Literature DB >> 9001149

Multiple tuning of birdcage resonators.

S Amari1, A M Uluğ, J Bornemann, P C van Zijl, P B Barker.   

Abstract

A theoretical framework is presented for designing birdcage resonators for MRI and MR spectroscopy. The analogy between the birdcage problem and the phonon problem in solid-state physics is used to achieve multiple tuning. Allowing that the capacitances in the columns of the cage assume unequal values, it is possible to achieve multiple tuning and simultaneously preserve the sinusoidal current distribution necessary to set a homogeneous magnetic field. Given the physical dimensions of the columns and branches of the cage as well as the desired resonant frequencies, the corresponding values of the capacitances can be calculated exactly. Closed-form expressions for the capacitances are given in terms of the mutual inductances and the desired resonant frequencies. A detailed analysis for a symmetrical low-pass birdcage is presented. The expressions for the resonant frequencies reduce to those given by other authors when only nearest-neighbor mutual inductances are included.

Mesh:

Year:  1997        PMID: 9001149     DOI: 10.1002/mrm.1910370217

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  8 in total

1.  Dual resonant birdcage coils for 1H detected 13C microscopic imaging at 11.7 T.

Authors:  A M Hudson; W Köckenberger; R W Bowtell
Journal:  MAGMA       Date:  2000-06       Impact factor: 2.310

2.  A practical multinuclear transceiver volume coil for in vivo MRI/MRS at 7 T.

Authors:  Chunsheng Wang; Ye Li; Bing Wu; Duan Xu; Sarah J Nelson; Daniel B Vigneron; Xiaoliang Zhang
Journal:  Magn Reson Imaging       Date:  2011-11-03       Impact factor: 2.546

3.  A dual-tuned quadrature volume coil with mixed λ/2 and λ/4 microstrip resonators for multinuclear MRSI at 7 T.

Authors:  Yong Pang; Zhentian Xie; Duan Xu; Douglas A Kelley; Sarah J Nelson; Daniel B Vigneron; Xiaoliang Zhang
Journal:  Magn Reson Imaging       Date:  2011-11-03       Impact factor: 2.546

4.  Common-mode differential-mode (CMDM) method for double-nuclear MR signal excitation and reception at ultrahigh fields.

Authors:  Yong Pang; Xiaoliang Zhang; Zhentian Xie; Chunsheng Wang; Daniel B Vigneron
Journal:  IEEE Trans Med Imaging       Date:  2011-06-20       Impact factor: 10.048

Review 5.  High-performance radiofrequency coils for (23)Na MRI: brain and musculoskeletal applications.

Authors:  Graham C Wiggins; Ryan Brown; Karthik Lakshmanan
Journal:  NMR Biomed       Date:  2015-09-24       Impact factor: 4.044

6.  Optimization and comparison of two practical dual-tuned birdcage configurations for quantitative assessment of articular cartilage with sodium magnetic resonance imaging.

Authors:  Gunthard Lykowsky; Flavio Carinci; Markus Düring; Daniel Weber; Peter M Jakob; Daniel Haddad
Journal:  Quant Imaging Med Surg       Date:  2015-12

7.  A flexible nested sodium and proton coil array with wideband matching for knee cartilage MRI at 3T.

Authors:  Ryan Brown; Karthik Lakshmanan; Guillaume Madelin; Leeor Alon; Gregory Chang; Daniel K Sodickson; Ravinder R Regatte; Graham C Wiggins
Journal:  Magn Reson Med       Date:  2015-10-26       Impact factor: 4.668

8.  Design and test of a double-nuclear RF coil for (1)H MRI and (13)C MRSI at 7T.

Authors:  Omar Rutledge; Tiffany Kwak; Peng Cao; Xiaoliang Zhang
Journal:  J Magn Reson       Date:  2016-04-07       Impact factor: 2.229

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.