Literature DB >> 8861581

Advantage of the transprosthetic drainage system (TDS) for application in cemented hip arthroplasty--a standardized experimental comparison with other cementing techniques.

J Schmidt1, R Specht, G Steur.   

Abstract

We constructed a computer-assisted implantation device to compare different cementing techniques of stem implantation in total hip arthroplasty, thus avoiding any manual influence during implantation. We used an intramedullary plug in each case. Conventional cementing techniques, employing an additional lateral drain for the femoral canal or applying the cement by hand, did not lead to a satisfyingly reproducible quality of the cement mantle. With the vacuum cementing technique, in which an additional cannulated screw is inserted into the plug from the lateral side of the femur for the application of the vacuum, the cement mantle improved in quality, but there was still a relatively high number of bubbles incorporated in the cement. We think that, even under improved experimental circumstances, it is not always possible to place the cannulated screw correctly into the plug in order to achieve a satisfying drainage of the femoral canal with this procedure. The transprosthetic drainage system showed the best results due to the optimized position and working capacity of the drain.

Entities:  

Mesh:

Year:  1996        PMID: 8861581     DOI: 10.1007/bf00434544

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  9 in total

1.  Anchorage of the femoral head prosthesis to the shaft of the femur.

Authors:  J CHARNLEY
Journal:  J Bone Joint Surg Br       Date:  1960-02

2.  Improved cementation in total hip replacement.

Authors:  K Søballe; F Christensen
Journal:  Arch Orthop Trauma Surg       Date:  1988

Review 3.  Modern cementing techniques. An experimental study of vacuum insertion of bone cement.

Authors:  K Draenert
Journal:  Acta Orthop Belg       Date:  1989       Impact factor: 0.500

4.  Improved fixation of the femoral component after total hip replacement using a methacrylate intramedullary plug.

Authors:  I Oh; C E Carlson; W W Tomford; W H Harris
Journal:  J Bone Joint Surg Am       Date:  1978-07       Impact factor: 5.284

5.  Some clinically relevant variables affecting the mechanical behaviour of bone cement.

Authors:  A J Lee; R S Ling; S S Vangala
Journal:  Arch Orthop Trauma Surg       Date:  1978-08-11

6.  The effect of thickness and pressure on the curing of PMMA bone cement for the total hip joint replacement.

Authors:  G C Sih; G M Connelly; A T Berman
Journal:  J Biomech       Date:  1980       Impact factor: 2.712

7.  [Detection and effects of bone marrow intravasations in operations in the area of the femoral marrow cavity].

Authors:  K Wenda; G Ritter; J Ahlers; W D von Issendorff
Journal:  Unfallchirurg       Date:  1990-02       Impact factor: 1.000

8.  Loosening of the femoral component after use of the medullary-plug cementing technique. Follow-up note with a minimum five-year follow-up.

Authors:  W H Harris; W A McGann
Journal:  J Bone Joint Surg Am       Date:  1986-09       Impact factor: 5.284

9.  Intraoperative transesophageal two-dimensional echocardiography in total hip replacement.

Authors:  C Ulrich; C Burri; O Wörsdörfer; H Heinrich
Journal:  Arch Orthop Trauma Surg       Date:  1986
  9 in total
  1 in total

Review 1.  [Reportable incidents with surgical instruments in orthopedic surgery].

Authors:  D Kluess; K Zenk; W Mittelmeier
Journal:  Orthopade       Date:  2014-06       Impact factor: 1.087

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.