Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty.

M H Oswald1, R P Jakob, E Schneider, H M Hoogewoud.   

Abstract

Alignment of the anatomical and mechanical axes of the lower extremities was analyzed using standardized radiographs in two series of 66 femur and 44 tibia specimens. A new anatomical axis, the distal femoral anatomical axis, was introduced. This axis corresponds to the overall femoral anatomical axis and encloses a valgus angle of 6 degrees with the mechanical axis of the femur. It allows for design of shorter intramedullary guiding instruments that will still be in congruency with true femur geometry. Comparison with computerized calculations of angles on computed tomography scans on a series of 38 bones shows a high precision of measurement on standard radiographs in neutral rotation.

Entities:  

Mesh:

Year:  1993        PMID: 8409995     DOI: 10.1016/s0883-5403(06)80042-2

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  51 in total

1.  Prosthetic alignment and sizing in computer-assisted total knee arthroplasty.

Authors:  Tomoyuki Matsumoto; Nobuhiro Tsumura; Masahiro Kurosaka; Hirotsugu Muratsu; Ryosuke Kuroda; Katsuhiko Ishimoto; Kazuo Tsujimoto; Ryoichi Shiba; Shinichi Yoshiya
Journal:  Int Orthop       Date:  2004-08-14       Impact factor: 3.075

2.  Intraoperative assessment of resected condyle thickness in total knee arthroplasty.

Authors:  Dae Kyung Bae; Sang Jun Song; Kyoung Ho Yoon; Jung Ho Noh; Chul Hee Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-12-24       Impact factor: 4.342

3.  Change in limb length after high tibial osteotomy using computer-assisted surgery: a comparative study of closed- and open-wedge osteotomies.

Authors:  Dae Kyung Bae; Sang Jun Song; Hwan Jin Kim; Jae Wan Seo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-01-20       Impact factor: 4.342

Review 4.  Alignment outcomes in navigated total knee arthroplasty: a meta-analysis.

Authors:  Yonghui Fu; Mingming Wang; Yifeng Liu; Qin Fu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-15       Impact factor: 4.342

5.  The accuracy of intramedullary tibial guide of sagittal alignment of PCL-substituting total knee arthroplasty.

Authors:  Hyuk-Soo Han; Seung-Baik Kang; Chris H Jo; Sun-Hong Kim; Jung-Ha Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-05-08       Impact factor: 4.342

6.  Sagittal alignment of the lower extremity while standing in female.

Authors:  Ryo Sugama; Yukihide Minoda; Akio Kobayashi; Hiroyoshi Iwaki; Mitsuhiko Ikebuchi; Yusuke Hashimoto; Kunio Takaoka; Hiroaki Nakamura
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-04-21       Impact factor: 4.342

7.  [Is computer navigation a useful tool in unicompartmental knee arthroplasty? A pilot cadaver study].

Authors:  P R Aldinger; H S Gill; U Schlegel; M Schneider; M Clauss; J W Goodfellow; D W Murray; S J Breusch
Journal:  Orthopade       Date:  2005-11       Impact factor: 1.087

8.  The accuracy of extramedullary guides for tibial component placement in total knee arthroplasty.

Authors:  K Y Chiu; W P Yau; T P Ng; W M Tang
Journal:  Int Orthop       Date:  2007-03-16       Impact factor: 3.075

9.  Computer-assisted alignment system for tibial component placement in total knee replacement: a radiological study.

Authors:  Alfonso Manzotti; Chris Pullen; Norberto Confalonieri
Journal:  Chir Organi Mov       Date:  2008-02-10

10.  TKA sagittal alignment with navigation systems and conventional techniques vary only a few degrees.

Authors:  Yukihide Minoda; Akio Kobayashi; Hiroyoshi Iwaki; Hirotsugu Ohashi; Kunio Takaoka
Journal:  Clin Orthop Relat Res       Date:  2008-08-20       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.