Literature DB >> 24715414

Real-time correction of rigid body motion-induced phase errors for diffusion-weighted steady-state free precession imaging.

Rafael O'Halloran1, Murat Aksoy, Eric Aboussouan, Eric Peterson, Anh Van, Roland Bammer.   

Abstract

PURPOSE: Diffusion contrast in diffusion-weighted steady-state free precession magnetic resonance imaging (MRI) is generated through the constructive addition of signal from many coherence pathways. Motion-induced phase causes destructive interference which results in loss of signal magnitude and diffusion contrast. In this work, a three-dimensional (3D) navigator-based real-time correction of the rigid body motion-induced phase errors is developed for diffusion-weighted steady-state free precession MRI.
METHODS: The efficacy of the real-time prospective correction method in preserving phase coherence of the steady state is tested in 3D phantom experiments and 3D scans of healthy human subjects.
RESULTS: In nearly all experiments, the signal magnitude in images obtained with proposed prospective correction was higher than the signal magnitude in images obtained with no correction. In the human subjects, the mean magnitude signal in the data was up to 30% higher with prospective motion correction than without. Prospective correction never resulted in a decrease in mean signal magnitude in either the data or in the images.
CONCLUSIONS: The proposed prospective motion correction method is shown to preserve the phase coherence of the steady state in diffusion-weighted steady-state free precession MRI, thus mitigating signal magnitude losses that would confound the desired diffusion contrast.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  diffusion; diffusion tensor imaging (DTI); diffusion-weighted imaging (DWI); motion-correction; navigation; phase; steady-state free precession

Mesh:

Year:  2014        PMID: 24715414      PMCID: PMC4190128          DOI: 10.1002/mrm.25159

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  21 in total

1.  Online motion correction for diffusion-weighted imaging using navigator echoes: Application to RARE imaging without sensitivity loss.

Authors:  D G Norris; W Driesel
Journal:  Magn Reson Med       Date:  2001-05       Impact factor: 4.668

2.  Sampling density compensation in MRI: rationale and an iterative numerical solution.

Authors:  J G Pipe; P Menon
Journal:  Magn Reson Med       Date:  1999-01       Impact factor: 4.668

3.  Online motion correction for diffusion-weighted segmented-EPI and FLASH imaging.

Authors:  K S Weih; W Driesel; M von Mengershausen; D G Norris
Journal:  MAGMA       Date:  2004-03-29       Impact factor: 2.310

4.  Propeller EPI in the other direction.

Authors:  Stefan Skare; Rexford D Newbould; Dave B Clayton; Roland Bammer
Journal:  Magn Reson Med       Date:  2006-06       Impact factor: 4.668

5.  Fast three dimensional magnetic resonance imaging.

Authors:  P Irarrazabal; D G Nishimura
Journal:  Magn Reson Med       Date:  1995-05       Impact factor: 4.668

6.  Simultaneous calculation of flow and diffusion sensitivity in steady-state free precession imaging.

Authors:  H Gudbjartsson; S Patz
Journal:  Magn Reson Med       Date:  1995-10       Impact factor: 4.668

7.  Simultaneous estimation of T(2) and apparent diffusion coefficient in human articular cartilage in vivo with a modified three-dimensional double echo steady state (DESS) sequence at 3 T.

Authors:  Ernesto Staroswiecki; Kristin L Granlund; Marcus T Alley; Garry E Gold; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2011-12-16       Impact factor: 4.668

8.  Navigated diffusion imaging of normal and ischemic human brain.

Authors:  A J de Crespigny; M P Marks; D R Enzmann; M E Moseley
Journal:  Magn Reson Med       Date:  1995-05       Impact factor: 4.668

9.  3D diffusion tensor MRI with isotropic resolution using a steady-state radial acquisition.

Authors:  Youngkyoo Jung; Alexey A Samsonov; Walter F Block; Mariana Lazar; Aiming Lu; Jing Liu; Andrew L Alexander
Journal:  J Magn Reson Imaging       Date:  2009-05       Impact factor: 4.813

10.  Steady-state diffusion-weighted imaging of in vivo knee cartilage.

Authors:  Karla L Miller; Brian A Hargreaves; Garry E Gold; John M Pauly
Journal:  Magn Reson Med       Date:  2004-02       Impact factor: 4.668

View more
  1 in total

1.  Analysis of phase error effects in multishot diffusion-prepared turbo spin echo imaging.

Authors:  Anh T Van; Barbara Cervantes; Hendrik Kooijman; Dimitrios C Karampinos
Journal:  Quant Imaging Med Surg       Date:  2017-04
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.