Imaging of the human torso using cone-beam transmission CT implemented on a rotating gamma camera.

S H Manglos1, D A Bassano, F D Thomas, Z D Grossman.   

Abstract

Radionuclide transmission CT generated on a rotating gamma camera can improve SPECT imaging by providing attenuation maps for attenuation compensation and for anatomical correlation. This paper demonstrates the feasibility and high quality of cone-beam transmission CT (CB-CT) of human subjects, in comparison to conventional parallel-ray CT, and evaluates some possible imaging protocols. Two CB-CT implementation modes, with a cone-beam collimator and without any collimator, were evaluated. Three human subjects of different dimensions were imaged. For the two smaller subjects, the CB-CT images were dramatically superior, in terms of noise and resolution, to those obtained with a parallel-ray geometry. The image noise was less by a factor of 6. CB-CT linear attenuation coefficients were found to be in close agreement with published values for various tissues. For the largest subject, image truncation produced a ring artifact at the edge, but inside the artifact, the image quality was still very good. Cone-beam images obtained without any collimator were acceptable, but photon scatter degraded the image contrast.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1730983

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  4 in total

1.  Estimation of attenuation maps from scatter and photopeak window single photon-emission computed tomographic images of technetium 99m-labeled sestamibi.

Authors:  T S Pan; M A King; D S Luo; S T Dahlberg; B J Villegas
Journal:  J Nucl Cardiol       Date:  1997 Jan-Feb       Impact factor: 5.952

2.  Emission-based attenuation correction of myocardial perfusion studies.

Authors:  M T Madsen; P T Kirchner; M Grover-McKay; R Aktay; J S Seabold; K Rezai; G Kelly
Journal:  J Nucl Cardiol       Date:  1997 Nov-Dec       Impact factor: 5.952

Review 3.  Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 1. Impact of attenuation and methods of estimating attenuation maps.

Authors:  M A King; B M Tsui; T S Pan
Journal:  J Nucl Cardiol       Date:  1995 Nov-Dec       Impact factor: 5.952

4.  Improvement of brain single photon emission tomography (SPET) using transmission data acquisition in a four-head SPET scanner.

Authors:  K Murase; S Tanada; T Inoue; Y Sugawara; K Hamamoto
Journal:  Eur J Nucl Med       Date:  1993-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.