Literature DB >> 15529914

Three-dimensional analysis of in vivo coronary stent--coronary artery interactions.

Robert Liao1, Nathan E Green, S Y James Chen, John C Messenger, Adam R Hansgen, Bertron M Groves, John D Carroll.   

Abstract

Stent implantation results in important three-dimensional (3D) changes in arterial geometry which may be associated with adverse events. Previous attempts to quantify these 3D changes have been limited by two-dimensional techniques. Using a 3D reconstruction technique, vessel curvatures at end-diastole (ED) and end-systole (ES) were measured before and after stent placement of 100 stents (3 stent cell designs, 6 stent types). After stenting, the mean curvature at ED and ES decreased by 22 and 21%, respectively, and represents a straightening effect on the treated vessel. This effect was proportional to the amount of baseline curvature as high vessel curvature predicted more profound vessel straightening. When analyzed by stent cell design, closed-cell stents resulted in more vessel straightening than other designs (open cell or modified slotted tubes). Stent implantation resulted in the transmission of shape changes to stent ends and generated hinge points or buckling. Stent implantation creates 3D changes in arterial geometry which can be quantified using a 3D reconstruction technique.

Mesh:

Year:  2004        PMID: 15529914     DOI: 10.1023/b:caim.0000041950.84736.e6

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  24 in total

1.  Longitudinal straightening effect of stents is an additional predictor for major adverse cardiac events. Austrian Wiktor Stent Study Group and European Paragon Stent Investigators.

Authors:  M Gyöngyösi; P Yang; A Khorsand; D Glogar
Journal:  J Am Coll Cardiol       Date:  2000-05       Impact factor: 24.094

2.  Coronary stent implantation changes 3-D vessel geometry and 3-D shear stress distribution.

Authors:  J J Wentzel; D M Whelan; W J van der Giessen; H M van Beusekom; I Andhyiswara; P W Serruys; C J Slager; R Krams
Journal:  J Biomech       Date:  2000-10       Impact factor: 2.712

3.  Influence of stent design on 1-year outcome after coronary stent placement: a randomized comparison of five stent types in 1,147 unselected patients.

Authors:  A Kastrati; J Dirschinger; P Boekstegers; S Elezi; H Schühlen; J Pache; G Steinbeck; C Schmitt; K Ulm; F J Neumann; A Schömig
Journal:  Catheter Cardiovasc Interv       Date:  2000-07       Impact factor: 2.692

4.  Increased risk of restenosis after placement of gold-coated stents: results of a randomized trial comparing gold-coated with uncoated steel stents in patients with coronary artery disease.

Authors:  A Kastrati; A Schömig; J Dirschinger; J Mehilli; N von Welser; J Pache; H Schühlen; T Schilling; C Schmitt; F J Neumann
Journal:  Circulation       Date:  2000-05-30       Impact factor: 29.690

5.  Assessment of the trackability, flexibility, and conformability of coronary stents: a comparative analysis.

Authors:  Régis Rieu; Paul Barragan; Vincent Garitey; Pierre O Roquebert; Jean Fuseri; Philippe Commeau; Joel Sainsous
Journal:  Catheter Cardiovasc Interv       Date:  2003-08       Impact factor: 2.692

6.  Hemodynamic shear stress and its role in atherosclerosis.

Authors:  A M Malek; S L Alper; S Izumo
Journal:  JAMA       Date:  1999-12-01       Impact factor: 56.272

7.  Improved determination of biplane imaging geometry from two projection images and its application to three-dimensional reconstruction of coronary arterial trees.

Authors:  S Y Chen; C E Metz
Journal:  Med Phys       Date:  1997-05       Impact factor: 4.071

8.  Angiographic and clinical predictors of acute closure after native vessel coronary angioplasty.

Authors:  S G Ellis; G S Roubin; S B King; J S Douglas; W S Weintraub; R G Thomas; W R Cox
Journal:  Circulation       Date:  1988-02       Impact factor: 29.690

9.  3D coronary reconstruction from routine single-plane coronary angiograms: clinical validation and quantitative analysis of the right coronary artery in 100 patients.

Authors:  J C Messenger; S Y Chen; J D Carroll; J E Burchenal; K Kioussopoulos; B M Groves
Journal:  Int J Card Imaging       Date:  2000-12

10.  Assessment of diffuse coronary artery disease by quantitative analysis of coronary morphology based upon 3-D reconstruction from biplane angiograms.

Authors:  A Wahle; E Wellnhofer; I Mugaragu; H U Saner; H Oswald; E Fleck
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

View more
  8 in total

Review 1.  Update on Provisional Technique for Bifurcation Interventions.

Authors:  Lazzaro Paraggio; Francesco Burzotta; Cristina Aurigemma; Carlo Trani
Journal:  Curr Cardiol Rep       Date:  2016-03       Impact factor: 2.931

2.  Three-dimensional imaging for the guidance of coronary interventional procedures: impact on clinical decision making?

Authors:  Paul Schoenhagen
Journal:  Int J Cardiovasc Imaging       Date:  2004-12       Impact factor: 2.357

3.  The effect of intracranial stent implantation on the curvature of the cerebrovasculature.

Authors:  R M King; J-Y Chueh; I M J van der Bom; C F Silva; S L Carniato; G Spilberg; A K Wakhloo; M J Gounis
Journal:  AJNR Am J Neuroradiol       Date:  2012-04-26       Impact factor: 3.825

4.  Stent fracture at the proximal shaft of the left main stem.

Authors:  Jae Ho Lee; Suk Min Seo; Eun Oh Kim; Hyo Jun Ahn; Yang Won Lee; Yul-Hee Cho; Inwoon Baek; You Suk Oh; Jihyun Yu; Ki-Bae Seung
Journal:  Korean Circ J       Date:  2011-12-31       Impact factor: 3.243

5.  Clinical characteristics of coronary drug-eluting stent fracture: insights from a two-center des registry.

Authors:  Kyung Woo Park; Jin Joo Park; In-Ho Chae; Jae-Bin Seo; Han-Mo Yang; Hae-Young Lee; Hyun-Jae Kang; Young-Seok Cho; Tae-Jin Yeon; Woo-Young Chung; Bon-Kwon Koo; Dong-Ju Choi; Byung-Hee Oh; Young-Bae Park; Hyo-Soo Kim
Journal:  J Korean Med Sci       Date:  2010-12-22       Impact factor: 2.153

6.  Tissue-engineered blood vessel mimics in complex geometries for intravascular device testing.

Authors:  Robert Dalton Chavez; Sara Leifer Walls; Kristen O'Halloran Cardinal
Journal:  PLoS One       Date:  2019-06-26       Impact factor: 3.240

7.  Three-dimensional evaluation of the spatial morphology of stented coronary artery segments in relation to restenosis.

Authors:  Áron Üveges; Csaba Jenei; Tibor Kiss; Zoltán Szegedi; Balázs Tar; Gábor Tamás Szabó; Dániel Czuriga; Zsolt Kőszegi
Journal:  Int J Cardiovasc Imaging       Date:  2019-05-24       Impact factor: 2.357

8.  Effect of Stent Radial Force on Stress Pattern After Deployment: A Finite Element Study.

Authors:  Alessandro Borghi; Olive Murphy; Reza Bahmanyar; Chris McLeod
Journal:  J Mater Eng Perform       Date:  2014-02-26       Impact factor: 1.819

  8 in total