Literature DB >> 3745245

Loosening of the femoral component after use of the medullary-plug cementing technique. Follow-up note with a minimum five-year follow-up.

W H Harris, W A McGann.   

Abstract

Of the 171 total hip replacements reported on previously that had had a minimum length of follow-up of two years, 117 replacements in 104 patients were analyzed at a minimum of five years postoperatively (average, seventy-four months; range, sixty to ninety-four months) to assess the rate of loosening of the femoral component. At the time of cementing of the femoral component, the medullary canal had been plugged with a bolus of bone cement and then filled with doughy Simplex-P methylmethacrylate in a retrograde fashion using a cement gun. The femoral components, made of a chromium-cobalt alloy, had a rectangular cross-sectional shape to the stem and a medial collar. Three categories of loosening were used: definite (requiring radiographic evidence of migration of the component or the cement), probable (requiring evidence of a complete radiolucent zone at the bone-cement interface on one radiograph or more), and possible (a radiolucent zone at the cement-bone interface of more than 49 per cent but less than 100 per cent on one radiograph or more). One femoral component had been removed for aseptic loosening at another hospital, leaving the patient with a resection arthroplasty. One other (1.7 per cent) was definitely loose. No femoral component was categorized as probably loose, and only two were possibly loose.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3745245

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  36 in total

1.  Orthopedic prosthesis fixation.

Authors:  J B Park
Journal:  Ann Biomed Eng       Date:  1992       Impact factor: 3.934

2.  Isolated acetabular revision after total hip arthroplasty: results at 5-9 years of follow-up.

Authors:  Xiao-Dong Chen; James P Waddell; Jane Morton; Emil H Schemitsch
Journal:  Int Orthop       Date:  2005-08-11       Impact factor: 3.075

3.  Failed hip replacements.

Authors:  R N Villar
Journal:  BMJ       Date:  1992-01-04

4.  Minimum 10-year survival of Kerboull cemented stems according to surface finish.

Authors:  Moussa Hamadouche; François Baqué; Nicolas Lefevre; Marcel Kerboull
Journal:  Clin Orthop Relat Res       Date:  2008-01-10       Impact factor: 4.176

5.  Expansion of CD14+CD16+ peripheral monocytes among patients with aseptic loosening.

Authors:  W Wu; X Zhang; C Zhang; T Tang; W Ren; K Dai
Journal:  Inflamm Res       Date:  2009-03-17       Impact factor: 4.575

6.  Total hip arthroplasty for developmental hip dysplasia.

Authors:  G Papachristou; P Hatzigrigoris; K Panousis; S Plessas; J Sourlas; C Levidiotis; E Chronopoulos
Journal:  Int Orthop       Date:  2005-12-14       Impact factor: 3.075

Review 7.  [Cementing techniques for hip resurfacing arthroplasty. What do we know?].

Authors:  R G Bitsch; T P Schmalzried
Journal:  Orthopade       Date:  2008-07       Impact factor: 1.087

8.  Femoral component fixation with and without intramedullary plug. A 6-year follow-up.

Authors:  S Suominen; I Antti-Poika; K Tallroth; S Santavirta; P Voutilainen; T S Lindholm
Journal:  Arch Orthop Trauma Surg       Date:  1996       Impact factor: 3.067

9.  Therapy with pulsed electromagnetic fields in aseptic loosening of total hip protheses: a prospective study.

Authors:  K Konrad; K Sevcic; K Földes; E Piroska; E Molnár
Journal:  Clin Rheumatol       Date:  1996-07       Impact factor: 2.980

10.  Proximal femoral reconstructions with bone impaction grafting and metal mesh.

Authors:  Martín A Buttaro; Fernando Comba; Francisco Piccaluga
Journal:  Clin Orthop Relat Res       Date:  2009-03-18       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.