Literature DB >> 1888051

Measurement of pulmonary blood flow with transesophageal two-dimensional and Doppler echocardiography.

J S Savino1, C A Troianos, S Aukburg, R Weiss, N Reichek.   

Abstract

Transesophageal echocardiography permits measurement of the pulmonary artery diameter (two-dimensional echocardiography) and pulmonary artery blood flow velocity (pulsed-wave Doppler). These measurements considered with the heart rate allow for the determination of pulmonary artery blood flow, which is equivalent to cardiac output. This study compared the precision of transesophageal Doppler-derived cardiac output (DdCO) with the precision of thermodilution cardiac output (TdCO) and examined the agreement between DdCO and TdCO in 33 cardiac surgical patients. The proximal pulmonary artery diameter was measured in triplicate during systole and end expiration, and the local blood flow velocity was recorded on video tape. The instantaneous pulmonary artery blood flow velocity (centimeters per second) for three random cardiac beats was integrated with respect to time. DdCO was calculated as the product of the flow velocity integral (centimeters per beat), heart rate (beats per min), and the mean cross-sectional area (centimeters squared) of the main pulmonary artery. At the same time that the velocity recordings were made, three serial determinations of TdCO were made by an independent observer. Pulmonary blood flow could be measured in 25 of the 33 patients. The anatomical relationship among the esophagus, the left main stem bronchus, and the pulmonary artery did not allow adequate imaging of the pulmonary artery in 8 (24%) of the patients. A total of 45 sets of triplicate measurements were made. The range of cardiac outputs encountered was 1.7-6.6 l.min-1 by TdCO and 1.5-6.9 l.min-1 by DdCO. The 95% confidence limits for the difference between the two methods (agreement) was 0.030 +/- 0.987 l.min-1.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1991        PMID: 1888051     DOI: 10.1097/00000542-199109000-00011

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  11 in total

Review 1.  An introduction to transoesophageal echocardiography: I. Basic principles.

Authors:  F Béïque; D Joffe; S Kleiman
Journal:  Can J Anaesth       Date:  1996-03       Impact factor: 5.063

Review 2.  Transoesophageal echocardiography during liver transplantation.

Authors:  Lesley De Pietri; Federico Mocchegiani; Chiara Leuzzi; Roberto Montalti; Marco Vivarelli; Vanni Agnoletti
Journal:  World J Hepatol       Date:  2015-10-18

Review 3.  Monitoring during paediatric cardiac anaesthesia.

Authors:  J P Purday
Journal:  Can J Anaesth       Date:  1994-09       Impact factor: 5.063

4.  Can intraoperative TEE correctly measure residual shunt after surgical repair of ventricular septal defects?

Authors:  Satoshi Kurokawa; Takayuki Honma; Miki Taneoka; Hidekazu Imai; Hiroshi Baba; Minoru Nomura
Journal:  J Anesth       Date:  2010-03-13       Impact factor: 2.078

5.  Transgastric, pulsed Doppler echocardiographic determination of cardiac output.

Authors:  A Descorps-Declere; N Smail; B Vigue; J Duranteau; O Mimoz; A Edouard; K Samii
Journal:  Intensive Care Med       Date:  1996-01       Impact factor: 17.440

Review 6.  Systematic review of cardiac output measurements by echocardiography vs. thermodilution: the techniques are not interchangeable.

Authors:  Mik Wetterslev; Hasse Møller-Sørensen; Rasmus Rothmann Johansen; Anders Perner
Journal:  Intensive Care Med       Date:  2016-03-01       Impact factor: 17.440

Review 7.  Perioperative transesophageal echocardiography for non-cardiac surgery.

Authors:  Ashraf Fayad; Sasha K Shillcutt
Journal:  Can J Anaesth       Date:  2017-11-17       Impact factor: 5.063

8.  Cardiac output assessed by invasive and minimally invasive techniques.

Authors:  Allison J Lee; Jennifer Hochman Cohn; J Sudharma Ranasinghe
Journal:  Anesthesiol Res Pract       Date:  2011-07-06

Review 9.  The role of transesophageal echocardiography in the intraoperative period.

Authors:  Veronica Gouveia; Paulo Marcelino; Daniel A Reuter
Journal:  Curr Cardiol Rev       Date:  2011-08

Review 10.  Cardiac output monitoring by echocardiography: should we pass on Swan-Ganz catheters?

Authors:  A C Perrino
Journal:  Yale J Biol Med       Date:  1993 Sep-Oct
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.