Literature DB >> 8718950

Finite element stress analysis of a hybrid fracture fixation plate.

S J Ferguson1, U P Wyss, D R Pichora.   

Abstract

Metal plates are commonly used in the operative treatment of bone fractures. Rigid metal plates stabilize the fracture site, maintain good contact between bone fragments and allow early weight bearing and patient mobility. However, treatment with rigid metal plates can cause localized bone atrophy due to stress-shielding and interference with blood circulation, and the weakened bone can refracture after plate removal. A hybrid bone plate system that combines the torsional and bending rigidity of a metal plate with the axial compliance of a polymer insert has been designed. A three-dimensional, quarter-symmetric finite element model was generated for a canine femur diaphysis plated with this metal/polymer hybrid design. A model with a standard metal fixation plate was also generated for comparison purposes. The stress state in the underlying bone was examined for several loading conditions taken from published in vivo studies. The finite element model was used to study the performance of biodegradable polymer inserts in the plate system. The flexible plate reduced stress-shielding effects at the fracture site when subjected to an axial load. The bending strength of the plate was not compromised by the addition of the polymer inserts. Biodegradable inserts further enhanced the performance of the new plate design, transferring less of the axial load to the plate as the inserts broke down.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8718950     DOI: 10.1016/1350-4533(95)00041-0

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  11 in total

Review 1.  Computational techniques for the assessment of fracture repair.

Authors:  Donald D Anderson; Thaddeus P Thomas; Ana Campos Marin; Jacob M Elkins; William D Lack; Damien Lacroix
Journal:  Injury       Date:  2014-06       Impact factor: 2.586

2.  Computational modelling of long bone fractures fixed with locking plates - How can the risk of implant failure be reduced?

Authors:  M Nassiri; B Macdonald; J M O'Byrne
Journal:  J Orthop       Date:  2013-03-07

3.  Composites for bone repair: phosphate glass fibre reinforced PLA with varying fibre architecture.

Authors:  I Ahmed; I A Jones; A J Parsons; J Bernard; J Farmer; C A Scotchford; G S Walker; C D Rudd
Journal:  J Mater Sci Mater Med       Date:  2011-06-14       Impact factor: 3.896

4.  The Influence of Static Load and Sideways Impact Fall on Extramedullary Bone Plates Used to Treat Intertrochanteric Femoral Fracture: A Preclinical Strength Assessment.

Authors:  Pratik Nag; Bhaskar Borgohain; Kashif Akhtar Ahmed; Pranjal Phukan; Neeraj Kumar; Alireza Borjali; Kartik Mangudi Varadarajan; Souptick Chanda
Journal:  Ann Biomed Eng       Date:  2022-07-12       Impact factor: 4.219

5.  PLGA bone plates reinforced with crosslinked PPF.

Authors:  V Hasirci; A E Litman; D J Trantolo; J D Gresser; D L Wise; H C Margolis
Journal:  J Mater Sci Mater Med       Date:  2002-02       Impact factor: 3.896

6.  Degradable phosphate glass fiber reinforced polymer matrices: mechanical properties and cell response.

Authors:  Delia S Brauer; Christian Rüssel; Sebastian Vogt; Jürgen Weisser; Matthias Schnabelrauch
Journal:  J Mater Sci Mater Med       Date:  2007-06-21       Impact factor: 3.896

7.  Novel Design of Minimal Incision Double Oblique Device for Osteosynthesis (DODO) of Hip: Results of an In-silico Study Based on the Femur Morphometrics of the Northeast (NE) Indian population.

Authors:  Pratik Nag; Bhaskar Borgohain; Souptick Chanda
Journal:  Indian J Orthop       Date:  2021-05-05       Impact factor: 1.251

8.  Long-term Evaluation Using Finite Element Analysis of Bone Atrophy Changes after Locking Plate Fixation of Forearm Diaphyseal Fracture.

Authors:  Tetsuya Hirashima; Yusuke Matsuura; Takane Suzuki; Tomoyo Akasaka; Aya Kanazuka; Seiji Ohtori
Journal:  J Hand Surg Glob Online       Date:  2021-06-14

9.  A preclinical model of post-surgery secondary bone healing for subtrochanteric femoral fracture based on fuzzy interpretations.

Authors:  Pratik Nag; Souptick Chanda
Journal:  PLoS One       Date:  2022-07-21       Impact factor: 3.752

10.  In vitro and in vivo evaluations of nano-hydroxyapatite/polyamide 66/glass fibre (n-HA/PA66/GF) as a novel bioactive bone screw.

Authors:  Bao Su; Xiaohua Peng; Dianming Jiang; Jun Wu; Bo Qiao; Weichao Li; Xiaotong Qi
Journal:  PLoS One       Date:  2013-07-08       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.