Literature DB >> 22198358

Intraoperative assessment of resected condyle thickness in total knee arthroplasty.

Dae Kyung Bae1, Sang Jun Song, Kyoung Ho Yoon, Jung Ho Noh, Chul Hee Lee.   

Abstract

PURPOSE: The purpose of this study was to assess the use of resected condyle thickness measurement, obtained with caliper, when verifying the accuracy of distal femoral bone resection in total knee arthroplasty.
METHODS: Fifty-two total knee arthroplasties were performed to treat osteoarthritis with varus knee. The difference of caliper-measured thickness of resected medial and lateral femoral condyles after removal of cartilage from the lateral condyle was compared with radiographically measured values. The preoperative planned valgus cut angles and the postoperative femoral component valgus angles were compared.
RESULTS: The difference of radiograph-measured thickness averaged 2.4 ± 2.2 mm and the difference of caliper-measured thickness averaged 2.0 ± 2.1 mm (r = 0.735, P < 0.001). The postoperative femoral component valgus angle averaged 4.8° ± 1.6° (range, 2.0°-7.6°). The difference between the valgus cut angle and femoral component valgus angle averaged -0.3° ± 1.5°.
CONCLUSIONS: The confirmation of correspondence between the caliper-measured and radiographically measured thickness of resected condyles could verify the accuracy of distal femoral bone resection in total knee arthroplasty. LEVEL OF EVIDENCE: III.

Entities:  

Mesh:

Year:  2011        PMID: 22198358     DOI: 10.1007/s00167-011-1843-z

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  33 in total

1.  How accurate is current TKR instrumentation?

Authors:  S David Stulberg
Journal:  Clin Orthop Relat Res       Date:  2003-11       Impact factor: 4.176

2.  Bone cutting errors in total knee arthroplasty.

Authors:  Christopher Plaskos; Antony J Hodgson; Kevin Inkpen; Robert W McGraw
Journal:  J Arthroplasty       Date:  2002-09       Impact factor: 4.757

3.  Intraoperative cutting errors in total knee arthroplasty.

Authors:  H Bäthis; L Perlick; M Tingart; C Perlick; C Lüring; J Grifka
Journal:  Arch Orthop Trauma Surg       Date:  2004-11-09       Impact factor: 3.067

4.  Native femoral sulcus as a guide for the position of the femoral component in primary total knee arthroplasty: a prospective comparative study of 420 knees.

Authors:  Fang-Yao Chiu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-08-26       Impact factor: 4.342

Review 5.  Component alignment in total knee arthroplasty.

Authors:  James Benjamin
Journal:  Instr Course Lect       Date:  2006

6.  Computerized tomography scout view for determining distal femoral resection angle in intramedullary instrumentation of total knee arthroplasty.

Authors:  M Murad Uslu; Baris Ozsar; Meric Cirpar; Simay Kara; Fatih Eksioglu; Ozgur Cetik
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-08-22       Impact factor: 4.342

7.  Mid-term outcomes of computer-assisted total knee arthroplasty.

Authors:  Kazunari Ishida; Tomoyuki Matsumoto; Nobuhiro Tsumura; Seiji Kubo; Atsushi Kitagawa; Takaaki Chin; Tetsuhiro Iguchi; Masahiro Kurosaka; Ryosuke Kuroda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-01-14       Impact factor: 4.342

8.  Comparative experience with intramedullary and extramedullary alignment in total knee arthroplasty.

Authors:  G A Engh; T L Petersen
Journal:  J Arthroplasty       Date:  1990-03       Impact factor: 4.757

9.  Intraoperative impaction of total knee replacements: an explicit finite-element-analysis of principal stresses in ceramic vs. cobalt-chromium femoral components.

Authors:  Daniel Kluess; Wolfram Mittelmeier; Rainer Bader
Journal:  Clin Biomech (Bristol, Avon)       Date:  2010-09-15       Impact factor: 2.063

10.  Comparison of the radiological results between fluoroscopy-assisted and navigation-guided total knee arthroplasty.

Authors:  Young-Bok Jung; Han-Jun Lee; Ho-Joong Jung; Kwang-Sup Song; Jae-Sung Lee; Jae Jun Yang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-12-23       Impact factor: 4.342

View more
  6 in total

1.  The intercondylar notch ceiling: an accurate reference for distal femoral resection in total knee arthroplasty for severely degenerated varus knees.

Authors:  Bing Yue; Jun Wang; You Wang; Mengning Yan; Jun Zhang; Yiming Zeng
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-09-19       Impact factor: 4.342

2.  Significance of asymmetrical posteromedial and posterolateral femoral condylar chamfer cuts in total knee arthroplasty.

Authors:  Harun R Gungor; Nusret Ok; Kadir Agladioglu; Semih Akkaya; Esat Kiter
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-09-26       Impact factor: 4.342

3.  Is a "sulcus cut" technique effective for determining the level of distal femoral resection in total knee arthroplasty?

Authors:  Shinichi Kuriyama; Katsufumi Hyakuna; Satoshi Inoue; Yasuyuki Tanaka; Yasuyuki Tamaki; Hiromu Ito; Shuichi Matsuda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-08-07       Impact factor: 4.342

4.  Intra- and post-operative accuracy assessments of two different patient-specific instrumentation systems for total knee replacement.

Authors:  Andrea Ensini; Antonio Timoncini; Francesco Cenni; Claudio Belvedere; Francesca Fusai; Alberto Leardini; Sandro Giannini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-09-24       Impact factor: 4.342

5.  Radiographic Measurement of Femoral Lateral Bowing and Distal Femoral Condyle Resection Thickness: Variances and Effects on Total Knee Arthroplasty Planning.

Authors:  Pei-Hui Wu; Zhi-Qi Zhang; Ming-Hui Gu; Xiao-Yi Zhao; Yan Kang; Wei-Ming Liao; Ming Fu
Journal:  Chin Med J (Engl)       Date:  2017-11-05       Impact factor: 2.628

6.  Changes in Femoral Posterior Condylar Offset, Tibial Posterior Slope Angle, and Joint Line Height after Cruciate-Retaining Total Knee Arthroplasty.

Authors:  Sang Jun Song; Dae Kyung Bae; Kang Il Kim; Ho Yeon Jeong
Journal:  Knee Surg Relat Res       Date:  2016-02-29
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.