Abstract

Insufficient cementation has been suggested to be the most common cause of loosening of the femoral component after total hip arthroplasty. A clinical and radiographic study of 129 consecutive, primary total hip replacements was performed 5 years after surgery, in order to evaluate the significance of femoral plugging, special attention being focused on cementation and radiographic loosening. A polyethylene medullary plug was used in 78 hips which were compared with 51 non-plugged hips with respect to the clinical course and radiographic appearance. The cement mantle around the femoral component was thicker, and the packing of cement significantly improved when the plug was used. The frequency of radiographic loosening was smaller in the plugged group but with no statistical significance. There was no difference in clinical results between the compared groups. Our results indicate that medullary plugging improves the cementation and in particular prevents insufficient cementation of the femoral component.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3345136     DOI: 10.1007/bf00463525

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0344-8444


  19 in total

1.  Improvements in total hip prosthesis implantation technique. A cement-proof seal for the lower medullary cavity and a dihedral self-stabilizing trochanteric osteotomy.

Authors:  B G Weber; G Stühmer
Journal:  Arch Orthop Trauma Surg       Date:  1979-03-19

2.  The long-term results of low-friction arthroplasty of the hip performed as a primary intervention.

Authors:  J Charnley
Journal:  J Bone Joint Surg Br       Date:  1972-02

3.  Factors leading to rearthroplasty in a material with radiographically loose total hip prostheses.

Authors:  C Hierton; G Blomgren; U Lindgren
Journal:  Acta Orthop Scand       Date:  1983-08

4.  Improved fixation of the femoral component after total hip replacement using a methacrylate intramedullary plug.

Authors:  I Oh; C E Carlson; W W Tomford; W H Harris
Journal:  J Bone Joint Surg Am       Date:  1978-07       Impact factor: 5.284

5.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

6.  Changes in the calcar femoris in relation to cement technology in total hip replacement.

Authors:  F Bocco; P Langan; J Charnley
Journal:  Clin Orthop Relat Res       Date:  1977-10       Impact factor: 4.176

7.  Complications of total hip arthroplasty treated by reoperation.

Authors:  D R Nolan; R H Fitzgerald; R D Beckenbaugh; M B Coventry
Journal:  J Bone Joint Surg Am       Date:  1975-10       Impact factor: 5.284

8.  Total hip arthroplasties in patients less than forty-five years old.

Authors:  L D Dorr; G K Takei; J P Conaty
Journal:  J Bone Joint Surg Am       Date:  1983-04       Impact factor: 5.284

9.  Results of revision for mechanical failure after cemented total hip replacement, 1979 to 1982. A two to five-year follow-up.

Authors:  J J Callaghan; E A Salvati; P M Pellicci; P D Wilson; C S Ranawat
Journal:  J Bone Joint Surg Am       Date:  1985-09       Impact factor: 5.284

10.  Revision total hip arthroplasty.

Authors:  P M Pellicci; P D Wilson; C B Sledge; E A Salvati; C S Ranawat; R Poss
Journal:  Clin Orthop Relat Res       Date:  1982-10       Impact factor: 4.176

View more
  2 in total

1.  Advantage of the transprosthetic drainage system (TDS) for application in cemented hip arthroplasty--a standardized experimental comparison with other cementing techniques.

Authors:  J Schmidt; R Specht; G Steur
Journal:  Arch Orthop Trauma Surg       Date:  1996       Impact factor: 3.067

2.  Comparison between straight- and curved-stem Müller femoral prostheses. 5- to 10-year results of 545 total hip replacements.

Authors:  J Wilson-MacDonald; E Morscher
Journal:  Arch Orthop Trauma Surg       Date:  1990       Impact factor: 3.067

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.