Literature DB >> 8430191

Abdominal MR imaging: comparison of T2-weighted fast and conventional spin-echo, and contrast-enhanced fast multiplanar spoiled gradient-recalled imaging.

R N Low1, I R Francis, J S Sigeti, T K Foo.   

Abstract

T2-weighted fast and conventional spin-echo (SE) and dynamic gadolinium-enhanced fast multiplanar spoiled gradient-recalled (FMPSPGR) images in 26 patients (18 with hepatic masses and eight with no detected abnormality) were compared to determine the efficacy of the newer pulse sequences (fast SE and FMPSPGR) in abdominal imaging. FMPSPGR allows for breath-hold magnetic resonance imaging of the liver. The contrast-to-noise ratio (C/N) of the hepatic lesions was calculated for each sequence and was superior in fast SE compared with that in conventional SE in 16 of 18 patients. Lesion detection was 90% with fast SE and was 85% and 80% for conventional SE and contrast material-enhanced FMPSPGR sequences, respectively. Of the T2-weighted sequences, fast SE showed consistently sharper anatomic structures and less respiratory and cardiac motion artifact. Thus, fast SE (with its superior C/N and shorter imaging time) and gadolinium-enhanced FMPSPGR images, when combined, demonstrate potential value as routine sequences in abdominal imaging.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8430191     DOI: 10.1148/radiology.186.3.8430191

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  9 in total

1.  Congenital bronchobiliary fistula: MRI appearance.

Authors:  Jon S Hourigan; Michael G Carr; Edward M Burton; Joel C Ledbetter
Journal:  Pediatr Radiol       Date:  2003-11-07

2.  [Sequences in MRI. Part II].

Authors:  F Schick
Journal:  Radiologe       Date:  2006-09       Impact factor: 0.635

3.  Multishot PROPELLER for high-field preclinical MRI.

Authors:  Prachi Pandit; Yi Qi; Jennifer Story; Kevin F King; G Allan Johnson
Journal:  Magn Reson Med       Date:  2010-07       Impact factor: 4.668

4.  MR imaging of focal liver lesions: comparison between turbo spin-echo and conventional spin-echo pulse sequences.

Authors:  A Giovagnoni; E Paci; P Ercolani; B Kiefer; P Santino; A Piga
Journal:  MAGMA       Date:  1995 Sep-Dec       Impact factor: 2.310

5.  Detection of colorectal liver metastases: a prospective multicenter trial comparing unenhanced MRI, MnDPDP-enhanced MRI, and spiral CT.

Authors:  Carlo Bartolozzi; Francescamaria Donati; Dania Cioni; Carlo Procacci; Giovanni Morana; Antonio Chiesa; Luigi Grazioli; Giorgio Cittadini; Giuseppe Cittadini; Andrea Giovagnoni; Giovanni Gandini; Jochen Maass; Riccardo Lencioni
Journal:  Eur Radiol       Date:  2003-08-09       Impact factor: 5.315

6.  Liver MR imaging: comparison of respiratory triggered fast spin echo with T2-weighted spin-echo and inversion recovery.

Authors:  M T Keogan; C E Spritzer; E K Paulson; S S Paine; L Harris; J L Dahlke; J R MacFall
Journal:  Abdom Imaging       Date:  1996 Sep-Oct

7.  Hepatic MR imaging: comparison of RARE derived sequences with conventional sequences for detection and characterization of focal liver lesions.

Authors:  P Reimer; E J Rummeny; M Wissing; G M Bongartz; G Schuierer; P E Peters
Journal:  Abdom Imaging       Date:  1996 Sep-Oct

8.  Detection of colorectal liver metastases: prospective comparison of unenhanced and ferumoxides-enhanced magnetic resonance imaging at 1.5 T, dual-phase spiral CT, and spiral CT during arterial portography.

Authors:  R Lencioni; F Donati; D Cioni; A Paolicchi; A Cicorelli; C Bartolozzi
Journal:  MAGMA       Date:  1998-12       Impact factor: 2.310

9.  Sensitivity of T2-weighted FSE sequences towards physiological iron depositions in normal brains at 1.5 and 3.0 T.

Authors:  T Allkemper; W Schwindt; D Maintz; W Heindel; B Tombach
Journal:  Eur Radiol       Date:  2004-03-19       Impact factor: 5.315

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.