Literature DB >> 8524025

Simultaneous calculation of flow and diffusion sensitivity in steady-state free precession imaging.

H Gudbjartsson1, S Patz.   

Abstract

In this paper the authors quantitatively evaluate the combined effect of both flow and diffusion in steady-state free precession (SSFP) imaging. A partition analysis (PA) is used to derive a fourth order approximation (in E2) of the signal in an echo SSFP sequence. The authors also introduce a novel very fast simulation technique, based on a circular convolution, which accurately accounts for both flow and diffusion. A 2D SSFP-echo sequence was implemented to obtain experimental data from a phantom containing three different solutions. Excellent agreement between the theory and the experimental data was found. Then by using the simulation algorithm and experimental measurements of in vivo brain motion, the authors estimated the artifacts to be expected in SSFP diffusion imaging of the brain and found them to be comparable with those of pulsed gradient spin echo. Finally, the authors point out the equivalence between the flow sensitivity of SSFP and RF spoiling commonly used in fast imaging.

Mesh:

Substances:

Year:  1995        PMID: 8524025      PMCID: PMC2204061          DOI: 10.1002/mrm.1910340413

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  25 in total

1.  FLASH imaging: rapid NMR imaging using low flip-angle pulses. 1986.

Authors:  A Haase; J Frahm; D Matthaei; W Hänicke; K-D Merboldt
Journal:  J Magn Reson       Date:  2011-12       Impact factor: 2.229

2.  Analysis of the higher-order echoes in SSFP.

Authors:  D J Kim; Z H Cho
Journal:  Magn Reson Med       Date:  1991-05       Impact factor: 4.668

3.  Multiple echo SSFP sequences.

Authors:  C T Mizumoto; E Yoshitome
Journal:  Magn Reson Med       Date:  1991-03       Impact factor: 4.668

4.  Motion-insensitive, steady-state free precession imaging.

Authors:  Y Zur; M L Wood; L J Neuringer
Journal:  Magn Reson Med       Date:  1990-12       Impact factor: 4.668

5.  Steady-state magnetizations in rapid NMR imaging using small flip angles and short repetition intervals.

Authors:  K Sekihara
Journal:  IEEE Trans Med Imaging       Date:  1987       Impact factor: 10.048

6.  Application of missing pulse steady state free precession to the study of renal microcirculation.

Authors:  M E Stromski; H R Brady; S R Gullans; S Patz
Journal:  Magn Reson Med       Date:  1991-07       Impact factor: 4.668

7.  Missing pulse steady-state free precession.

Authors:  S Patz; S T Wong; M S Roos
Journal:  Magn Reson Med       Date:  1989-05       Impact factor: 4.668

8.  Fast imaging of CSF flow/motion patterns using steady-state free precession (SSFP).

Authors:  F A Jolesz; S Patz; R C Hawkes; I Lopez
Journal:  Invest Radiol       Date:  1987-10       Impact factor: 6.016

9.  Elimination of transverse coherences in FLASH MRI.

Authors:  A P Crawley; M L Wood; R M Henkelman
Journal:  Magn Reson Med       Date:  1988-11       Impact factor: 4.668

10.  Pulsatile motion artifact reduction in 3D steady-state-free-precession-echo brain imaging.

Authors:  R D Tien; M Bernstein; J MacFall
Journal:  Magn Reson Imaging       Date:  1993       Impact factor: 2.546

View more
  6 in total

Review 1.  Foundations of advanced magnetic resonance imaging.

Authors:  Roland Bammer; Stefan Skare; Rexford Newbould; Chunlei Liu; Vincent Thijs; Stefan Ropele; David B Clayton; Gunnar Krueger; Michael E Moseley; Gary H Glover
Journal:  NeuroRx       Date:  2005-04

2.  Real-time correction of rigid body motion-induced phase errors for diffusion-weighted steady-state free precession imaging.

Authors:  Rafael O'Halloran; Murat Aksoy; Eric Aboussouan; Eric Peterson; Anh Van; Roland Bammer
Journal:  Magn Reson Med       Date:  2014-04-08       Impact factor: 4.668

3.  Line scan diffusion imaging of the spine.

Authors:  Roland Bammer; Andreas M Herneth; Stephan E Maier; Kim Butts; Rupert W Prokesch; Huy M Do; Scott W Atlas; Michael E Moseley
Journal:  AJNR Am J Neuroradiol       Date:  2003-01       Impact factor: 3.825

4.  Vessel-wall imaging and quantification of flow-mediated dilation using water-selective 3D SSFP-echo.

Authors:  Michael C Langham; Cheng Li; Erin K Englund; Erica N Chirico; Emile R Mohler; Thomas F Floyd; Felix W Wehrli
Journal:  J Cardiovasc Magn Reson       Date:  2013-10-30       Impact factor: 5.364

5.  Modeling an equivalent b-value in diffusion-weighted steady-state free precession.

Authors:  Benjamin C Tendler; Sean Foxley; Michiel Cottaar; Saad Jbabdi; Karla L Miller
Journal:  Magn Reson Med       Date:  2020-01-10       Impact factor: 4.668

6.  Robust 3D Bloch-Siegert based B 1 + mapping using multi-echo general linear modeling.

Authors:  Nadège Corbin; Julio Acosta-Cabronero; Shaihan J Malik; Martina F Callaghan
Journal:  Magn Reson Med       Date:  2019-07-18       Impact factor: 4.668

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.