Literature DB >> 8229250

Cardiac phantom evaluation of simultaneously acquired dual-isotope rest thallium-201/stress technetium-99m SPECT images.

V J Lowe1, K L Greer, M W Hanson, R J Jaszczak, R E Coleman.   

Abstract

Simultaneously acquired dual-isotope 201Tl/99mTc SPECT studies were performed using cardiac and thoracic phantoms to evaluate the dual-isotope myocardial perfusion technique. Cardiac phantom images representing infarction, viable myocardium and various levels of ischemia were analyzed. Studies with and without attenuating media were performed, and myocardium-to-defect count ratios and defect sizes from dual-isotope SPECT images were compared to myocardium-to-defect count ratios and defect sizes from single-isotope (201Tl and 99mTc) SPECT images. Dual-isotope studies also were interpreted qualitatively. Studies with background activity simulating clinical conditions were performed and interpreted qualitatively. Myocardium-to-defect count ratios from both 99mTc and 201Tl were similar in single-isotope and dual-isotope SPECT images. Thallium-201 and 99mTc defect sizes were decreased slightly (mean +/- s.d., 1.0 +/- 1.7 cc for 201Tl and 0.7 +/- 1.0 cc for 99mTc) on dual studies when compared to single studies but were not statistically significant. Dual-isotope image simulations of normal, ischemic and infarcted and viable myocardium were correctly identified by experienced clinicians in 95% of the cases (21/22). Simultaneous dual-isotope 201Tl/99mTc SPECT imaging of cardiac phantoms produced images that had similar myocardium-to-defect count ratios to those produced using single-isotope techniques and were correctly evaluated on qualitative analysis. Changes in defect size related to dual-isotope imaging were minimal and not qualitatively important.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8229250

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  13 in total

1.  Comparison of simultaneous and sequential SPECT imaging for discrimination tasks in assessment of cardiac defects.

Authors:  C M Trott; J Ouyang; G El Fakhri
Journal:  Phys Med Biol       Date:  2010-11-03       Impact factor: 3.609

2.  Phantom evaluation of simultaneous thallium-201/technetium-99m aquisition in single-photon emission tomography.

Authors:  Z Cao; C C Chen; C Maunoury; L E Holder; T C Abraham; A Tehan
Journal:  Eur J Nucl Med       Date:  1996-11

Review 3.  The maze of myocardial perfusion imaging protocols in 1994.

Authors:  F J Wackers
Journal:  J Nucl Cardiol       Date:  1994 Mar-Apr       Impact factor: 5.952

4.  Quantitative comparison of single-isotope and dual-isotope stress-rest single-photon emission computed tomographic imaging for reversibility of defects.

Authors:  H M Siebelink; D Natale; A J Sinusas; F J Wackers
Journal:  J Nucl Cardiol       Date:  1996 Nov-Dec       Impact factor: 5.952

5.  Simultaneous dual-radionuclide imaging: are the images trustworthy?

Authors:  J M Links
Journal:  Eur J Nucl Med       Date:  1996-10

6.  Preliminary clinical results of photon energy recovery in simultaneous rest Tl-201/stress Tc-99m sestamibi myocardial SPECT.

Authors:  P Hannequin; P Weinmann; J Mas; S Vinot
Journal:  J Nucl Cardiol       Date:  2001 Mar-Apr       Impact factor: 5.952

7.  Simultaneous technetium-99m/thallium-201 SPECT imaging with model-based compensation for cross-contaminating effects.

Authors:  D J Kadrmas; E C Frey; B M Tsui
Journal:  Phys Med Biol       Date:  1999-07       Impact factor: 3.609

8.  Optimization and comparison of simultaneous and separate acquisition protocols for dual isotope myocardial perfusion SPECT.

Authors:  Michael Ghaly; Jonathan M Links; Eric C Frey
Journal:  Phys Med Biol       Date:  2015-06-17       Impact factor: 3.609

9.  Application of three-class ROC analysis to task-based image quality assessment of simultaneous dual-isotope myocardial perfusion SPECT (MPS).

Authors:  Xin He; Xiyun Song; Eric C Frey
Journal:  IEEE Trans Med Imaging       Date:  2008-11       Impact factor: 10.048

10.  Sympathetic re-innervation after heart transplantation: dual-isotope neurotransmitter scintigraphy, norepinephrine content and histological examination.

Authors:  C Guertner; B J Krause; H Klepzig; G Herrmann; S Lelbach; E K Vockert; A Hartmann; F D Maul; T W Kranert; E Mutschler
Journal:  Eur J Nucl Med       Date:  1995-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.