Literature DB >> 16029378

Usefulness of seismocardiography for the diagnosis of ischemia in patients with coronary artery disease.

Iwona Korzeniowska-Kubacka1, Maria Bilińska, Ryszard Piotrowicz.   

Abstract

BACKGROUND: Seismocardiography (SCG) is a useful method for the detection of exercise-induced changes in cardiac muscle contractility which may occur during myocardial ischemia. The aim of this study was to compare the diagnostic accuracy of SCG with electrocardiographic exercise test (ETT) for diagnosis of ischemia in patients with angiographically proved coronary artery disease (CAD).
METHODS: Seventy-seven male patients with CAD without myocardial infarction (MI), mean age 51+/-9 years, were subjected to SCG and ETT. A gender-matched control group consisted of 30 healthy volunteers aged 34+/-7 years. SCG was done simultaneously with resting supine 12-lead electrocardiography before and immediately after a symptom-limited ETT. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) of SCG were compared with ETT. Moreover, the diagnostic accuracy of both the methods was compared, with coronary angiography being the reference for the analysis.
RESULTS: SCG was more sensitive (61.1% vs 44.2%, P<0.05) and accurate (70% vs 61%, P<0.05) method for detecting ischemia caused by coronary stenosis>or=50%, at least in one coronary artery compared to the ETT. However, ETT had better specificity than SCG (82.4% vs 76%, P<0.05). The PPV and NPV of SCG were significantly better than those obtained with ETT (77.9% vs 76%, P<0.05 and 63.4% vs 53.8%, P<0.05, respectively). Moreover, the concordant results of SCG and ETT improved the diagnostic accuracy of both methods.
CONCLUSIONS: SCG appeared to be more sensitive for detecting ischemia caused by more than>or=50% stenosis of the main coronary artery compared to an electrocardiographic stress test. SCG was a useful ETT adjunct for selecting patients requiring coronary angiography.

Entities:  

Mesh:

Year:  2005        PMID: 16029378      PMCID: PMC6932138          DOI: 10.1111/j.1542-474X.2005.00547.x

Source DB:  PubMed          Journal:  Ann Noninvasive Electrocardiol        ISSN: 1082-720X            Impact factor:   1.468


  5 in total

1.  Seismocardiographic changes associated with obstruction of coronary blood flow during balloon angioplasty.

Authors:  D M Salerno; J M Zanetti; L A Green; M R Mooney; J D Madison; R A Van Tassel
Journal:  Am J Cardiol       Date:  1991-07-15       Impact factor: 2.778

2.  Seismocardiography is not a new term.

Authors:  S Zoneraich
Journal:  Am J Cardiol       Date:  1992-02-15       Impact factor: 2.778

3.  The impact of selection bias on measurement of noninvasive test accuracy.

Authors:  D M Salerno; K Wang; I F Goldenberg; R A Van Tassel
Journal:  Am J Cardiol       Date:  1993-07-15       Impact factor: 2.778

4.  Diagnostic accuracy of seismocardiography compared with electrocardiography for the anatomic and physiologic diagnosis of coronary artery disease during exercise testing.

Authors:  R A Wilson; V S Bamrah; J Lindsay; M Schwaiger; J Morganroth
Journal:  Am J Cardiol       Date:  1993-03-01       Impact factor: 2.778

5.  Seismocardiography for monitoring changes in left ventricular function during ischemia.

Authors:  D M Salerno; J Zanetti
Journal:  Chest       Date:  1991-10       Impact factor: 9.410

  5 in total
  8 in total

1.  Simplified detection of myocardial ischemia by seismocardiography. Differentiation between causes of altered myocardial function.

Authors:  M Becker; A B Roehl; U Siekmann; A Koch; M de la Fuente; R Roissant; K Radermacher; N Marx; M Hein
Journal:  Herz       Date:  2013-06-23       Impact factor: 1.443

Review 2.  Devices in heart failure: potential methods for device-based monitoring of congestive heart failure.

Authors:  Shahzeb M Munir; Roberta C Bogaev; Ed Sobash; K J Shankar; Sreedevi Gondi; Igor V Stupin; Jillian Robertson; M Alan Brewer; S Ward Casscells; Reynolds M Delgado; Amany Ahmed
Journal:  Tex Heart Inst J       Date:  2008

3.  Unified frame of reference improves inter-subject variability of seismocardiograms.

Authors:  Mikko Paukkunen; Petteri Parkkila; Raimo Kettunen; Raimo Sepponen
Journal:  Biomed Eng Online       Date:  2015-02-26       Impact factor: 2.819

4.  Automatic Identification of Systolic Time Intervals in Seismocardiogram.

Authors:  Ghufran Shafiq; Sivanagaraja Tatinati; Wei Tech Ang; Kalyana C Veluvolu
Journal:  Sci Rep       Date:  2016-11-22       Impact factor: 4.379

5.  Classification of aortic stenosis using conventional machine learning and deep learning methods based on multi-dimensional cardio-mechanical signals.

Authors:  Chenxi Yang; Banish D Ojha; Nicole D Aranoff; Philip Green; Negar Tavassolian
Journal:  Sci Rep       Date:  2020-10-16       Impact factor: 4.379

6.  Heart Rate Variability Analysis on Electrocardiograms, Seismocardiograms and Gyrocardiograms on Healthy Volunteers.

Authors:  Szymon Sieciński; Paweł S Kostka; Ewaryst J Tkacz
Journal:  Sensors (Basel)       Date:  2020-08-13       Impact factor: 3.576

7.  Detecting Coronary Artery Disease Using Rest Seismocardiography and Gyrocardiography.

Authors:  Parastoo Dehkordi; Erwin P Bauer; Kouhyar Tavakolian; Zhen G Xiao; Andrew P Blaber; Farzad Khosrow-Khavar
Journal:  Front Physiol       Date:  2021-12-02       Impact factor: 4.566

8.  Force plate monitoring of human hemodynamics.

Authors:  Jan Kríz; Petr Seba
Journal:  Nonlinear Biomed Phys       Date:  2008-02-22
  8 in total