Non-invasive monitoring of central blood pressure by electrical impedance tomography: first experimental evidence.

Josep Solà1, Andy Adler, Arnoldo Santos, Gerardo Tusman, Fernando Suárez Sipmann, Stephan H Bohm.   

Abstract

There is a strong clinical demand for devices allowing continuous non-invasive monitoring of central blood pressure (BP). In the state of the art a new family of techniques providing BP surrogates based on the measurement of the so-called pulse wave velocity (PWV) has been proposed, eliminating the need for inflation cuffs. PWV is defined as the velocity at which pressure pulses propagate along the arterial wall. However, no technique to assess PWV within central arteries in a fully unsupervised manner has been proposed so far. In this pilot study, we provide first experimental evidence that electrical impedance tomography (EIT) is capable of measuring pressure pulses directly within the descending aorta. To obtain a wide range of BP values, we administrated noradrenalin and nitroglycerine to an anesthetized pig under mechanical ventilation. An arterial line was inserted into the ascending aorta for measuring reference BP. EIT images were generated from 32 impedance electrodes placed around the chest at the level of the axilla. Regions of Interest (ROI) such as the descending aorta and the lungs were automatically identified by a novel time-based processing algorithm as the respective EIT pixels representing these structures. The correct positions of these ROIs were confirmed by bolus injections of highly conductive concentrated saline into the right heart and into the ascending aorta. Aortic pulse transit time (PTT) values were determined as the delay between the opening of the aortic valve (obtained from arterial line) and the arrival of pressure pulses at the aortic ROI within the EIT plane. For 11 experimental conditions, with mean BP ranging from 73 to 141 mmHg, strongly significant correlation (r = -0.97, P < 0.00001) between central BP and aortic PTT was observed, suggesting that EIT-derived aortic PTT is a potential non-invasive surrogate of central BP.

Entities:  

Mesh:

Year:  2011        PMID: 21404079     DOI: 10.1007/s11517-011-0753-z

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  6 in total

1.  Expert consensus document on arterial stiffness: methodological issues and clinical applications.

Authors:  Stephane Laurent; John Cockcroft; Luc Van Bortel; Pierre Boutouyrie; Cristina Giannattasio; Daniel Hayoz; Bruno Pannier; Charalambos Vlachopoulos; Ian Wilkinson; Harry Struijker-Boudier
Journal:  Eur Heart J       Date:  2006-09-25       Impact factor: 29.983

2.  Parametric estimation of pulse arrival time: a robust approach to pulse wave velocity.

Authors:  Josep Solà; Rolf Vetter; Philippe Renevey; Olivier Chételat; Claudio Sartori; Stefano F Rimoldi
Journal:  Physiol Meas       Date:  2009-06-03       Impact factor: 2.833

Review 3.  Time domain analysis of the arterial pulse in clinical medicine.

Authors:  Michael F O'Rourke
Journal:  Med Biol Eng Comput       Date:  2008-07-15       Impact factor: 2.602

4.  Effect of measuring ambulatory blood pressure on sleep and on blood pressure during sleep.

Authors:  R J Davies; N E Jenkins; J R Stradling
Journal:  BMJ       Date:  1994-03-26

5.  Regional lung perfusion as determined by electrical impedance tomography in comparison with electron beam CT imaging.

Authors:  Inéz Frerichs; José Hinz; Peter Herrmann; Gerald Weisser; Günter Hahn; Michael Quintel; Gerhard Hellige
Journal:  IEEE Trans Med Imaging       Date:  2002-06       Impact factor: 10.048

6.  European Society of Hypertension guidelines for blood pressure monitoring at home: a summary report of the Second International Consensus Conference on Home Blood Pressure Monitoring.

Authors:  Gianfranco Parati; George S Stergiou; Roland Asmar; Grzegorz Bilo; Peter de Leeuw; Yutaka Imai; Kazuomi Kario; Empar Lurbe; Athanasios Manolis; Thomas Mengden; Eoin O'Brien; Takayoshi Ohkubo; Paul Padfield; Paolo Palatini; Thomas Pickering; Josep Redon; Miriam Revera; Luis M Ruilope; Andrew Shennan; Jan A Staessen; Andras Tisler; Bernard Waeber; Alberto Zanchetti; Giuseppe Mancia
Journal:  J Hypertens       Date:  2008-08       Impact factor: 4.844

  6 in total
  8 in total

1.  Noninvasive pulmonary artery pressure monitoring by EIT: a model-based feasibility study.

Authors:  Martin Proença; Fabian Braun; Josep Solà; Jean-Philippe Thiran; Mathieu Lemay
Journal:  Med Biol Eng Comput       Date:  2016-09-17       Impact factor: 2.602

2.  The Nightingale Prize for best MBEC paper in 2011.

Authors:  Jos A E Spaan
Journal:  Med Biol Eng Comput       Date:  2012-11-25       Impact factor: 2.602

3.  A feasibility study of magnetic resonance electrical impedance tomography for prostate cancer detection.

Authors:  Yang Liu; Yingchun Zhang
Journal:  Physiol Meas       Date:  2014-03-12       Impact factor: 2.833

4.  Modelling of an oesophageal electrode for cardiac function tomography.

Authors:  J Nasehi Tehrani; C Jin; A L McEwan
Journal:  Comput Math Methods Med       Date:  2012-03-15       Impact factor: 2.238

5.  Changing trends of hemodynamic monitoring in ICU - from invasive to non-invasive methods: Are we there yet?

Authors:  Shubhangi Arora; Preet Mohinder Singh; Basavana G Goudra; Ashish C Sinha
Journal:  Int J Crit Illn Inj Sci       Date:  2014-04

6.  Freezing resistance evaluation of rose stems during frost dehardening using electrical impedance tomography.

Authors:  Juan Zhou; Ruijuan Gong; Ji Qian; Yang Liu; Gang Zhang
Journal:  BMC Plant Biol       Date:  2021-04-26       Impact factor: 4.215

7.  A 3D visualization method for bladder filling examination based on EIT.

Authors:  Wei He; Peng Ran; Zheng Xu; Bing Li; Song-nong Li
Journal:  Comput Math Methods Med       Date:  2012-12-31       Impact factor: 2.238

8.  Accuracy and reliability of noninvasive stroke volume monitoring via ECG-gated 3D electrical impedance tomography in healthy volunteers.

Authors:  Fabian Braun; Martin Proença; Andy Adler; Thomas Riedel; Jean-Philippe Thiran; Josep Solà
Journal:  PLoS One       Date:  2018-01-26       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.