Literature DB >> 20454779

The accuracy of intramedullary tibial guide of sagittal alignment of PCL-substituting total knee arthroplasty.

Hyuk-Soo Han1, Seung-Baik Kang, Chris H Jo, Sun-Hong Kim, Jung-Ha Lee.   

Abstract

Experimental and clinical studies on the accuracy of the intramedullary alignment method have produced different results, and few have addressed accuracy in the sagittal plane. Reported deviations are not only attributable to the alignment method but also to radiological errors. The purpose of this study was to evaluate the accuracy of the intramedullary alignment method in the sagittal plane using computed tomography (CT) and 3-dimensional imaging software. Thirty-one TKAs were performed using an intramedullary alignment method involving the insertion of a long 8-mm diameter rod into the medullary canal to the distal metaphysis of the tibia. All alignment instruments were set to achieve an ideal varus/valgus angle of 0° in the coronal plane and a tibial slope of 0° in the sagittal plane. The accuracy of the intramedullary alignment system was assessed by measuring the coronal tibial component angle and sagittal tibial slope angles, i.e., angles between the tibial anatomical axis and the tangent to the medial and lateral tibial plateau or the cut-surface. The mean coronal tibial component angle was 88.5° ± 1.2° and the mean tibial component slope in the sagittal plane was 1.6° ± 1.2° without anterior slope. Our intramedullary tibial alignment method, which involves passing an 8-mm diameter long rod through the tibial shaft isthmus, showed good accuracy (less than 3 degrees of variation and no anterior slope) in the sagittal plane in neutral or varus knees.

Entities:  

Mesh:

Year:  2010        PMID: 20454779     DOI: 10.1007/s00167-010-1152-y

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  35 in total

1.  How accurate is current TKR instrumentation?

Authors:  S David Stulberg
Journal:  Clin Orthop Relat Res       Date:  2003-11       Impact factor: 4.176

2.  Extramedullary or intramedullary tibial alignment guides: a randomised, prospective trial of radiological alignment.

Authors:  S Anand; J W K Harrison; K A Buch
Journal:  J Bone Joint Surg Br       Date:  2003-09

3.  Extramedullary or intramedullary tibial alignment guides: a randomised, prospective trial of radiological alignment.

Authors:  M R Reed; W Bliss; J L Sher; K P Emmerson; S M G Jones; P F Partington
Journal:  J Bone Joint Surg Br       Date:  2002-08

4.  The accuracy of tibial intramedullary alignment devices in total knee arthroplasty.

Authors:  E D Simmons; J A Sullivan; S Rackemann; R D Scott
Journal:  J Arthroplasty       Date:  1991-03       Impact factor: 4.757

5.  Extramedullary versus intramedullary tibial alignment guides for total knee arthroplasty.

Authors:  Steven J Rottman; Michael Dvorkin; David Gold
Journal:  Orthopedics       Date:  2005-12       Impact factor: 1.390

6.  Measurement of lower limb alignment using long radiographs.

Authors:  J G Wright; N Treble; A R Feinstein
Journal:  J Bone Joint Surg Br       Date:  1991-09

7.  A quantitative approach to radiography of the lower limb. Principles and applications.

Authors:  T D Cooke; R A Scudamore; J T Bryant; C Sorbie; D Siu; B Fisher
Journal:  J Bone Joint Surg Br       Date:  1991-09

8.  Alignment deviation between bone resection and final implant positioning in computer-navigated total knee arthroplasty.

Authors:  Fabio Catani; Nicola Biasca; Andrea Ensini; Alberto Leardini; Luca Bianchi; Vitantonio Digennaro; Sandro Giannini
Journal:  J Bone Joint Surg Am       Date:  2008-04       Impact factor: 5.284

9.  Blood-gas and circulatory changes during total knee replacement. Role of the intramedullary alignment rod.

Authors:  N R Fahmy; H P Chandler; K Danylchuk; E B Matta; N Sunder; J M Siliski
Journal:  J Bone Joint Surg Am       Date:  1990-01       Impact factor: 5.284

10.  Comparative experience with intramedullary and extramedullary alignment in total knee arthroplasty.

Authors:  G A Engh; T L Petersen
Journal:  J Arthroplasty       Date:  1990-03       Impact factor: 4.757

View more
  4 in total

1.  Effect of medial tibial torsion on the sagittal alignment of lower legs in patients with medial knee osteoarthritis.

Authors:  Atsushi Takahashi; Toshimi Aizawa; Takashi Aki; Mitsuhiro Kashiwaba; Masayuki Kamimura; Shin Hitachi; Eiji Itoi
Journal:  Surg Radiol Anat       Date:  2012-09-06       Impact factor: 1.246

2.  The entry point of intramedullary tibia cutting guide should vary according to the individual tibia morphology in TKA.

Authors:  Sung-Mok Oh; Seong-Il Bin; Bum-Sik Lee; Jong-Min Kim
Journal:  Arch Orthop Trauma Surg       Date:  2019-12-16       Impact factor: 3.067

3.  The accuracy of the extramedullary and intramedullary femoral alignment system in total knee arthroplasty for varus osteoarthritic knee.

Authors:  Woon-hwa Jung; Chung-woo Chun; Ji-hoon Lee; Jae-hun Ha; Jae-Heon Jeong
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-04-08       Impact factor: 4.342

4.  Incidence of deep vein thrombosis before and after total knee arthroplasty without pharmacologic prophylaxis: a 128-row multidetector CT indirect venography study.

Authors:  Moon Jong Chang; Min Kyu Song; Min Gyu Kyung; Jae Hoon Shin; Chong Bum Chang; Seung-Baik Kang
Journal:  BMC Musculoskelet Disord       Date:  2018-07-31       Impact factor: 2.362

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.