Literature DB >> 8141064

Comparison of lesion enhancement on spin-echo and gradient-echo images.

P M Chappell1, N J Pelc, T K Foo, G H Glover, S P Haros, D R Enzmann.   

Abstract

PURPOSE: To compare lesion enhancement after injection of gadopentetate dimeglumine on spin-echo and gradient-echo T1-weighted images.
METHODS: A total of 48 contrast-enhancing intracranial lesions were evaluated using a spin-echo and two gradient-echo T1-weighted pulse sequences. Percent contrast, contrast-to-noise, and signal-to-noise measurements were made on the spin-echo T1-weighted, three-dimensional gradient-echo, and multiplanar gradient-echo sequences.
RESULTS: The measurements were somewhat different for the following categories of lesions: extraaxial, intraaxial with edema, and intraaxial without edema. The latter group provided the greatest diagnostic challenge: three of 19 such lesions 1 cm in size or smaller could not be identified on three-dimensional gradient-echo images, and one could not be identified on multi-planar gradient-echo images. The spin-echo T1-weighted sequence demonstrated significantly higher percent contrast (P < .05) and greater contrast to noise (P < .03) than either gradient-echo sequence for these small intraaxial lesions without edema. For extraaxial and intraaxial lesions with edema, percent C was similar for spin-echo T1-weighted and three-dimensional gradient-echo images, while contrast to noise was greater for spin-echo T1-weighted images. This reflected greater tissue noise with gradient-echo sequences.
CONCLUSION: The T1-weighted spin-echo sequence was preferred for detecting the full spectrum of contrast-enhancing lesions of the central nervous system.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8141064      PMCID: PMC8332096     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  15 in total

1.  Brain Tumor-Enhancement Visualization and Morphometric Assessment: A Comparison of MPRAGE, SPACE, and VIBE MRI Techniques.

Authors:  L Danieli; G C Riccitelli; D Distefano; E Prodi; E Ventura; A Cianfoni; A Kaelin-Lang; M Reinert; E Pravatà
Journal:  AJNR Am J Neuroradiol       Date:  2019-06-20       Impact factor: 3.825

2.  Contrast enhancement of intracranial lesions at 1.5 T: comparison among 2D spin echo, black-blood (BB) Cube, and BB Cube-FLAIR sequences.

Authors:  SungWoon Im; Ryuichiro Ashikaga; Yukinobu Yagyu; Tetsuya Wakayama; Mitsuharu Miyoshi; Tomoko Hyodo; Izumi Imaoka; Seishi Kumano; Kazunari Ishii; Takamichi Murakami
Journal:  Eur Radiol       Date:  2015-05-01       Impact factor: 5.315

3.  MS lesions are better detected with 3D T1 gradient-echo than with 2D T1 spin-echo gadolinium-enhanced imaging at 3T.

Authors:  A Crombé; M Saranathan; A Ruet; M Durieux; E de Roquefeuil; J C Ouallet; B Brochet; V Dousset; T Tourdias
Journal:  AJNR Am J Neuroradiol       Date:  2014-11-06       Impact factor: 3.825

4.  Comparison of lesion enhancement between BB Cube and 3D-SPGR images for brain tumors with 1.5-T magnetic resonance imaging.

Authors:  Hirokazu Hasegawa; Ryuichiro Ashikaga; Kaoru Okajima; Tetsuya Wakayama; Mitsuharu Miyoshi; Yasumasa Nishimura; Takamichi Murakami
Journal:  Jpn J Radiol       Date:  2017-05-24       Impact factor: 2.374

Review 5.  The detectability of brain metastases using contrast-enhanced spin-echo or gradient-echo images: a systematic review and meta-analysis.

Authors:  Chong Hyun Suh; Seung Chai Jung; Kyung Won Kim; Junhee Pyo
Journal:  J Neurooncol       Date:  2016-06-20       Impact factor: 4.130

6.  Consensus recommendations for a standardized brain tumor imaging protocol for clinical trials in brain metastases.

Authors:  Timothy J Kaufmann; Marion Smits; Jerrold Boxerman; Raymond Huang; Daniel P Barboriak; Michael Weller; Caroline Chung; Christina Tsien; Paul D Brown; Lalitha Shankar; Evanthia Galanis; Elizabeth Gerstner; Martin J van den Bent; Terry C Burns; Ian F Parney; Gavin Dunn; Priscilla K Brastianos; Nancy U Lin; Patrick Y Wen; Benjamin M Ellingson
Journal:  Neuro Oncol       Date:  2020-06-09       Impact factor: 12.300

7.  Usefulness of the Delay Alternating with Nutation for Tailored Excitation Pulse with T1-Weighted Sampling Perfection with Application-Optimized Contrasts Using Different Flip Angle Evolution in the Detection of Cerebral Metastases: Comparison with MPRAGE Imaging.

Authors:  D Kim; Y J Heo; H W Jeong; J W Baek; J-Y Han; J Y Lee; S-C Jin; H J Baek
Journal:  AJNR Am J Neuroradiol       Date:  2019-08-01       Impact factor: 3.825

8.  Usefulness of contrast-enhanced T1-weighted sampling perfection with application-optimized contrasts by using different flip angle evolutions in detection of small brain metastasis at 3T MR imaging: comparison with magnetization-prepared rapid acquisition of gradient echo imaging.

Authors:  Y Kato; S Higano; H Tamura; S Mugikura; A Umetsu; T Murata; S Takahashi
Journal:  AJNR Am J Neuroradiol       Date:  2009-02-12       Impact factor: 3.825

9.  Comparison of contrast-enhanced modified T1-weighted 3D TSE black-blood and 3D MP-RAGE sequences for the detection of cerebral metastases and brain tumours.

Authors:  N N Kammer; E Coppenrath; K M Treitl; H Kooijman; O Dietrich; T Saam
Journal:  Eur Radiol       Date:  2015-09-03       Impact factor: 5.315

10.  Cerebral staging of lung cancer: is one single contrast-enhanced T1-weighted three-dimensional gradient-echo sequence sufficient?

Authors:  Mickaël Ohana; Mi-Young Jeung; Gauthier Bazille; Catherine Roy
Journal:  Neuroradiology       Date:  2014-05-15       Impact factor: 2.804

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.