Literature DB >> 15348134

Comparative wear under four different tribological conditions of acetylene enhanced cross-linked ultra high molecular weight polyethylene.

H Marrs1, D C Barton, R A Jones, I M Ward, J Fisher, C Doyle.   

Abstract

In this study, the wear of ultra high molecular weight polyethylene (UHMWPE) (Grade RCH 1000) crosslinked by gamma irradiation in acetylene was compared to virgin (non-irradiated) UHMWPE using four different wear configurations: (i) unidirectional motion with a smooth counterface, (ii) multidirectional motion with a smooth counterface, (iii) unidirectional motion with a rough counterface and (iv) multidirectional motion with a rough counterface. Copyright 1999 Kluwer Academic Publishers

Entities:  

Year:  1999        PMID: 15348134     DOI: 10.1023/a:1026469522868

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  6 in total

1.  Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups.

Authors:  B M Wroblewski; P D Siney; D Dowson; S N Collins
Journal:  J Bone Joint Surg Br       Date:  1996-03

2.  Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses.

Authors:  A Wang; C Stark; J H Dumbleton
Journal:  Proc Inst Mech Eng H       Date:  1996       Impact factor: 1.617

3.  The influence of scratches to metallic counterfaces on the wear of ultra-high molecular weight polyethylene.

Authors:  J Fisher; P Firkins; E A Reeves; J L Hailey; G H Isaac
Journal:  Proc Inst Mech Eng H       Date:  1995       Impact factor: 1.617

4.  Quantitative comparison of wear debris from UHMWPE that has and has not been sterilised by gamma irradiation.

Authors:  A A Besong; J L Tipper; E Ingham; M H Stone; B M Wroblewski; J Fisher
Journal:  J Bone Joint Surg Br       Date:  1998-03

5.  A study of the combined effects of shelf ageing following irradiation in air and counterface roughness on the wear of UHMWPE.

Authors:  A A Besong; J L Hailey; E Ingham; M Stone; B M Wroblewski; J Fisher
Journal:  Biomed Mater Eng       Date:  1997       Impact factor: 1.300

6.  The causes of femoral head roughening in explanted Charnley hip prostheses.

Authors:  G H Isaac; J R Atkinson; D Dowson; P D Kennedy; M R Smith
Journal:  Eng Med       Date:  1987-07
  6 in total
  9 in total

1.  The effect of molecular orientation and acetylene-enhanced crosslinking on the wear of UHMWPE in total artificial joints.

Authors:  H Marrs; D C Barton; C Doyle; R A Jones; E L Lewis; I M Ward; J Fisher
Journal:  J Mater Sci Mater Med       Date:  2001-07       Impact factor: 3.896

2.  [Ligament instability in total knee arthroplasty--causal analysis].

Authors:  H Graichen; M Strauch; T Katzhammer; L Zichner; R von Eisenhart-Rothe
Journal:  Orthopade       Date:  2007-07       Impact factor: 1.087

Review 3.  Biological response to prosthetic debris.

Authors:  Diana Bitar; Javad Parvizi
Journal:  World J Orthop       Date:  2015-03-18

4.  Carbon-carbon composite bearing materials in hip arthroplasty: analysis of wear and biological response to wear debris.

Authors:  G I Howling; E Ingham; H Sakoda; T D Stewart; J Fisher; A Antonarulrajah; S Appleyard; B Rand
Journal:  J Mater Sci Mater Med       Date:  2004-01       Impact factor: 3.896

5.  The effect of accelerated aging on the wear of UHMWPE.

Authors:  H Sakoda; J Fisher; S Lu; F Buchanan
Journal:  J Mater Sci Mater Med       Date:  2001 Oct-Dec       Impact factor: 3.896

6.  Enhanced wear performance of ultra high molecular weight polyethylene crosslinked by organosilane.

Authors:  C Y Tang; X L Xie; X C Wu; R K Y Li; Y W Mai
Journal:  J Mater Sci Mater Med       Date:  2002-11       Impact factor: 3.896

7.  Wear of fixed bearing and rotating platform mobile bearing knees subjected to high levels of internal and external tibial rotation.

Authors:  H M McEwen; J Fisher; A A Goldsmith; D D Auger; C Hardaker; M H Stone
Journal:  J Mater Sci Mater Med       Date:  2001 Oct-Dec       Impact factor: 3.896

8.  A Comparison of the Clinical and Radiographic Results of Press Fit Condylar Rotating-Platform High-Flexion and Low Contact Stress Mobile Bearing Prosthesis in Total Knee Arthroplasty: Short term Results.

Authors:  Shin Woo Nam; Yong Seuk Lee; Ji Hoon Kwak; Nam Ki Kim; Beom Koo Lee
Journal:  Knee Surg Relat Res       Date:  2012-02-28

9.  Fixed or mobile-bearing total knee arthroplasty.

Authors:  Chun-Hsiung Huang; Jiann-Jong Liau; Cheng-Kung Cheng
Journal:  J Orthop Surg Res       Date:  2007-01-05       Impact factor: 2.359

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.