Literature DB >> 8843383

T2 maximum likelihood estimation from multiple spin-echo magnitude images.

J M Bonny1, M Zanca, J Y Boire, A Veyre.   

Abstract

An optimal maximum likelihood (ML) method is described for an unbiased estimation of monoexponential T2 from magnitude spin-echo images. The algorithm is based on a Gaussian assumption of noise distribution. The validity of this assumption was checked by a statistical chi 2 test on spin-echo and fast low-angle shot surface coil images. Monte-Carlo simulations of magnitude data showed that the ML estimate standard deviation is lower than that produced by a weighted least-squares fitting on signal logarithm. Correction schemes are proposed to reduce bias deriving from magnitude reconstruction. The variance of the ML estimate converged rapidly toward the theoretical algebraic expression of the Cramér-Rao lower bound.

Mesh:

Year:  1996        PMID: 8843383     DOI: 10.1002/mrm.1910360216

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  22 in total

Review 1.  Magnetic resonance imaging quantification of liver iron.

Authors:  Claude B Sirlin; Scott B Reeder
Journal:  Magn Reson Imaging Clin N Am       Date:  2010-08       Impact factor: 2.266

Review 2.  Errors in quantitative T1rho imaging and the correction methods.

Authors:  Weitian Chen
Journal:  Quant Imaging Med Surg       Date:  2015-08

3.  Fast quantitative parameter maps without fitting: Integration yields accurate mono-exponential signal decay rates.

Authors:  Ruitian Song; Ralf B Loeffler; Joseph L Holtrop; M Beth McCarville; Jane S Hankins; Claudia M Hillenbrand
Journal:  Magn Reson Med       Date:  2017-10-30       Impact factor: 4.668

4.  A variable echo-number method for estimating R2 in MRI-based polymer gel dosimetry.

Authors:  Yoichi Watanabe; Hitoshi Kubo
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

5.  Incorporation of Rician noise in the analysis of biexponential transverse relaxation in cartilage using a multiple gradient echo sequence at 3 and 7 Tesla.

Authors:  Mustapha Bouhrara; David A Reiter; Hasan Celik; Jean-Marie Bonny; Vanessa Lukas; Kenneth W Fishbein; Richard G Spencer
Journal:  Magn Reson Med       Date:  2014-02-28       Impact factor: 4.668

6.  Optimizing MR Scan Design for Model-Based ${T}_{1}$ , ${T}_{2}$ Estimation From Steady-State Sequences.

Authors:  Gopal Nataraj; Jon-Fredrik Nielsen; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2016-10-04       Impact factor: 10.048

7.  Fisher information and Cramér-Rao lower bound for experimental design in parallel imaging.

Authors:  Mustapha Bouhrara; Richard G Spencer
Journal:  Magn Reson Med       Date:  2017-11-01       Impact factor: 4.668

8.  Calculating T2 in images from a phased array receiver.

Authors:  Peter A Hardy; Anders H Andersen
Journal:  Magn Reson Med       Date:  2009-04       Impact factor: 4.668

9.  Fast approximation to pixelwise relaxivity maps: validation in iron overloaded subjects.

Authors:  Antonella Meloni; Heather Zmyewski; Hugh Young Rienhoff; Amber Jones; Alessia Pepe; Massimo Lombardi; John C Wood
Journal:  Magn Reson Imaging       Date:  2013-06-15       Impact factor: 2.546

10.  Phase-aligned multiple spin-echo averaging: a simple way to improve signal-to-noise ratio of in vivo mouse spinal cord diffusion tensor image.

Authors:  Tsang-Wei Tu; Matthew D Budde; Mingqiang Xie; Ying-Jr Chen; Qing Wang; James D Quirk; Sheng-Kwei Song
Journal:  Magn Reson Imaging       Date:  2014-08-01       Impact factor: 2.546

View more