Literature DB >> 6689921

Determination of cardiac output by Doppler echocardiography.

H Ihlen, J P Amlie, J Dale, K Forfang, S Nitter-Hauge, J E Otterstad, S Simonsen, E Myhre.   

Abstract

Cardiac output determined by Doppler echocardiography was compared with that determined by thermodilution at rest and during dobutamine infusion in 10 patients (group A) and by the Fick method at rest in 11 patients (group B). All patients had angina pectoris without valvular heart disease. Maximum spatial blood velocity and cross sectional aortic area were estimated by the Doppler technique and echocardiography. Cardiac output was calculated by multiplying blood velocity by aortic area at various levels in the ascending aorta. The best correlation of cardiac output between the invasive and non-invasive methods was obtained when maximum velocity in the aortic root and the aortic orifice area were used in the calculations. Cardiac output was considerably overestimated when area measurements in the aortic root were used.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6689921      PMCID: PMC482313          DOI: 10.1136/hrt.51.1.54

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  12 in total

1.  Relation between pressure and diameter in the ascending aorta of man.

Authors:  J C GREENFIELD; D J PATEL
Journal:  Circ Res       Date:  1962-05       Impact factor: 17.367

2.  Transcutaneous aortovelography. A quantitative evaluation.

Authors:  R F Sequeira; L H Light; G Cross; E B Raftery
Journal:  Br Heart J       Date:  1976-05

3.  Bayliss and Starling and the happy fellowship of physiologists.

Authors:  A V Hill
Journal:  J Physiol       Date:  1969-09       Impact factor: 5.182

4.  Diagnosis of valvular heart disease using transcutaneous Doppler ultrasound.

Authors:  A O Brubakk; B A Angelsen; L Hatle
Journal:  Cardiovasc Res       Date:  1977-09       Impact factor: 10.787

5.  Velocity patterns in the aorta.

Authors:  W A Seed; N B Wood
Journal:  Cardiovasc Res       Date:  1971-07       Impact factor: 10.787

6.  Evaluation of pulmonary and systemic blood flow by 2-dimensional Doppler echocardiography using fast Fourier transform spectral analysis.

Authors:  S J Goldberg; D J Sahn; H D Allen; L M Valdes-Cruz; H Hoenecke; Y Carnahan
Journal:  Am J Cardiol       Date:  1982-12       Impact factor: 2.778

7.  Comparison of internal diameter of great arteries in congenital heart disease. A cross-sectional echocardiographic study.

Authors:  W J Gussenhoven; B F van Leenen; W Kuis; V H de Villeneuve; N Bom; H van Meurs-van Woezik
Journal:  Br Heart J       Date:  1983-01

8.  Combined doppler and phased-array echocardiographic estimation of cardiac output.

Authors:  P A Magnin; J A Stewart; S Myers; O von Ramm; J A Kisslo
Journal:  Circulation       Date:  1981-02       Impact factor: 29.690

9.  The effect of variations of pulsed Doppler sampling site on calculation of cardiac output: an experimental study in open-chest dogs.

Authors:  D C Fisher; D J Sahn; M J Friedman; D Larson; L M Valdes-Cruz; S Horowitz; S J Goldberg; H D Allen
Journal:  Circulation       Date:  1983-02       Impact factor: 29.690

10.  Transcutaneous measurement of blood flow velocity in the human aorta.

Authors:  B A Angelsen; A O Brubakk
Journal:  Cardiovasc Res       Date:  1976-05       Impact factor: 10.787

View more
  63 in total

Review 1.  Doppler echocardiography for the estimation of cardiac output with exercise.

Authors:  Thomas Rowland; Philippe Obert
Journal:  Sports Med       Date:  2002       Impact factor: 11.136

2.  Evaluation of aortic stenosis by cardiovascular magnetic resonance imaging: comparison with established routine clinical techniques.

Authors:  C Kupfahl; M Honold; G Meinhardt; H Vogelsberg; A Wagner; H Mahrholdt; U Sechtem
Journal:  Heart       Date:  2004-08       Impact factor: 5.994

3.  Dynamics and dimensions of cardiac output changes in humans at the onset and at the end of moderate rhythmic exercise.

Authors:  M Eriksen; B A Waaler; L Walløe; J Wesche
Journal:  J Physiol       Date:  1990-07       Impact factor: 5.182

4.  [Hemodynamic evaluations of patients with small aortic annulus with St. Jude Medical prosthetic heart valve].

Authors:  T Shimabukuro; Y Takeuchi; A Gomi; H Nakatani; Y Suda; K Kono; N Nagano
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  1998-12

5.  Increased risk of heart valve regurgitation after mediastinal radiation for Hodgkin's disease: an echocardiographic study.

Authors:  M B Lund; H Ihlen; B M Voss; A F Abrahamsen; O Nome; J Kongerud; M Stugaard; K Forfang
Journal:  Heart       Date:  1996-06       Impact factor: 5.994

6.  Cardiac output by Doppler echocardiography in the premature baboon: comparison with radiolabeled microspheres.

Authors:  J P Kinsella; W R Morrow; D R Gerstmann; A F Taylor; R A deLemos
Journal:  Pediatr Cardiol       Date:  1991-04       Impact factor: 1.655

7.  Accuracy of Doppler echocardiography in the hemodynamic assessment of pulmonary hypertension.

Authors:  Micah R Fisher; Paul R Forfia; Elzbieta Chamera; Traci Housten-Harris; Hunter C Champion; Reda E Girgis; Mary C Corretti; Paul M Hassoun
Journal:  Am J Respir Crit Care Med       Date:  2009-01-22       Impact factor: 21.405

Review 8.  [Assessment of systolic function in patients with poor echogenicity: echocardiographic methods].

Authors:  F Weidemann; D Liu; M Niemann; S Herrmann; H Hu; P D Gaudron; G Ertl; K Hu
Journal:  Herz       Date:  2013-08-15       Impact factor: 1.443

9.  Changes in left ventricular stroke volume measured by Doppler echocardiography.

Authors:  H Ihlen; E Myhre; J Pamlie; K Forfang; S Larsen
Journal:  Br Heart J       Date:  1985-10

10.  Sustained cardiac diastolic changes elicited by ultrafiltration in patients with moderate congestive heart failure: pathophysiological correlates.

Authors:  M Pepi; G C Marenzi; P G Agostoni; E Doria; P Barbier; M Muratori; F Celeste; M D Guazzi
Journal:  Br Heart J       Date:  1993-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.