Literature DB >> 8857435

Transgastric, pulsed Doppler echocardiographic determination of cardiac output.

A Descorps-Declere1, N Smail, B Vigue, J Duranteau, O Mimoz, A Edouard, K Samii.   

Abstract

OBJECTIVE: The aim of this study was to evaluate the accuracy of cardiac output measurement with transesophageal echocardiography (TEE) using a transgastric, pulsed Doppler method in acutely ill patients.
DESIGN: Cardiac output was simultaneously measured by thermodilution (TD) and a transgastric, pulsed Doppler method.
SETTING: The study was carried out in a surgical intensive care unit as part of the management protocol of the patients. PATIENTS: Thirty consecutive acutely ill patients with a Swan-Ganz catheter, mechanically ventilated, sedated and with a stable hemodynamic condition were included. MEASUREMENTS: Pulsed Doppler TEE was performed using a transgastric approach in order to obtain a long axis view of the left ventricle. Cardiac output was calculated from the left ventricular outflow tract diameter, the velocity time integral of the blood flow profile and heart rate.
RESULTS: One patient was excluded because of the presence of aortic regurgitation and another, because of the impossibility of obtaining a transgastric view. Twenty-eight simultaneous measurements were performed in 28 patients. A clinically acceptable correlation and agreement were found between the two methods (Doppler cardiac output = 0.889 thermodilution cardiac output +0.74 l/min, r = 0.975, p <0.0001).
CONCLUSION: Transgastric pulsed Doppler measurement across the left ventricular outflow tract with TEE is a very feasible and clinically acceptable method for cardiac output measurement in acutely ill patients.

Entities:  

Mesh:

Year:  1996        PMID: 8857435     DOI: 10.1007/bf01728328

Source DB:  PubMed          Journal:  Intensive Care Med        ISSN: 0342-4642            Impact factor:   17.440


  15 in total

1.  Intraoperative determination of cardiac output by transesophageal continuous wave Doppler.

Authors:  J Gorcsan; P Diana; B A Ball; B G Hattler
Journal:  Am Heart J       Date:  1992-01       Impact factor: 4.749

2.  Measurement of pulmonary blood flow with transesophageal two-dimensional and Doppler echocardiography.

Authors:  J S Savino; C A Troianos; S Aukburg; R Weiss; N Reichek
Journal:  Anesthesiology       Date:  1991-09       Impact factor: 7.892

3.  Transesophageal echocardiography with a single-plane probe. Long-axis views of the heart from the apical (transgastric) approach.

Authors:  S N Gadasalli; J S Sarnoski; J Kubota; D H Schmidt; R Gal
Journal:  Echocardiography       Date:  1992-11       Impact factor: 1.724

4.  Doppler echocardiographic measurement of mitral flow volume: validation of a new method in adult patients.

Authors:  D de Zuttere; T Touche; G Saumon; A Nitenberg; R Prasquier
Journal:  J Am Coll Cardiol       Date:  1988-02       Impact factor: 24.094

5.  Doppler echocardiographic measurement of cardiac output using the mitral orifice method.

Authors:  Y Zhang; S Nitter-Hauge; H Ihlen; E Myhre
Journal:  Br Heart J       Date:  1985-02

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

7.  Determination of cardiac output by Doppler echocardiography.

Authors:  H Ihlen; J P Amlie; J Dale; K Forfang; S Nitter-Hauge; J E Otterstad; S Simonsen; E Myhre
Journal:  Br Heart J       Date:  1984-01

8.  Pulsed Doppler transesophageal echocardiographic determination of cardiac output in human beings: comparison with thermodilution technique.

Authors:  M F Stoddard; C R Prince; N Ammash; J L Goad; R L Vogel
Journal:  Am Heart J       Date:  1993-10       Impact factor: 4.749

9.  The mitral valve orifice method for noninvasive two-dimensional echo Doppler determinations of cardiac output.

Authors:  D C Fisher; D J Sahn; M J Friedman; D Larson; L M Valdes-Cruz; S Horowitz; S J Goldberg; H D Allen
Journal:  Circulation       Date:  1983-04       Impact factor: 29.690

10.  Cardiac output by transesophageal echocardiography using continuous-wave Doppler across the aortic valve.

Authors:  P L Darmon; Z Hillel; A Mogtader; B Mindich; D Thys
Journal:  Anesthesiology       Date:  1994-04       Impact factor: 7.892

View more
  4 in total

Review 1.  Systematic review of cardiac output measurements by echocardiography vs. thermodilution: the techniques are not interchangeable.

Authors:  Mik Wetterslev; Hasse Møller-Sørensen; Rasmus Rothmann Johansen; Anders Perner
Journal:  Intensive Care Med       Date:  2016-03-01       Impact factor: 17.440

2.  Clinical monitoring of cardiac output assessed by transoesophageal echocardiography in anaesthetised dogs: a comparison with the thermodilution technique.

Authors:  Matheus M Mantovani; Denise T Fantoni; André M Gimenes; Jacqueline R de Castro; Patrícia B Flor; Keila K Ida; Denise S Schwartz
Journal:  BMC Vet Res       Date:  2017-11-09       Impact factor: 2.741

3.  Assess the clinical applicability of transthoracic echocardiography in laparotomy patients in a general intensive care unit.

Authors:  Saeed Abbasi; Kamran Fazel; Morteza Abdar Esfahani; Parviz Kashefi; Samaneh Alami Harandi
Journal:  J Res Med Sci       Date:  2014-05       Impact factor: 1.852

4.  Cardiac output measurements via echocardiography versus thermodilution: A systematic review and meta-analysis.

Authors:  Yun Zhang; Yan Wang; Jing Shi; Zhiqiang Hua; Jinyu Xu
Journal:  PLoS One       Date:  2019-10-03       Impact factor: 3.240

  4 in total