Literature DB >> 3778162

Intraoperative transesophageal two-dimensional echocardiography in total hip replacement.

C Ulrich, C Burri, O Wörsdörfer, H Heinrich.   

Abstract

A number of studies in medical literature suggest that during implantation of hip prostheses pulmonary embolism of medullary contents and of air may occur. Proof of this suggestion was based on histological examination of lung tissue in animal experiments as well as on post mortem examinations of human tissue. In vivo evidence of this suspected embolism has been lacking so far, since an appropriate technique has not been available. Using transesophageal two-dimensional echocardiography, continuous imaging of the right atrium and the right ventricle can be performed in order to prove this suspected embolization in vivo. Thus, in a prospective randomized study of 26 patients undergoing hip surgery, the right atrium and right ventricle were continuously imaged. Simultaneously, the end-expiratory CO2 partial pressure was recorded. The medical literature suggests that a venting hole in the shaft of the femur prevents the rise in pressure in the medullary space and thus also averts embolism. Therefore, prior to the implantation of the shaft prosthesis, and in order to vent the medullary space, in 13 patients a 4.5-mm lateral borehole was drilled into the femoral shaft, located two finger breadths distal to the point were the end of the prosthesis would be positioned. In 12 of 13 patients in the control group without boreholes, transesophageal two-dimensional echocardiography revealed that air bubbles formed during the implantation of the shaft. In the group with boreholes, however, presence of air could be demonstrated in only four patients (P less than 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1986        PMID: 3778162     DOI: 10.1007/bf00449925

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0344-8444


  18 in total

1.  Arterial hypotension and hypoxaemia during total hip replacement: the importance of thromboplastic products, fat embolism and acrylic monomers.

Authors:  J Modig; C Busch; S Olerud; T Saldeen; G Waernbaum
Journal:  Acta Anaesthesiol Scand       Date:  1975       Impact factor: 2.105

2.  Experimental production of vascular hypotension, and bone marrow and fat embolism with methylmethacrylate cement. Traumatic hypertension of bone.

Authors:  A L Breed
Journal:  Clin Orthop Relat Res       Date:  1974 Jul-Aug       Impact factor: 4.176

3.  Intramedullary pressure and pulmonary embolism of femoral medullary contents in dogs during insertion of bone cement and a prosthesis.

Authors:  T Kallos; J E Enis; F Gollan; J H Davis
Journal:  J Bone Joint Surg Am       Date:  1974-10       Impact factor: 5.284

4.  Elevation of intramedullary pressure when methylmethacrylate is inserted in total hip arthroplasty.

Authors:  R G Tronzo; T Kallos; M Q Wyche
Journal:  J Bone Joint Surg Am       Date:  1974-06       Impact factor: 5.284

5.  Cardiovascular responses after methylmethacrylic cement.

Authors:  D Cadle; M L James; R S Ling; R F Piper; D L Pryer; C C Wilmshurst
Journal:  Br Med J       Date:  1972-10-14

6.  Cardiac arrest associated with bone cement.

Authors:  J N Powell; P J McGrath; S K Lahiri; P Hill
Journal:  Br Med J       Date:  1970-08-08

7.  [Clinical use of transesophageal echocardiography].

Authors:  M Schlüter; W Thier; A Hinrichs; P Kremer; V Siglow; P Hanrath
Journal:  Dtsch Med Wochenschr       Date:  1984-05-04       Impact factor: 0.628

8.  New clinico-pathophysiological studies on the bone cement implantation syndrome.

Authors:  H Rinecker
Journal:  Arch Orthop Trauma Surg       Date:  1980

9.  [Does methylmethacrylate induce cardiovascular complications during alloarthroplastic surgery of the hip joint? (AUTHOR'S TRANSL)].

Authors:  G Schlag; H J Schliep; E Dingeldein; A Grieben; W Ringsdorf
Journal:  Anaesthesist       Date:  1976-02       Impact factor: 1.041

10.  [Transesophageal 2-dimensional echocardiography in hip endoprostheses].

Authors:  H Heinrich; P Kremer; H Winter; O Wörsdorfer; F W Ahnefeld
Journal:  Anaesthesist       Date:  1985-03       Impact factor: 1.041

View more
  7 in total

1.  Advantage of the transprosthetic drainage system (TDS) for application in cemented hip arthroplasty--a standardized experimental comparison with other cementing techniques.

Authors:  J Schmidt; R Specht; G Steur
Journal:  Arch Orthop Trauma Surg       Date:  1996       Impact factor: 3.067

2.  Bone cement implantation syndrome. A prospective randomised trial for use of antihistamine blockade.

Authors:  W R Lamadé; W Friedl; B Schmid; P J Meeder
Journal:  Arch Orthop Trauma Surg       Date:  1995       Impact factor: 3.067

3.  Pathogenesis and prophylaxis of circulatory reactions during total hip replacement.

Authors:  K Wenda; J Degreif; M Runkel; G Ritter
Journal:  Arch Orthop Trauma Surg       Date:  1993       Impact factor: 3.067

4.  [Detection of bone marrow embolism in femoral intramedullary nailing using transesophageal echocardiography].

Authors:  K Wenda; K J Henrichs; M Biegler; R Erbel
Journal:  Unfallchirurgie       Date:  1989-04

5.  [Clinical relevance of fat embolism. Review of the literature].

Authors:  C Hirschnitz; P E Ochsner
Journal:  Unfallchirurgie       Date:  1996-04

6.  Consequences and prevention of inadvertent internal fixation of primary osseous sarcomas.

Authors:  Sheila Conway Adams; Benjamin K Potter; Zakariah Mahmood; J David Pitcher; H Thomas Temple
Journal:  Clin Orthop Relat Res       Date:  2008-10-21       Impact factor: 4.176

7.  Embolism detected by transoesophageal echocardiography during hip arthroplasty.

Authors:  N D Lafont; W M Kostucki; P H Marchand; M N Michaux; J G Boogaerts
Journal:  Can J Anaesth       Date:  1994-09       Impact factor: 5.063

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.