Literature DB >> 8925585

Paired comparison of vascular wall reactions to Palmaz stents, Strecker tantalum stents, and Wallstents in canine iliac and femoral arteries.

K H Barth1, R Virmani, J Froelich, T Takeda, S V Lossef, J Newsome, R Jones, D Lindisch.   

Abstract

BACKGROUND: Palmaz stents, Strecker stents, and Wallstents, all used clinically, differ substantially in their physical characteristics, yet how differently the vascular wall reacts to them has not been demonstrated conclusively. We therefore undertook a side-by-side comparison. METHODS AND
RESULTS: One stent was implanted into each canine external iliac and/or the flexing portion of the proximal femoral artery. In 9 dogs, Palmaz stents were placed vis-à-vis Strecker stents, with follow-up of 2 and 4 months. In 7 dogs, Palmaz stents were placed vis-à-vis Wallstents, with 4 months of follow-up. Angiographic midstent luminal diameters immediately after placement and at follow-up as well as midstent cross-sectional areas of neointima were compared for significant differences. In addition, neointimal maturation, medial atrophy, and stent-related trauma were assessed. Angiographically, all arteries remained open. The degree of luminal narrowing by recoil and neointima never reached 50% and was modest for Palmaz stents and Wallstents (P = .33) but significantly higher for Strecker stents (P < .0001 compared with Palmaz stents). This corresponded histologically to a significantly thicker neointima (P = .003) over Strecker than over Palmaz stents but not between Palmaz stents and Wallstents (P = .18). Neointimal buildup was generally more pronounced in the femoral artery segments than in the iliac segments. Maturation of the neointima over Palmaz stents was much further advanced than over Strecker stents and slightly more advanced than over Wallstents. Pressure-related atrophy of the tunica media was least for Strecker stents and more pronounced but similar for Wallstents and Palmaz stents. Wallstent wire ends caused some wall trauma; several femoral Palmaz stent struts protruded through the media.
CONCLUSIONS: The lower-hoop-strength, higher-profile tantalum Strecker stent is affected by vascular wall recoil and evokes a greater degree of neointima formation than the lower-profile, higher-hoop-strength Palmaz stent and Wallstent. Medial atrophy is pronounced outside the latter two stents. The rigid Palmaz stent can penetrate through the vascular wall in flexing arteries.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8925585     DOI: 10.1161/01.cir.93.12.2161

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  10 in total

1.  Three-dimensional analysis of in vivo coronary stent--coronary artery interactions.

Authors:  Robert Liao; Nathan E Green; S Y James Chen; John C Messenger; Adam R Hansgen; Bertron M Groves; John D Carroll
Journal:  Int J Cardiovasc Imaging       Date:  2004-08       Impact factor: 2.357

Review 2.  Cutting balloons for the treatment of vascular stenoses.

Authors:  Dimitrios Tsetis; Robert Morgan; Anna-Maria Belli
Journal:  Eur Radiol       Date:  2006-04-12       Impact factor: 5.315

3.  Minimally invasive vascular techniques.

Authors:  M R Lepore; M Yoselevitz; W C Sternbergh; S R Money
Journal:  Ochsner J       Date:  2000-07

4.  Recanalization results after carotid stent placement.

Authors:  Joachim Berkefeld; Bernd Turowski; Andreas Dietz; Heinrich Lanfermann; Matthias Sitzer; Thomas Schmitz-Rixen; Helmuth Steinmetz; Friedhelm E Zanella
Journal:  AJNR Am J Neuroradiol       Date:  2002-01       Impact factor: 3.825

5.  Systematical evolution on a Zn-Mg alloy potentially developed for biodegradable cardiovascular stents.

Authors:  Song Lin; Xiaolin Ran; Xinhao Yan; Qilong Wang; Jack G Zhou; Tingzhang Hu; Guixue Wang
Journal:  J Mater Sci Mater Med       Date:  2019-11-01       Impact factor: 3.896

6.  Efficacy of treatment of severe carotid bifurcation stenosis by using self-expanding stents without deliberate use of angioplasty balloons.

Authors:  Stephen P Lownie; David M Pelz; Donald H Lee; Suleyman Men; Irene Gulka; Paul Kalapos
Journal:  AJNR Am J Neuroradiol       Date:  2005-05       Impact factor: 3.825

7.  Carotid artery stenting without post-stenting balloon dilatation.

Authors:  Atsushi Ogata; Makoto Sonobe; Noriyuki Kato; Tomosato Yamazaki; Hiromichi Kasuya; Go Ikeda; Shunichiro Miki; Toshio Matsushima
Journal:  J Neurointerv Surg       Date:  2013-09-07       Impact factor: 5.836

8.  Mid-Term Outcomes of Stent Overlap in Long Total Occluded Lesions of Superficial Femoral Artery.

Authors:  Ulas Bildirici; Mujdat Aktas; Emir Dervis; Umut Celikyurt
Journal:  Med Sci Monit       Date:  2017-06-26

9.  A promising biodegradable magnesium alloy suitable for clinical vascular stent application.

Authors:  Lin Mao; Li Shen; Jiahui Chen; Xiaobo Zhang; Minsuk Kwak; Yu Wu; Rong Fan; Lei Zhang; Jia Pei; Guangyin Yuan; Chengli Song; Junbo Ge; Wenjiang Ding
Journal:  Sci Rep       Date:  2017-04-11       Impact factor: 4.379

10.  Swine model of in-stent stenosis in the iliac artery evaluating the serial time course.

Authors:  Osamu Ishikawa; Minoru Tanaka; Kenjiro Konno; Terumitsu Hasebe; Ayumi Horikawa; Akira Iijima; Nobuhito Saito; Koki Takahashi
Journal:  Exp Anim       Date:  2018-08-01
  10 in total