Literature DB >> 8324312

Semiautomated method for noise reduction and background phase error correction in MR phase velocity data.

P G Walker1, G B Cranney, M B Scheidegger, G Waseleski, G M Pohost, A P Yoganathan.   

Abstract

Background phase distortion and random noise can adversely affect the quality of magnetic resonance (MR) phase velocity measurements. A semiautomated method has been developed that substantially reduces both effects. To remove the background phase distortion, the following steps were taken: The time standard deviations of the phase velocity images over a cardiac cycle were calculated. Static regions were identified as those in which the standard deviation was low. A flat surface representing an approximation to the background distortion was fitted to the static regions and subtracted from the phase velocity images to give corrected phase images. Random noise was removed by setting to zero those regions in which the standard deviation was high. The technique is demonstrated with a sample set of data in which the in-plane velocities have been measured in an imaging section showing the left ventricular outflow tract of a human left ventricle. The results are presented in vector and contour form, superimposed on the conventional MR angiographic images.

Entities:  

Mesh:

Year:  1993        PMID: 8324312     DOI: 10.1002/jmri.1880030315

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  137 in total

1.  Attenuation of blood flow pulsatility along the Atlas slope: a physiologic property of the distal vertebral artery?

Authors:  T Schubert; M Pansini; O Bieri; C Stippich; S Wetzel; S Schaedelin; A von Hessling; F Santini
Journal:  AJNR Am J Neuroradiol       Date:  2014-11-13       Impact factor: 3.825

2.  Pulmonary and caval flow dynamics after total cavopulmonary connection.

Authors:  K Houlind; E V Stenbøg; K E Sørensen; K Emmertsen; O K Hansen; L Rybro; V E Hjortdal
Journal:  Heart       Date:  1999-01       Impact factor: 5.994

3.  Interdependencies of aortic arch secondary flow patterns, geometry, and age analysed by 4-dimensional phase contrast magnetic resonance imaging at 3 Tesla.

Authors:  Alex Frydrychowicz; Alexander Berger; Alejandro Munoz Del Rio; Maximilian F Russe; Jelena Bock; Andreas Harloff; Michael Markl
Journal:  Eur Radiol       Date:  2011-12-30       Impact factor: 5.315

Review 4.  Four-dimensional flow magnetic resonance imaging in cirrhosis.

Authors:  Zoran Stankovic
Journal:  World J Gastroenterol       Date:  2016-01-07       Impact factor: 5.742

5.  Comparison of 4D flow and 2D velocity-encoded phase contrast MRI sequences for the evaluation of aortic hemodynamics.

Authors:  Emilie Bollache; Pim van Ooij; Alex Powell; James Carr; Michael Markl; Alex J Barker
Journal:  Int J Cardiovasc Imaging       Date:  2016-07-19       Impact factor: 2.357

6.  Four-dimensional phase contrast MRI with accelerated dual velocity encoding.

Authors:  Elizabeth J Nett; Kevin M Johnson; Alex Frydrychowicz; Alejandro Munoz Del Rio; Eric Schrauben; Christopher J Francois; Oliver Wieben
Journal:  J Magn Reson Imaging       Date:  2012-01-26       Impact factor: 4.813

7.  Caval to pulmonary 3D flow distribution in patients with Fontan circulation and impact of potential 4D flow MRI error sources.

Authors:  Kelly Jarvis; Susanne Schnell; Alex J Barker; Michael Rose; Joshua D Robinson; Cynthia K Rigsby; Michael Markl
Journal:  Magn Reson Med       Date:  2018-09-15       Impact factor: 4.668

8.  Improved quantification and mapping of anomalous pulmonary venous flow with four-dimensional phase-contrast MRI and interactive streamline rendering.

Authors:  Albert Hsiao; Ufra Yousaf; Marcus T Alley; Michael Lustig; Frandics Pak Chan; Beverley Newman; Shreyas S Vasanawala
Journal:  J Magn Reson Imaging       Date:  2015-04-24       Impact factor: 4.813

9.  4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and Doppler echocardiography.

Authors:  Maya Gabbour; Susanne Schnell; Kelly Jarvis; Joshua D Robinson; Michael Markl; Cynthia K Rigsby
Journal:  Pediatr Radiol       Date:  2014-12-09

10.  Improved accuracy in flow mapping of congenital heart disease using stationary phantom technique.

Authors:  Thomas A Miller; Andrew B Landes; Adrian M Moran
Journal:  J Cardiovasc Magn Reson       Date:  2009-12-10       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.