Literature DB >> 25914149

Improved quantification and mapping of anomalous pulmonary venous flow with four-dimensional phase-contrast MRI and interactive streamline rendering.

Albert Hsiao1, Ufra Yousaf2, Marcus T Alley2, Michael Lustig3, Frandics Pak Chan2, Beverley Newman2, Shreyas S Vasanawala2.   

Abstract

BACKGROUND: Cardiac MRI is routinely performed for quantification of shunt flow in patients with anomalous pulmonary veins, but can be technically-challenging to perform. Four-dimensional phase-contrast (4D-PC) MRI has potential to simplify this exam. We sought to determine whether 4D-PC may be a viable clinical alternative to conventional 2D phase-contrast MR imaging.
METHODS: With institutional review board approval and HIPAA-compliance, we retrospectively identified all patients with anomalous pulmonary veins who underwent cardiac MRI at either 1.5 Tesla (T) or 3T with parallel-imaging compressed-sensing (PI-CS) 4D-PC between April, 2011 and October, 2013. A total of 15 exams were included (10 male, 5 female). Algorithms for interactive streamline visualization were developed and integrated into in-house software. Blood flow was measured at the valves, pulmonary arteries and veins, cavae, and any associated shunts. Pulmonary veins were mapped to their receiving atrial chamber with streamlines. The intraobserver, interobserver, internal consistency of flow measurements, and consistency with conventional MRI were then evaluated with Pearson correlation and Bland-Altman analysis.
RESULTS: Triplicate measurements of blood flow from 4D-PC were highly consistent, particularly at the aortic and pulmonary valves (cv 2-3%). Flow measurements were reproducible by a second observer (ρ = 0.986-0.999). Direct measurements of shunt volume from anomalous veins and intracardiac shunts matched indirect estimates from the outflow valves (ρ = 0.966). Measurements of shunt fraction using 4D-PC using any approach were more consistent with ventricular volumetric displacements than conventional 2D-PC (ρ = 0.972-0.991 versus 0.929).
CONCLUSION: Shunt flow may be reliably quantified with 4D-PC MRI, either indirectly or with detailed delineation of flow from multiple shunts. The 4D-PC may be a more accurate alternative to conventional MRI.
© 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  flow; pulmonary; shunt; structural; veins

Mesh:

Year:  2015        PMID: 25914149      PMCID: PMC4843111          DOI: 10.1002/jmri.24928

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  27 in total

1.  4D phase-contrast flow cardiovascular magnetic resonance: comprehensive quantification and visualization of flow dynamics in atrial septal defect and partial anomalous pulmonary venous return.

Authors:  Israel Valverde; John Simpson; Tobias Schaeffter; Philipp Beerbaum
Journal:  Pediatr Cardiol       Date:  2010-09-17       Impact factor: 1.655

2.  Sparse MRI: The application of compressed sensing for rapid MR imaging.

Authors:  Michael Lustig; David Donoho; John M Pauly
Journal:  Magn Reson Med       Date:  2007-12       Impact factor: 4.668

3.  Encoding strategies for three-direction phase-contrast MR imaging of flow.

Authors:  N J Pelc; M A Bernstein; A Shimakawa; G H Glover
Journal:  J Magn Reson Imaging       Date:  1991 Jul-Aug       Impact factor: 4.813

4.  Magnetic resonance imaging of complex partial anomalous pulmonary venous return in adults.

Authors:  Barbara L Robinson; Raymond Y Kwong; Praveen K Varma; Mark Wolfe; Gregory Couper
Journal:  Circulation       Date:  2014-01-07       Impact factor: 29.690

Review 5.  Scimitar syndrome: a complex form of anomalous pulmonary venous return.

Authors:  Askin Ali Korkmaz; Cenk Eray Yildiz; Burak Onan; Mustafa Guden; Gurkan Cetin; Kadir Babaoglu
Journal:  J Card Surg       Date:  2011-08-31       Impact factor: 1.620

6.  Fast l₁-SPIRiT compressed sensing parallel imaging MRI: scalable parallel implementation and clinically feasible runtime.

Authors:  Mark Murphy; Marcus Alley; James Demmel; Kurt Keutzer; Shreyas Vasanawala; Michael Lustig
Journal:  IEEE Trans Med Imaging       Date:  2012-02-15       Impact factor: 10.048

7.  Semiautomated method for noise reduction and background phase error correction in MR phase velocity data.

Authors:  P G Walker; G B Cranney; M B Scheidegger; G Waseleski; G M Pohost; A P Yoganathan
Journal:  J Magn Reson Imaging       Date:  1993 May-Jun       Impact factor: 4.813

8.  Improved cardiovascular flow quantification with time-resolved volumetric phase-contrast MRI.

Authors:  Albert Hsiao; Marcus T Alley; Payam Massaband; Robert J Herfkens; Frandics P Chan; Shreyas S Vasanawala
Journal:  Pediatr Radiol       Date:  2011-01-11

9.  Partial anomalous pulmonary venous drainage in young pediatric patients: the role of magnetic resonance imaging.

Authors:  Eugénie Marie-Christine Riesenkampff; Boris Schmitt; Bernhard Schnackenburg; Michael Huebler; Vladimir Alexi-Meskishvili; Roland Hetzer; Felix Berger; Titus Kuehne
Journal:  Pediatr Cardiol       Date:  2009-01-30       Impact factor: 1.655

Review 10.  Partial anomalous pulmonary venous connection to the right side of the heart.

Authors:  R A Gustafson; H E Warden; G F Murray; R C Hill; G E Rozar
Journal:  J Thorac Cardiovasc Surg       Date:  1989-11       Impact factor: 5.209

View more
  10 in total

Review 1.  4D flow MRI applications in congenital heart disease.

Authors:  Judy Rizk
Journal:  Eur Radiol       Date:  2020-09-01       Impact factor: 5.315

Review 2.  Sparse Reconstruction Techniques in Magnetic Resonance Imaging: Methods, Applications, and Challenges to Clinical Adoption.

Authors:  Alice C Yang; Madison Kretzler; Sonja Sudarski; Vikas Gulani; Nicole Seiberlich
Journal:  Invest Radiol       Date:  2016-06       Impact factor: 6.016

3.  4D Flow MRI Quantification of Congenital Shunts: Comparison to Invasive Catheterization.

Authors:  Michael J Horowitz; Daniel F Kupsky; Howaida G El-Said; Laith Alshawabkeh; Seth J Kligerman; Albert Hsiao
Journal:  Radiol Cardiothorac Imaging       Date:  2021-04-01

4.  Quantification of hemodynamics of cerebral arteriovenous malformations after stereotactic radiosurgery using 4D flow magnetic resonance imaging.

Authors:  Shanmukha Srinivas; Tara Retson; Aaron Simon; Jona Hattangadi-Gluth; Albert Hsiao; Nikdokht Farid
Journal:  J Magn Reson Imaging       Date:  2020-12-22       Impact factor: 5.119

5.  Evaluation of atrial septal defects with 4D flow MRI-multilevel and inter-reader reproducibility for quantification of shunt severity.

Authors:  Raluca G Chelu; Michael Horowitz; Dominica Sucha; Isabella Kardys; Delphine Ingremeau; Shreyas Vasanawala; Koen Nieman; Jean-Francois Paul; Albert Hsiao
Journal:  MAGMA       Date:  2018-08-31       Impact factor: 2.310

6.  Accelerated aortic 4D flow cardiovascular magnetic resonance using compressed sensing: applicability, validation and clinical integration.

Authors:  Elisabeth Neuhaus; Kilian Weiss; Rene Bastkowski; Jonas Koopmann; David Maintz; Daniel Giese
Journal:  J Cardiovasc Magn Reson       Date:  2019-10-21       Impact factor: 5.364

7.  Left ventricular global longitudinal strain in bicupsid aortic valve patients: head-to-head comparison between computed tomography, 4D flow cardiovascular magnetic resonance and speckle-tracking echocardiography.

Authors:  Allard T van den Hoven; Sultan Yilmazer; Raluca G Chelu; Roderick W J van Grootel; Savine C S Minderhoud; Lidia R Bons; An M van Berendoncks; Anthonie L Duijnhouwer; Hans-Marc J Siebelink; Annemien E van den Bosch; Ricardo P J Budde; Jolien W Roos-Hesselink; Alexander Hirsch
Journal:  Int J Cardiovasc Imaging       Date:  2020-05-25       Impact factor: 2.357

8.  Right and left ventricular function and flow quantification in pediatric patients with repaired tetralogy of Fallot using four-dimensional flow magnetic resonance imaging.

Authors:  Xiaofen Yao; Liwei Hu; Yafeng Peng; Fei Feng; Rongzhen Ouyang; Weihui Xie; Qian Wang; Aimin Sun; Yumin Zhong
Journal:  BMC Med Imaging       Date:  2021-10-31       Impact factor: 1.930

9.  Pulmonary artery hemodynamic assessment of blood flow characteristics in repaired tetralogy of Fallot patients versus healthy child volunteers.

Authors:  Liwei Hu; Rongzhen Ouyang; Aimin Sun; Qian Wang; Chen Guo; Yafeng Peng; Yan Qin; Yong Zhang; Yang Xiang; Yumin Zhong
Journal:  Quant Imaging Med Surg       Date:  2020-05

10.  Right Pulmonary Vein Atresia in a Mildly Symptomatic Boy: Comprehensive Analysis of Flow Dynamics Using Non-contrast-enhanced 4D Flow MR Imaging.

Authors:  Marie-Luise Kromrey; Hiroaki Kise; Junji Hirose; Masashi Yoshizawa; Takako Toda; Yosuke Kono; Yuto Sunaga; Hisashi Johno; Satoshi Funayama; Hiroshi Onishi; Kevin Johnson; Oliver Wieben; Utaroh Motosugi
Journal:  Magn Reson Med Sci       Date:  2020-01-17       Impact factor: 2.471

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.