Literature DB >> 34306552

Novel Design of Minimal Incision Double Oblique Device for Osteosynthesis (DODO) of Hip: Results of an In-silico Study Based on the Femur Morphometrics of the Northeast (NE) Indian population.

Pratik Nag1, Bhaskar Borgohain2, Souptick Chanda1.   

Abstract

BACKGROUND: Hip fractures account for a large proportion of hospitalization among the trauma cases. Low cost, simple technique, easy removal, and high rate of the bone union makes extramedullary (EM) fixation techniques a preferred choice. A close-fit bone and plate are essential for the success of such implantation. Various studies have found femur morphometry being related to regional features and social differences. Most of the available commercial implants are developed based on the data of the Caucasian population.
METHODS: In the herein study, a novel design, Double Oblique Device for Osteosynthesis of hip (DODO), is proposed while considering the regional morphometry of the Northeast (NE) population of India. This study employs finite element (FE) analysis to compare the biomechanical outcome of the new device with that of proximal femoral locking plate (PFLP) and variable angle dynamic hip screw (VA-DHS) on a femur having an Evans type-I intertrochanteric fracture.
RESULTS: The stress shielding was substantially high for the PFLP and VA-DHS in the distal bone fragment (lateral aspect) and for DODO in the femoral head. The difference in axial displacement between the post-implanted DODO-fixed femur and its respective intact femur was predicted to be almost the same as that of PFLP-fixed femur and its respective intact femur.
CONCLUSION: The computational results found the new device to be a viable alternative to the conventional plating techniques, especially for the NE population of India, and predicted better to comparable biomechanical characteristics. © Indian Orthopaedics Association 2021.

Entities:  

Keywords:  Extracapsular hip fracture; Finite element analysis; Oblique screw orientation; Osteosynthesis; Stress shielding

Year:  2021        PMID: 34306552      PMCID: PMC8275691          DOI: 10.1007/s43465-021-00408-3

Source DB:  PubMed          Journal:  Indian J Orthop        ISSN: 0019-5413            Impact factor:   1.251


  30 in total

1.  A study of Korean femoral geometry.

Authors:  Gon Khang; Kuiwon Choi; Cheol-Sang Kim; Jong Soo Yang; Tae-Soo Bae
Journal:  Clin Orthop Relat Res       Date:  2003-01       Impact factor: 4.176

2.  Oblique screws at the plate ends increase the fixation strength in synthetic bone test medium.

Authors:  Karl Stoffel; Gwidon Stachowiak; Thomas Forster; André Gächter; Markus Kuster
Journal:  J Orthop Trauma       Date:  2004-10       Impact factor: 2.512

3.  Protection from stress in bone and its effects. Experiments with stainless steel and plastic plates in dogs.

Authors:  A J Tonino; C L Davidson; P J Klopper; L A Linclau
Journal:  J Bone Joint Surg Br       Date:  1976-02

4.  Biomechanical design prognosis of two extramedullary fixation devices for subtrochanteric femur fracture: a finite element study.

Authors:  Pratik Nag; Souptick Chanda
Journal:  Med Biol Eng Comput       Date:  2021-01-08       Impact factor: 2.602

5.  Clinical features and walking ability in the early postoperative period after treatment of trochanteric hip fractures. Results with special reference to fracture type and surgical treatment.

Authors:  L A Broström; C Barrios; M Kronberg; A Stark; G Walheim
Journal:  Ann Chir Gynaecol       Date:  1992

6.  Anthropometric measurements to design best-fit femoral stem for the Indian population.

Authors:  Br Rawal; Rahul Ribeiro; Rajesh Malhotra; Naresh Bhatnagar
Journal:  Indian J Orthop       Date:  2012-01       Impact factor: 1.251

7.  Comparing the Intramedullary Nailing Method Versus Dynamic Hip Screw in Treatment of Unstable Intertrochanteric Fractures.

Authors:  Ali Yeganeh; Roozbeh Taghavi; Mehdi Moghtadaei
Journal:  Med Arch       Date:  2016-01-31

8.  A review of tip apex distance in dynamic hip screw fixation of osteoporotic hip fractures.

Authors:  Imran Haruna Abdulkareem
Journal:  Niger Med J       Date:  2012-10

9.  Assessment of the geometry of proximal femur for short cephalomedullary nail placement: An observational study in dry femora and living subjects.

Authors:  Devendra Pathrot; Rehan Ul Haq; Aditya N Aggarwal; Mahindra Nagar; Shuchi Bhatt
Journal:  Indian J Orthop       Date:  2016 May-Jun       Impact factor: 1.251

10.  Biomechanical comparison between standard and inclined screw orientation in dynamic hip screw side-plate fixation: The lift-off phenomenon.

Authors:  Ivan Zderic; Gaston C Willhuber; Marc-Daniel Ahrend; Florian Gras; Jorge Barla; Carlos Sancineto; Markus Windolf; Geoff Richards; Boyko Gueorguiev
Journal:  J Orthop Translat       Date:  2018-11-17       Impact factor: 5.191

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.