Literature DB >> 8167489

Effect of measuring ambulatory blood pressure on sleep and on blood pressure during sleep.

R J Davies1, N E Jenkins, J R Stradling.   

Abstract

OBJECTIVE: To assess whether recording of ambulatory blood pressure at night causes arousal from sleep and a change in the continuous blood pressure recorded simultaneously.
DESIGN: Repeated measurement of blood pressure with two ambulatory blood pressure machines (Oxford Medical ABP and A&D TM2420) during continuous measurement of beat to beat blood pressure and continuous electroencephalography.
SETTING: Sleep research laboratory.
SUBJECTS: Six normal subjects. MAIN OUTCOME MEASURES: The duration of electroencephalographic arousal and the beat to beat changes in blood pressure produced by the measurement of ambulatory blood pressure; the size of any changes that this arousal and change in blood pressure produced in the blood pressure recorded by the ambulatory machine.
RESULTS: Both ambulatory blood pressure machines caused arousal from sleep: the mean duration of arousal was 16 seconds (95% range 0-202) with the ABP and 8 seconds (0-73) with the TM2420. Both also caused a rise in beat to beat blood pressure. During non-rapid eye movement sleep, this rise led to the ABP machine overestimating the true systolic blood pressure during sleep by a mean of 10 (SD 14.8) mm Hg and the TM2420 by a mean of 6.3 (8.2) mm Hg. On average, diastolic pressure was not changed, but measurements in individual subjects changed by up to 23 mm Hg. These changes varied in size among subjects and stages of sleep and were seen after measurements that did not cause any electroencephalographic arousal.
CONCLUSIONS: Ambulatory blood pressure machines cause appreciable arousal from sleep and therefore alter the blood pressure that they are trying to record. This effect should be taken into account when recordings of blood pressure at night are interpreted in clinical work and epidemiological research.

Entities:  

Mesh:

Year:  1994        PMID: 8167489      PMCID: PMC2539985          DOI: 10.1136/bmj.308.6932.820

Source DB:  PubMed          Journal:  BMJ        ISSN: 0959-8138


  13 in total

1.  THE ELECTRODERMOGRAM (TARCHANOFF EFFECT) DURING SLEEP.

Authors:  R J BROUGHTON; R POIRE; C A TASSINARI
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1965-06

2.  Hypoxemia alone does not explain blood pressure elevations after obstructive apneas.

Authors:  J Ringler; R C Basner; R Shannon; R Schwartzstein; H Manning; S E Weinberger; J W Weiss
Journal:  J Appl Physiol (1985)       Date:  1990-12

3.  Comparison of finger and intra-arterial blood pressure monitoring at rest and during laboratory testing.

Authors:  G Parati; R Casadei; A Groppelli; M Di Rienzo; G Mancia
Journal:  Hypertension       Date:  1989-06       Impact factor: 10.190

4.  Continuous, real-time, noninvasive monitor of blood pressure: Penaz methodology applied to the finger.

Authors:  R D Boehmer
Journal:  J Clin Monit       Date:  1987-10

5.  The orienting reflex during waking and sleeping.

Authors:  L C Johnson; A Lubin
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1967-01

6.  Effects of blood-pressure measurement by the doctor on patient's blood pressure and heart rate.

Authors:  G Mancia; G Bertinieri; G Grassi; G Parati; G Pomidossi; A Ferrari; L Gregorini; A Zanchetti
Journal:  Lancet       Date:  1983-09-24       Impact factor: 79.321

7.  Dippers and non-dippers.

Authors:  E O'Brien; J Sheridan; K O'Malley
Journal:  Lancet       Date:  1988-08-13       Impact factor: 79.321

8.  Evaluation of two prototype devices producing noninvasive, pulsatile, calibrated blood pressure measurement from a finger.

Authors:  N T Smith; K H Wesseling; B de Wit
Journal:  J Clin Monit       Date:  1985-01

9.  Circadian blood pressure changes and left ventricular hypertrophy in essential hypertension.

Authors:  P Verdecchia; G Schillaci; M Guerrieri; C Gatteschi; G Benemio; F Boldrini; C Porcellati
Journal:  Circulation       Date:  1990-02       Impact factor: 29.690

10.  The prognostic value of ambulatory blood pressures.

Authors:  D Perloff; M Sokolow; R Cowan
Journal:  JAMA       Date:  1983-05-27       Impact factor: 56.272

View more
  25 in total

1.  Non-invasive monitoring of central blood pressure by electrical impedance tomography: first experimental evidence.

Authors:  Josep Solà; Andy Adler; Arnoldo Santos; Gerardo Tusman; Fernando Suárez Sipmann; Stephan H Bohm
Journal:  Med Biol Eng Comput       Date:  2011-03-15       Impact factor: 2.602

Review 2.  Ambulatory blood pressure monitoring: a guide for general practitioners.

Authors:  N Prasad; C Isles
Journal:  BMJ       Date:  1996-12-14

3.  Nocturnal ambulatory blood pressure measurement.

Authors:  R J Davies; J R Stradling
Journal:  BMJ       Date:  1994 Aug 20-27

4.  Nocturnal ambulatory blood pressure measurement.

Authors:  A Shennan; M De Swiet; A Halligan
Journal:  BMJ       Date:  1994-06-18

5.  Validity of transit time-based blood pressure measurements in patients with and without heart failure or pulmonary arterial hypertension across different breathing maneuvers.

Authors:  Sara Becker; Jens Spiesshoefer; Tobias Brix; Izabela Tuleta; Michael Mohr; Michele Emdin; Matthias Boentert; Alberto Giannoni
Journal:  Sleep Breath       Date:  2019-05-02       Impact factor: 2.816

6.  Effect of Supplemental Oxygen on Blood Pressure in Obstructive Sleep Apnea (SOX). A Randomized Continuous Positive Airway Pressure Withdrawal Trial.

Authors:  Chris D Turnbull; Dushendree Sen; Malcolm Kohler; Nayia Petousi; John R Stradling
Journal:  Am J Respir Crit Care Med       Date:  2019-01-15       Impact factor: 21.405

7.  Hypertension and obstructive sleep apnea in Caucasian children.

Authors:  Valerie Kirk; Julian Midgley; Michael Giuffre; Paul Ronksley; Alberto Nettel-Aguirre; Abdulla Al-Shamrani
Journal:  World J Cardiol       Date:  2010-08-26

8.  Nasal CPAP reduces systemic blood pressure in patients with obstructive sleep apnoea and mild sleepiness.

Authors:  D S Hui; K W To; F W Ko; J P Fok; M C Chan; J C Ngai; A H Tung; C W Ho; M W Tong; C-C Szeto; C-M Yu
Journal:  Thorax       Date:  2006-08-23       Impact factor: 9.139

9.  The effect of measuring ambulatory blood pressure on nighttime sleep and daytime activity--implications for dipping.

Authors:  Rajiv Agarwal; Robert P Light
Journal:  Clin J Am Soc Nephrol       Date:  2009-12-17       Impact factor: 8.237

10.  Validation of blood pressure monitoring using pulse transit time in heart failure patients with Cheyne-Stokes respiration undergoing adaptive servoventilation therapy.

Authors:  Jens Spießhöfer; Jessica Heinrich; Thomas Bitter; Christina Efken; Roman Lehmann; Siegfried Eckert; Dieter Horstkotte; Olaf Oldenburg
Journal:  Sleep Breath       Date:  2013-09-24       Impact factor: 2.816

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.