Literature DB >> 8438739

Diagnostic accuracy of seismocardiography compared with electrocardiography for the anatomic and physiologic diagnosis of coronary artery disease during exercise testing.

R A Wilson1, V S Bamrah, J Lindsay, M Schwaiger, J Morganroth.   

Abstract

A multicenter study was performed to compare the diagnostic accuracy of a new technique, seismocardiography, with that of electrocardiography for physiologically and anatomically significant ischemic coronary artery disease (CAD) during exercise stress testing. Five participating centers enrolled 129 patients who had simultaneous seismocardiograms and 12-lead electrocardiograms at the time of their exercise treadmill stress tests. Two different definitions of CAD were used: anatomic and physiologically significant disease. The presence of anatomically significant CAD (> or = 50% diameter stenosis) was documented by coronary angiography. Physiologically significant CAD was defined as present in the same 129 patients when coronary arteriography (> or = 50% diameter stenosis) and thallium-201 scintigraphy (defect on initial postexercise images) were both abnormal. Seismocardiography had a significantly better sensitivity for detecting anatomic CAD than did electrocardiography (73 vs 48%; p < 0.001), without loss of specificity (78 vs 80%; p = NS). Exercise seismocardiography added significant incremental diagnostic information beyond that provided by exercise electrocardiography. Seismocardiography was more sensitive (without less specificity) in women and in patients who did not achieve maximal predicted heart rate. In patients with physiologically significant CAD, the seismocardiogram was also significantly more sensitive (78%) than was the electrocardiogram (55%) (p < 0.02), without loss of specificity (84 vs 74%). Seismocardiography significantly improved sensitivity for the detection of anatomic and physiologic CAD. It is easy to perform and may be a clinically useful adjunct in exercise stress testing.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8438739     DOI: 10.1016/0002-9149(93)90508-a

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  11 in total

1.  The seismocardiogram as magnetic-field-compatible alternative to the electrocardiogram for cardiac stress monitoring.

Authors:  M Jerosch-Herold; J Zanetti; H Merkle; L Poliac; H Huang; A Mansoor; F Zhao; N Wilke
Journal:  Int J Card Imaging       Date:  1999-12

2.  Simplified detection of myocardial ischemia by seismocardiography. Differentiation between causes of altered myocardial function.

Authors:  M Becker; A B Roehl; U Siekmann; A Koch; M de la Fuente; R Roissant; K Radermacher; N Marx; M Hein
Journal:  Herz       Date:  2013-06-23       Impact factor: 1.443

3.  Seismocardiography and 4D flow MRI reveal impact of aortic valve replacement on chest acceleration and aortic hemodynamics.

Authors:  Ethan M I Johnson; Mozziyar Etemadi; S Chris Malaisrie; Patrick M McCarthy; Michael Markl; Alex J Barker
Journal:  J Card Surg       Date:  2019-10-15       Impact factor: 1.620

4.  An Adaptive Seismocardiography (SCG)-ECG Multimodal Framework for Cardiac Gating Using Artificial Neural Networks.

Authors:  Jingting Yao; S Tridandapani; W F Auffermann; C A Wick; P T Bhatti
Journal:  IEEE J Transl Eng Health Med       Date:  2018-10-08       Impact factor: 3.316

5.  A Wearable Patch to Enable Long-Term Monitoring of Environmental, Activity and Hemodynamics Variables.

Authors:  Mozziyar Etemadi; Omer T Inan; J Alex Heller; Sinan Hersek; Liviu Klein; Shuvo Roy
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2015-05-12       Impact factor: 3.833

6.  Usefulness of seismocardiography for the diagnosis of ischemia in patients with coronary artery disease.

Authors:  Iwona Korzeniowska-Kubacka; Maria Bilińska; Ryszard Piotrowicz
Journal:  Ann Noninvasive Electrocardiol       Date:  2005-07       Impact factor: 1.468

7.  Modeling Consistent Dynamics of Cardiogenic Vibrations in Low-Dimensional Subspace.

Authors:  Jonathan Zia; Jacob Kimball; Sinan Hersek; Omer T Inan
Journal:  IEEE J Biomed Health Inform       Date:  2020-03-16       Impact factor: 5.772

8.  Precision wearable accelerometer contact microphones for longitudinal monitoring of mechano-acoustic cardiopulmonary signals.

Authors:  Pranav Gupta; Mohammad J Moghimi; Yaesuk Jeong; Divya Gupta; Omer T Inan; Farrokh Ayazi
Journal:  NPJ Digit Med       Date:  2020-02-12

9.  Can Seismocardiogram Fiducial Points Be Used for the Routine Estimation of Cardiac Time Intervals in Cardiac Patients?

Authors:  Zeynep Melike Işilay Zeybek; Vittorio Racca; Antonio Pezzano; Monica Tavanelli; Marco Di Rienzo
Journal:  Front Physiol       Date:  2022-03-18       Impact factor: 4.566

10.  Artifact Noise Removal Techniques on Seismocardiogram Using Two Tri-Axial Accelerometers.

Authors:  Loc Luu; Anh Dinh
Journal:  Sensors (Basel)       Date:  2018-04-02       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.