Literature DB >> 18230442

Steady-state magnetizations in rapid NMR imaging using small flip angles and short repetition intervals.

K Sekihara.   

Abstract

The steady-state magnetizations in three versions of rapid NMR imaging using small flip angles and short repetition intervals are studied. It is shown that in the original version, the estimation using (1 - E(1)) sin alpha/(1 - E(1) cos alpha) contains errors that depend on the increment of the phase rotation angle arising from the phase encoding process. The modified version of rapid imaging, where the phase rotation due to the phase encoding process is compensated for in each time interval, can have sensitivity superior to the original version where the phase rotation is not compensated for. Here, flip angles larger than the Ernst angle must be used. In the third version, the steady-state magnetization is obtained by a rapid imaging sequence in which the phase rotations arising not only from the application of the phase encoding gradient but also from the applications of other gradients are compensated for. Analysis of this version showed a remarkable increase in sensitivity although it required the use of an extremely uniform field. It is estimated that this increase reaches 80 percent with a repetition interval of 10 ms, although a field uniformity less than 1 muT is necessary.

Entities:  

Year:  1987        PMID: 18230442     DOI: 10.1109/TMI.1987.4307816

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  42 in total

1.  Multishot EPI-SSFP in the heart.

Authors:  Daniel A Herzka; Peter Kellman; Anthony H Aletras; Michael A Guttman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2002-04       Impact factor: 4.668

2.  Phased array ghost elimination (PAGE) for segmented SSFP imaging with interrupted steady-state.

Authors:  Peter Kellman; Michael A Guttman; Daniel A Herzka; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2002-12       Impact factor: 4.668

3.  Artifact suppression in imaging of myocardial infarction using B1-weighted phased-array combined phase-sensitive inversion recovery.

Authors:  Peter Kellman; Christopher K Dyke; Anthony H Aletras; Elliot R McVeigh; Andrew E Arai
Journal:  Magn Reson Med       Date:  2004-02       Impact factor: 4.668

4.  Myocardial tagging with SSFP.

Authors:  Daniel A Herzka; Michael A Guttman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

5.  Signal-to-noise ratio behavior of steady-state free precession.

Authors:  Scott B Reeder; Daniel A Herzka; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2004-07       Impact factor: 4.668

6.  TrueFisp versus HASTE sequences in 3T cine MRI: Evaluation of image quality during phonation in patients with velopharyngeal insufficiency.

Authors:  Christiane Kulinna-Cosentini; Christian Czerny; Arnulf Baumann; Michael Weber; Klaus Sinko
Journal:  Eur Radiol       Date:  2015-11-28       Impact factor: 5.315

7.  Single heartbeat cardiac tagging for the evaluation of transient phenomena.

Authors:  Daniel A Herzka; J Andrew Derbyshire; Peter Kellman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2005-12       Impact factor: 4.668

8.  S5FP: spectrally selective suppression with steady state free precession.

Authors:  J A Derbyshire; D A Herzka; E R McVeigh
Journal:  Magn Reson Med       Date:  2005-10       Impact factor: 4.668

9.  MR ventriculocisternography by using 3D balanced steady-state free precession imaging: technical note.

Authors:  Ming-Long Wu; Cheng-Wen Ko; Ting-Yi Chen; Ming-Ting Wu; Hsiao-Wen Chung; Teng-Yi Huang; Yi-Ru Lin
Journal:  AJNR Am J Neuroradiol       Date:  2005-05       Impact factor: 3.825

10.  Computational cardiac anatomy using MRI.

Authors:  Mirza Faisal Beg; Patrick A Helm; Elliot McVeigh; Michael I Miller; Raimond L Winslow
Journal:  Magn Reson Med       Date:  2004-11       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.