Literature DB >> 6333497

Two-dimensional filtering of SPECT images using the Metz and Wiener filters.

M A King, R B Schwinger, P W Doherty, B C Penney.   

Abstract

Two-dimensional filtering, both before and after reconstruction, has been applied to the processing of single photon emission computerized tomographic (SPECT) images. The filters investigated were the count-dependent Metz filter and Wiener filter, both of which automatically adapt to the image being processed. Using a SPECT phantom, with images reconstructed with these filters rather than the ramp, we observed a statistically significant increase (p less than 0.05) in the image contrast for solid Plexiglas spheres, and significant decrease (p less than 0.05) in the percent fractional standard deviation of counts in a region of uniform activity. The adaptability of these filters is demonstrated by a comparison of SPECT acquisitions of the phantom at two different count levels. An example of their application to clinical studies is presented. We conclude that two-dimensional digital image restoration with these techniques can produce a significant increase in SPECT image quality, with a small cost in processing time when these techniques are implemented on an array processor.

Mesh:

Year:  1984        PMID: 6333497

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  25 in total

Review 1.  Digital image processing for clinicians, part II: filtering.

Authors:  Christopher L Hansen
Journal:  J Nucl Cardiol       Date:  2002 Jul-Aug       Impact factor: 5.952

2.  Improved positron emission tomography quantification by Fourier-based restoration filtering.

Authors:  J M Links; J P Leal; H W Mueller-Gaertner; H N Wagner
Journal:  Eur J Nucl Med       Date:  1992

Review 3.  Quantitative analysis in single photon emission tomography (SPET).

Authors:  K A Blokland; H H Reiber; E K Pauwels
Journal:  Eur J Nucl Med       Date:  1992

4.  A filtered backprojection algorithm with characteristics of the iterative landweber algorithm.

Authors:  Gengsheng L Zeng
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

5.  Myocardial perfusion and function single photon emission computed tomography.

Authors:  Christopher L Hansen; Richard A Goldstein; Daniel S Berman; Keith B Churchwell; C David Cooke; James R Corbett; S James Cullom; Seth T Dahlberg; James R Galt; Ravi K Garg; Gary V Heller; Mark C Hyun; Lynne L Johnson; April Mann; Benjamin D McCallister; Raymond Taillefer; R Parker Ward; John J Mahmarian
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

Review 6.  Quantitative myocardial perfusion SPECT.

Authors:  B M Tsui; E C Frey; K J LaCroix; D S Lalush; W H McCartney; M A King; G T Gullberg
Journal:  J Nucl Cardiol       Date:  1998 Sep-Oct       Impact factor: 5.952

7.  Iterative correction method for shift-variant blurring caused by collimator aperture in SPECT.

Authors:  K Ogawa; H Katsu
Journal:  Ann Nucl Med       Date:  1996-02       Impact factor: 2.668

8.  Stimulating technetium-99m cerebral perfusion studies with a three-dimensional Hoffmann brain phantom: collimator and filter selection in SPECT neuroimaging.

Authors:  H J Kim; J S Karp; P D Mozley; S O Yang; D H Moon; H F Kung; H K Lee; A Alavi
Journal:  Ann Nucl Med       Date:  1996-02       Impact factor: 2.668

9.  Imagining guidelines for nuclear cardiology procedures. American Society of Nuclear Cardiology. Myocardial perfusion SPECT protocols.

Authors: 
Journal:  J Nucl Cardiol       Date:  1996 May-Jun       Impact factor: 5.952

10.  Image reconstructions from super-sampled data sets with resolution modeling in PET imaging.

Authors:  Yusheng Li; Samuel Matej; Scott D Metzler
Journal:  Med Phys       Date:  2014-12       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.