GHV bone cement have been investigated at both room temperature and body temperature. It was found that the bone cement behaves significant differently at room temperature from that at body temperature. The test temperature had a strong effect on the creep performance of the bone cements with a higher creep rate observed at body temperature at each loading cycle. For both temperatures, two stages of creep were identified with a higher creep rate during early cycling followed by a steady state creep rate. The relationship between creep deformation and loading cycle can be expressed by a Hyperb 1 model. As a visco-elastic material, the sensitivity of bone cement to the temperature change was evident during mechanical testing. Compared to the mechanical strength at room temperature, a decreased value was demonstrated at body temperature. The bending modulus was very sensitive to the change in testing temperature, where a reduction of 52% was recorded. A significant reduction in compressive and bending strength, 31 and 23% were recorded respectively. The effect of temperature on bending strength was less apparent, where only 13% reduction was exhibited at body temperature compared to room temperature.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15744604     DOI: 10.1007/s10856-005-5893-y

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  21 in total

1.  Effect of mixing method and storage temperature of cement constituents on the fatigue and porosity of acrylic bone cement.

Authors:  G Lewis
Journal:  J Biomed Mater Res       Date:  1999

2.  Characterization of bone cements.

Authors:  J R de Wijn; T J Slooff; F C Driessens
Journal:  Acta Orthop Scand       Date:  1975-04

3.  Will stress shielding limit the longevity of cemented femoral components of total hip replacement?

Authors:  W H Harris
Journal:  Clin Orthop Relat Res       Date:  1992-01       Impact factor: 4.176

4.  Mechanical strength of acrylic bone cements impregnated with antibiotics.

Authors:  E P Lautenschlager; G W Marshall; K E Marks; J Schwartz; C L Nelson
Journal:  J Biomed Mater Res       Date:  1976-11

5.  Comparison of the mechanical properties of Simplex P, Zimmer Regular, and LVC bone cements.

Authors:  J P Davies; D O O'Connor; J A Greer; W H Harris
Journal:  J Biomed Mater Res       Date:  1987-06

6.  Creep characteristics of hand- and vacuum-mixed acrylic bone cement at elevated stress levels.

Authors:  T L Norman; V Kish; J D Blaha; T A Gruen; K Hustosky
Journal:  J Biomed Mater Res       Date:  1995-04

7.  Long-term compressive creep deformation and damage in acrylic bone cements.

Authors:  D J Chwirut
Journal:  J Biomed Mater Res       Date:  1984-01

8.  Characterization of self-curing acrylic bone cements.

Authors:  R P Kusy
Journal:  J Biomed Mater Res       Date:  1978-05

9.  Fracture and fatigue properties of acrylic bone cement: the effects of mixing method, sterilization treatment, and molecular weight.

Authors:  J Graham; L Pruitt; M Ries; N Gundiah
Journal:  J Arthroplasty       Date:  2000-12       Impact factor: 4.757

10.  Effects of cement creep on stem subsidence and stresses in the cement mantle of a total hip replacement.

Authors:  Z Lu; H McKellop
Journal:  J Biomed Mater Res       Date:  1997-02
View more
  2 in total

1.  A prospective randomised radiostereometric analysis trial of SmartSet HV and Palacos R bone cements in primary total hip arthroplasty.

Authors:  Otto S Husby; Kristin Haugan; Pål Benum; Olav A Foss
Journal:  J Orthop Traumatol       Date:  2010-03-03

2.  Gentamicin release from commercially-available gentamicin-loaded PMMA bone cements in a prosthesis-related interfacial gap model and their antibacterial efficacy.

Authors:  Daniëlle Neut; Otto S Kluin; Jonathan Thompson; Henny C van der Mei; Henk J Busscher
Journal:  BMC Musculoskelet Disord       Date:  2010-11-10       Impact factor: 2.362

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.