Literature DB >> 3337361

Accuracy of pulse oximetry during arterial oxyhemoglobin desaturation in dogs.

M J Sendak1, A P Harris, R T Donham.   

Abstract

An animal model was developed to evaluate the accuracy of pulse oximetry over a wide range of oxyhemoglobin desaturation. The fractional inspired oxygen concentration was varied from 0.03-1.0 in five anesthetized dogs. One hundred and twelve simultaneous pulse oximeter oxygen saturation measurements (SpO2) and IL 282 CO-Oximeter arterial oxygen saturation (SaO2) measurements were made. Variance of SpO2 was increased for SaO2 less than 22%. Linear regression analysis of the data for SaO2 greater than 22% produced the equation y = 0.93x + 9.8 (r2 = 0.97). The mean difference between SpO2 and SaO2 was +5.5% +/- 4.2% (SD) over the range of 22-100%. Spectral analyses of oxygenated (O2Hb) and reduced (RHb) canine and human hemoglobins were performed. The absorption spectra of canine O2Hb and RHb were nearly identical to those of human O2Hb and RHb. Therefore, 1) SpO2 measurements in dogs at SaO2 greater than 22% are relatively accurate, and 2) hemoglobin absorption characteristics support the contention that such canine pulse oximeter studies can be extrapolated to humans.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3337361     DOI: 10.1097/00000542-198801000-00018

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  10 in total

Review 1.  Pulse oximetry.

Authors:  J F Kelleher
Journal:  J Clin Monit       Date:  1989-01

Review 2.  Pulse oximetry for hypoxemia: a warning to users and manufacturers.

Authors:  S Fanconi
Journal:  Intensive Care Med       Date:  1989       Impact factor: 17.440

3.  Absorption characteristics of human fetal hemoglobin at wavelengths used in pulse oximetry.

Authors:  A P Harris; M J Sendak; R T Donham; M Thomas; D Duncan
Journal:  J Clin Monit       Date:  1988-07

4.  Pulse oximeter signal at various blood flow conditions in an in vitro model.

Authors:  L G Lindberg; M Vegfors; C Lennmarken; P A Oberg
Journal:  Med Biol Eng Comput       Date:  1995-01       Impact factor: 2.602

5.  Comparison of Cerebral Oximeter and Pulse Oximeter Values in the First 72 Hours in Premature, Asphyctic and Healthy Newborns.

Authors:  A Kaya; M Okur; E Sal; E Peker; M Köstü; O Tuncer; E Kırımi
Journal:  West Indian Med J       Date:  2014-09-03       Impact factor: 0.171

6.  A prototype device for standardized calibration of pulse oximeters.

Authors:  C Hornberger; P Knoop; W Nahm; H Matz; E Konecny; H Gehring; R Bonk; H Frankenberger; G Meyfroidt; P Wouters; J Gil-Rodriguez; L Ponz; K Benekos; J Valais; J Avgerinos; A Karoutis; A Ikiades; S Weininger
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

7.  Errors in 14 pulse oximeters during profound hypoxia.

Authors:  J W Severinghaus; K H Naifeh; S O Koh
Journal:  J Clin Monit       Date:  1989-04

8.  Accuracy of pulse oximetry at various haematocrits and during haemolysis in an in vitro model.

Authors:  M Vegfors; L G Lindberg; P A Oberg; C Lennmarken
Journal:  Med Biol Eng Comput       Date:  1993-03       Impact factor: 2.602

9.  Accuracy of pulse oximetry and capnography in healthy and compromised horses during spontaneous and controlled ventilation.

Authors:  Judith Koenig; Wayne McDonell; Alexander Valverde
Journal:  Can J Vet Res       Date:  2003-07       Impact factor: 1.310

10.  Odd haemoglobins in odd-toed ungulates: Impact of selected haemoglobin characteristics of the white rhinoceros (Ceratotherium simum) on the monitoring of the arterial oxygen saturation of haemoglobin.

Authors:  Julia K Reiners; Nadja Hellmann; Juliane Schmidt; Sabine B R Kästner
Journal:  PLoS One       Date:  2019-12-30       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.