Literature DB >> 31677119

Systematical evolution on a Zn-Mg alloy potentially developed for biodegradable cardiovascular stents.

Song Lin1, Xiaolin Ran1, Xinhao Yan2, Qilong Wang1, Jack G Zhou2, Tingzhang Hu3, Guixue Wang4.   

Abstract

To reduce the long-term side effects of permanent metallic stents, a new generation of cardiovascular stents called "biodegradable stents" is being extensively developed. Zinc has been considered as a promising candidate material for biodegradable cardiovascular stents due to its excellent biocompatibility and appropriate biodegradability. However, weak mechanical properties limit its further clinic application. In this study, hot extruded pure Zn and Zn-0.02 Mg alloy were prepared. Compared with pure Zn, Zn-0.02 Mg alloy showed more homogeneous microstructure, much smaller grain size and higher mechanical strength. Zn-0.02 Mg alloy presented uniform corrosion morphologies during the immersion process, and its corrosion rates was higher than that of pure Zn. Hemocompatibility results showed that the Zn-based alloy had extremely low hemolysis rate (0.74 ± 0.15%) and strong inhibitory effect on blood coagulation, platelet adhesion and aggregation. Zn-0.02 Mg alloy also exhibited excellent cytocompatibility. Its extracts could significantly promote the proliferation of endothelial cells. Moreover, the antibacterial activities of the Zn-based alloy were demonstrated by spread plate assay, live/dead viability assay and bacterial morphology observation. These results indicate that the extruded Zn-0.02 Mg alloy has a potential in biodegradable cardiovascular stents.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31677119     DOI: 10.1007/s10856-019-6324-9

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  38 in total

1.  Usefulness of a cobalt chromium coronary stent alloy.

Authors:  Dean J Kereiakes; David A Cox; James B Hermiller; Mark G Midei; William B Bachinsky; E Dean Nukta; Martin B Leon; Stanley Fink; Linda Marin; Alexandra J Lansky
Journal:  Am J Cardiol       Date:  2003-08-15       Impact factor: 2.778

2.  The incidence and clinical impact of stent strut fractures developed after drug-eluting stent implantation.

Authors:  Wook-Sung Chung; Chul-Soo Park; Ki-Bae Seung; Pum-Joon Kim; Jong-Min Lee; Bon-Kwon Koo; Yang-Soo Jang; Joo-Young Yang; Jung-Han Yoon; Doo-Il Kim; Young-Won Yoon; Jong-Seon Park; Yoon-Haeng Cho; Seung-Jung Park
Journal:  Int J Cardiol       Date:  2007-04-16       Impact factor: 4.164

3.  Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation.

Authors:  Stéphane Cook; Peter Wenaweser; Mario Togni; Michael Billinger; Cyrill Morger; Christian Seiler; Rolf Vogel; Otto Hess; Bernhard Meier; Stephan Windecker
Journal:  Circulation       Date:  2007-05-08       Impact factor: 29.690

4.  A simplified in vivo approach for evaluating the bioabsorbable behavior of candidate stent materials.

Authors:  Daniel Pierson; Jacob Edick; Aaron Tauscher; Ellen Pokorney; Patrick Bowen; Jesse Gelbaugh; Jon Stinson; Heather Getty; Chee Huei Lee; Jaroslaw Drelich; Jeremy Goldman
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2011-09-08       Impact factor: 3.368

5.  Temporal Trends in Adverse Events After Everolimus-Eluting Bioresorbable Vascular Scaffold Versus Everolimus-Eluting Metallic Stent Implantation: A Meta-Analysis of Randomized Controlled Trials.

Authors:  Rocco A Montone; Giampaolo Niccoli; Federico De Marco; Silvia Minelli; Fabrizio D'Ascenzo; Luca Testa; Francesco Bedogni; Filippo Crea
Journal:  Circulation       Date:  2017-05-30       Impact factor: 29.690

Review 6.  Zinc in human health: effect of zinc on immune cells.

Authors:  Ananda S Prasad
Journal:  Mol Med       Date:  2008 May-Jun       Impact factor: 6.354

7.  Evolution of the degradation mechanism of pure zinc stent in the one-year study of rabbit abdominal aorta model.

Authors:  Hongtao Yang; Cong Wang; Chaoqiang Liu; Houwen Chen; Yifan Wu; Jintao Han; Zichang Jia; Wenjiao Lin; Deyuan Zhang; Wenting Li; Wei Yuan; Hui Guo; Huafang Li; Guangxin Yang; Deling Kong; Donghui Zhu; Kazuki Takashima; Liqun Ruan; Jianfeng Nie; Xuan Li; Yufeng Zheng
Journal:  Biomaterials       Date:  2017-08-16       Impact factor: 12.479

8.  Effectiveness of Biodegradable Magnesium Alloy Stents in Coronary Artery and Femoral Artery.

Authors:  Yunan Yue; Lili Wang; Nuo Yang; Jinglin Huang; Licheng Lei; Huiming Ye; Lihui Ren; Shuixiang Yang
Journal:  J Interv Cardiol       Date:  2015-08       Impact factor: 2.279

9.  Combined effect of xylitol, NaF and ZnCl2 on growth and metabolism of Streptococcus sobrinus OMZ 176.

Authors:  A A Scheie; S Assev; G Rölla
Journal:  APMIS       Date:  1988-09       Impact factor: 3.205

10.  In vitro corrosion and biocompatibility of binary magnesium alloys.

Authors:  Xuenan Gu; Yufeng Zheng; Yan Cheng; Shengping Zhong; Tingfei Xi
Journal:  Biomaterials       Date:  2008-11-09       Impact factor: 12.479

View more
  3 in total

1.  Influence of bovine serum albumin on corrosion behaviour of pure Zn in phosphate buffered saline.

Authors:  Lijun Liu; Lili Lu; Hai-Jun Zhang; Lu-Ning Wang
Journal:  J Mater Sci Mater Med       Date:  2021-08-18       Impact factor: 3.896

2.  Zinc alloy-based bone internal fixation screw with antibacterial and anti-osteolytic properties.

Authors:  Xinhua Qu; Hongtao Yang; Bo Jia; Minqi Wang; Bing Yue; Yufeng Zheng; Kerong Dai
Journal:  Bioact Mater       Date:  2021-05-18

Review 3.  Recent Advances in Research on Antibacterial Metals and Alloys as Implant Materials.

Authors:  Juyang Jiao; Shutao Zhang; Xinhua Qu; Bing Yue
Journal:  Front Cell Infect Microbiol       Date:  2021-07-02       Impact factor: 5.293

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.