Literature DB >> 3429171

Fast imaging of CSF flow/motion patterns using steady-state free precession (SSFP).

F A Jolesz1, S Patz, R C Hawkes, I Lopez.   

Abstract

Using a rapid Fourier SSFP imaging technique, which is sensitive to slow flow (approximately 1 mm/sec) in the plane of the image, we obtained 135 brain MRI examinations. The CSF flow/motion patterns were mapped by two images with orthogonal in plane flow sensitivity directions. Analysis showed significant deviations from the "normal" pattern in ventricular enlargements because of obstruction (no evidence of CSF flow/motion) or in normal pressure hydrocephalus (complex, intensive flow pattern in lateral ventricles) suggesting a diagnostic potential for this fast imaging technique.

Entities:  

Mesh:

Year:  1987        PMID: 3429171     DOI: 10.1097/00004424-198710000-00001

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  7 in total

1.  CSF flow imaging in the management of third ventriculostomy with a reversed fast imaging with steady-state precession sequence.

Authors:  Karl T Hoffmann; Thomas N Lehmann; Clemens Baumann; Roland Felix
Journal:  Eur Radiol       Date:  2002-12-13       Impact factor: 5.315

2.  Colour-coded echographic flow imaging and spectral analysis of cerebrospinal fluid (CSF) in infants. Part II. CSF-dynamics.

Authors:  P Winkler
Journal:  Pediatr Radiol       Date:  1992

3.  CSF flow studies of intracranial cysts and cyst-like lesions achieved using reversed fast imaging with steady-state precession MR sequences.

Authors:  K T Hoffmann; N Hosten; B U Meyer; S Röricht; C Sprung; J Oellinger; M Gutberlet; R Felix
Journal:  AJNR Am J Neuroradiol       Date:  2000-03       Impact factor: 3.825

Review 4.  Quantification in peripheral angiography.

Authors:  D P Harrington; K Kandarpa
Journal:  Cardiovasc Intervent Radiol       Date:  1987       Impact factor: 2.740

5.  Simultaneous calculation of flow and diffusion sensitivity in steady-state free precession imaging.

Authors:  H Gudbjartsson; S Patz
Journal:  Magn Reson Med       Date:  1995-10       Impact factor: 4.668

6.  Phase-cycled simultaneous multislice balanced SSFP imaging with CAIPIRINHA for efficient banding reduction.

Authors:  Yi Wang; Xingfeng Shao; Thomas Martin; Steen Moeller; Essa Yacoub; Danny J J Wang
Journal:  Magn Reson Med       Date:  2015-12-15       Impact factor: 4.668

7.  Diffusion MRI reveals in vivo and non-invasively changes in astrocyte function induced by an aquaporin-4 inhibitor.

Authors:  Clement Debaker; Boucif Djemai; Luisa Ciobanu; Tomokazu Tsurugizawa; Denis Le Bihan
Journal:  PLoS One       Date:  2020-05-15       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.