Literature DB >> 8599965

Simultaneous emission and transmission measurements as an adjunct to dynamic planar gamma camera studies.

D L Bailey1, M Robinson, S R Meikle, P T Bye.   

Abstract

Anatomical imaging provides useful information which complements functional imaging performed using a gamma camera. We have previously used transmission measurements in single-photon emission tomography acquired simultaneously with the emission scan using either a plane flood source or a moving line source for attenuation and scatter correction. This approach is equally applicable in planar imaging and provides useful information to assist in detecting patient motion and in defining regions of interest in dynamic studies. We have adapted a moving transmission line source to acquire dynamic geometric mean measurements in the study of the mucociliary clearance of inhaled technetium-99m labelled colloids with a single-headed rotating gamma camera. The line source makes a return pass for each emission acquisition frame (alternating anterior/posterior views), each pass being initiated by a signal from the gamma camera. The result is a dynamic sequence of emission and transmission measurements obtained from a single acquisition. In this application transmission measurements are used to define the lung outline for clearance determination and to check for subject movement throughout the duration of the study.

Entities:  

Mesh:

Year:  1996        PMID: 8599965     DOI: 10.1007/bf00837632

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  32 in total

1.  Comparisons of planar and tomographic gamma scintigraphy to measure the penetration index of inhaled aerosols.

Authors:  P R Phipps; I Gonda; D L Bailey; P Borham; G Bautovich; S D Anderson
Journal:  Am Rev Respir Dis       Date:  1989-06

2.  Dynamic geometric mean studies using a single headed rotating gamma camera.

Authors:  D L Bailey; R R Fulton; C B Jackson; B F Hutton; J G Morris
Journal:  J Nucl Med       Date:  1989-11       Impact factor: 10.057

3.  Pulmonary mucociliary clearance in cystic fibrosis.

Authors:  J Sanchis; M Dolovich; C Rossman; W Wilson; M Newhouse
Journal:  N Engl J Med       Date:  1973-03-29       Impact factor: 91.245

4.  Nonisotropic attenuation in SPECT: phantom tests of quantitative effects and compensation techniques.

Authors:  S H Manglos; R J Jaszczak; C E Floyd; L J Hahn; K L Greer; R E Coleman
Journal:  J Nucl Med       Date:  1987-10       Impact factor: 10.057

5.  A transmission-dependent method for scatter correction in SPECT.

Authors:  S R Meikle; B F Hutton; D L Bailey
Journal:  J Nucl Med       Date:  1994-02       Impact factor: 10.057

6.  Absolute quantitation of radiotracer uptake in the lungs using a gamma camera.

Authors:  D J Macey; R Marshall
Journal:  J Nucl Med       Date:  1982-08       Impact factor: 10.057

7.  Gamma camera emission tomography. Development and properties of a multi-sectional emission computed tomography system.

Authors:  S A Larsson
Journal:  Acta Radiol Suppl       Date:  1980

8.  Correction for tissue attenuation in radionuclide gastric emptying studies: a comparison of a lateral image method and a geometric mean method.

Authors:  P J Collins; M Horowitz; D J Shearman; B E Chatterton
Journal:  Br J Radiol       Date:  1984-08       Impact factor: 3.039

9.  Quantitative profile scanning for the measurement of organ radioactivity.

Authors:  P Tothill; J M Galt
Journal:  Phys Med Biol       Date:  1971-10       Impact factor: 3.609

10.  Transmission scanning: a useful adjunct to conventional emission scanning for accurately keying isotope deposition to radiographic anatomy.

Authors:  D E Kuhl; J Hale; W L Eaton
Journal:  Radiology       Date:  1966-08       Impact factor: 11.105

View more
  3 in total

1.  EANM-EORTC general recommendations for sentinel node diagnostics in melanoma.

Authors:  Annette H Chakera; Birger Hesse; Zeynep Burak; James R Ballinger; Allan Britten; Corrado Caracò; Alistair J Cochran; Martin G Cook; Krzysztof T Drzewiecki; Richard Essner; Einat Even-Sapir; Alexander M M Eggermont; Tanja Gmeiner Stopar; Christian Ingvar; Martin C Mihm; Stanley W McCarthy; Nicola Mozzillo; Omgo E Nieweg; Richard A Scolyer; Hans Starz; John F Thompson; Giuseppe Trifirò; Giuseppe Viale; Sergi Vidal-Sicart; Roger Uren; Wendy Waddington; Arturo Chiti; Alain Spatz; Alessandro Testori
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-10       Impact factor: 9.236

2.  Effect of increasing doses of hypertonic saline on mucociliary clearance in patients with cystic fibrosis.

Authors:  M Robinson; A L Hemming; J A Regnis; A G Wong; D L Bailey; G J Bautovich; M King; P T Bye
Journal:  Thorax       Date:  1997-10       Impact factor: 9.139

3.  Breath-hold CT attenuation correction for quantitative cardiac SPECT.

Authors:  Kazuhiro Koshino; Kazuhito Fukushima; Masaji Fukumoto; Kazunari Sasaki; Tetsuaki Moriguchi; Yuki Hori; Tsutomu Zeniya; Yoshihiro Nishimura; Keisuke Kiso; Hidehiro Iida
Journal:  EJNMMI Res       Date:  2012-06-22       Impact factor: 3.138

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.