Literature DB >> 31614028

Seismocardiography and 4D flow MRI reveal impact of aortic valve replacement on chest acceleration and aortic hemodynamics.

Ethan M I Johnson1, Mozziyar Etemadi2, S Chris Malaisrie3, Patrick M McCarthy3, Michael Markl4, Alex J Barker5.   

Abstract

Aortic valve replacement (AVR) is a common treatment for severe aortic valve disease, which can adversely affect blood flow in the aorta. Seismocardiography (SCG) measures physical vibrations at the exterior of the chest, which can be sensitive to altered cardiac function and flow dynamics. Magnetic resonance imaging (MRI) can image blood movement, and it can provide depiction and quantification of aortic flow. Here we present SCG and MRI measurements from before and after AVR and ascending aorta replacement, in the case of a woman with bicuspid aortic valve disease and a dilated ascending aorta. SCG measurements show elevated energy during systole indicating stenotic flow before surgery and lowered systolic energy levels after replacement with a prosthetic valve. MRI shows jetting, helical flow before surgery, and cohesive flow after.
© 2019 Wiley Periodicals, Inc.

Entities:  

Keywords:  aorta and great vessels; bicuspid aortic valve; magnetic resonance imaging (MRI); seismocardiography (SCG); valve repair/replacement

Mesh:

Year:  2019        PMID: 31614028      PMCID: PMC6948186          DOI: 10.1111/jocs.14289

Source DB:  PubMed          Journal:  J Card Surg        ISSN: 0886-0440            Impact factor:   1.620


  6 in total

1.  A Wearable Patch to Enable Long-Term Monitoring of Environmental, Activity and Hemodynamics Variables.

Authors:  Mozziyar Etemadi; Omer T Inan; J Alex Heller; Sinan Hersek; Liviu Klein; Shuvo Roy
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2015-05-12       Impact factor: 3.833

2.  Reduction of aberrant aortic haemodynamics following aortic root replacement with a mechanical valved conduit.

Authors:  Eric J Keller; S Chris Malaisrie; Jane Kruse; Patrick M McCarthy; James C Carr; Michael Markl; Alex J Barker; Jeremy D Collins
Journal:  Interact Cardiovasc Thorac Surg       Date:  2016-05-30

3.  Diagnostic accuracy of seismocardiography compared with electrocardiography for the anatomic and physiologic diagnosis of coronary artery disease during exercise testing.

Authors:  R A Wilson; V S Bamrah; J Lindsay; M Schwaiger; J Morganroth
Journal:  Am J Cardiol       Date:  1993-03-01       Impact factor: 2.778

4.  Seismocardiography for monitoring changes in left ventricular function during ischemia.

Authors:  D M Salerno; J Zanetti
Journal:  Chest       Date:  1991-10       Impact factor: 9.410

Review 5.  Role of Cardiac Magnetic Resonance Imaging in Valvular Heart Disease: Diagnosis, Assessment, and Management.

Authors:  Roshin C Mathew; Adrián I Löffler; Michael Salerno
Journal:  Curr Cardiol Rep       Date:  2018-09-26       Impact factor: 2.931

6.  Perioperative evaluation of regional aortic wall shear stress patterns in patients undergoing aortic valve and/or proximal thoracic aortic replacement.

Authors:  Emilie Bollache; Paul W M Fedak; Pim van Ooij; Ozair Rahman; S Chris Malaisrie; Patrick M McCarthy; James C Carr; Alex Powell; Jeremy D Collins; Michael Markl; Alex J Barker
Journal:  J Thorac Cardiovasc Surg       Date:  2017-11-16       Impact factor: 5.209

  6 in total
  2 in total

1.  Flow dynamics of surgical and transcatheter aortic valves: Past to present.

Authors:  Hoda Hatoum; Sunyoung Ahn; Scott Lilly; Pablo Maureira; Juan Crestanello; Vinod H Thourani; Lakshmi Prasad Dasi
Journal:  JTCVS Open       Date:  2022-01-24

Review 2.  Precordial Vibrations: A Review of Wearable Systems, Signal Processing Techniques, and Main Applications.

Authors:  Francesca Santucci; Daniela Lo Presti; Carlo Massaroni; Emiliano Schena; Roberto Setola
Journal:  Sensors (Basel)       Date:  2022-08-03       Impact factor: 3.847

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.