Literature DB >> 10628687

Two-dimensional deghosting for EPI.

F Hennel1.   

Abstract

A residual ghost artefact in echo-planar imaging (EPI) remains after the standard correction procedure based on a 1-dimensional phase-modulation of the spectra of even or odd echoes. A better reduction of this artefact is demonstrated using a 2-dimensional phase correction. The phase correction map is measured inside the ghost-free region of the image, preferably in a reference scan with an increased field of view, as the phase difference between complex images reconstructed separately from even and odd echoes. An extrapolated map consisting of spatial components up to the second order (constant, x, y, xy and x2-y2) is then found by a fit to the measured values. This map is used to correct the phase of even- and odd-reconstructed images before adding them. This procedure may cause some spatially dependent loss of signal, but if the level of the residual artefact is less than 20% of the image intensity, such losses are negligible.

Mesh:

Year:  1999        PMID: 10628687     DOI: 10.1007/bf02594610

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  3 in total

1.  Image reconstruction for echo planar imaging with nonequidistant k-space sampling.

Authors:  H Bruder; H Fischer; H E Reinfelder; F Schmitt
Journal:  Magn Reson Med       Date:  1992-02       Impact factor: 4.668

2.  Artifact reduction in EPI with phase-encoded reference scan.

Authors:  X Hu; T H Le
Journal:  Magn Reson Med       Date:  1996-07       Impact factor: 4.668

3.  Interleaved echo planar imaging on a standard MRI system.

Authors:  K Butts; S J Riederer; R L Ehman; R M Thompson; C R Jack
Journal:  Magn Reson Med       Date:  1994-01       Impact factor: 4.668

  3 in total
  4 in total

1.  Phase and amplitude correction for multi-echo water-fat separation with bipolar acquisitions.

Authors:  Huanzhou Yu; Ann Shimakawa; Charles A McKenzie; Wenmiao Lu; Scott B Reeder; R Scott Hinks; Jean H Brittain
Journal:  J Magn Reson Imaging       Date:  2010-05       Impact factor: 4.813

Review 2.  Prospective motion correction in functional MRI.

Authors:  Maxim Zaitsev; Burak Akin; Pierre LeVan; Benjamin R Knowles
Journal:  Neuroimage       Date:  2016-11-11       Impact factor: 6.556

3.  MR phase imaging with bipolar acquisition.

Authors:  Joseph Dagher; Kambiz Nael
Journal:  NMR Biomed       Date:  2016-05-05       Impact factor: 4.044

4.  Joint correction of Nyquist artifact and minuscule motion-induced aliasing artifact in interleaved diffusion weighted EPI data using a composite two-dimensional phase correction procedure.

Authors:  Hing-Chiu Chang; Nan-Kuei Chen
Journal:  Magn Reson Imaging       Date:  2016-04-22       Impact factor: 2.546

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.